Features
• NIST Traceable Calibration
Certificates
• FDA 21 CFR Part 11 Compliant
• IQ/OQ/PQ Validation Protocols
• Splash Proof Cryo-Temp Data Logger
• -86 °C to +35 °C Temperature Range
• 0.1 °C Resolution and ±1.0 °C
Accuracy
• 1 Year Battery Life at -80 °C
• User-Programmable Temperature
Alarms with LED’s (OK, Warn, and
Alarm)
• Hardware and Software Password
Protection
• Simultaneous Starts, Memory Wrap
• User-Programmable Start Times,
Sample Intervals, Logger
Descriptions, Unique ID’s
MadgeTech’s Ultra Low Temperature Freezer Validation System can measure and log data as
low as -86 °C. It can be placed in small and large freezers of varying configurations.
Available with 9, 15
or a custom number
of Cryo-Temps
Applications
• Ultralow Freezer Validation
• Ultralow Freezer Mapping
• Ultralow Freezer Stabilization Studies
• Temperature Surveys
- Reveal stratification of air
- Reveal hot spots
- Reveal anomalies in chilling systems
The system provides a complete stand-alone temperature mapping and validation solution
for freezers to ensure uniform storage and testing conditions. The ULT90 includes a USB
docking station with 6 feet of cable (IFC300), the Cryo-Temp data logger, and MadgeTech’s
FDA 21 CFR Part 11 Secure Software and IQ/OQ/PQ validation protocols. For larger freezers,
loggers can be plotted in one graph to show variances in different parts of the freezer. Finally, as
failure to monitor external freezer temperatures may invalidate internal freezer temperatures, an
MADGETECH DATA LOGGER SOFTWARE
A
Key
A Graph View
B Tabular Data View
C Statistics
D Digital Calibration
E Copy to Excel®
B
C
Software Features:
E
D
• Multiple graph overlay
• Statistics
• Digital calibration
• Zoom in/ zoom out
• Lethality equations (F0, PU)
• Mean Kinetic Temperature
• Full time zone support
• Data annotation
• Min./Max./Average lines
• Data table view
• Automatic report generation
• Summary view
• Multilingual
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
ULT90 SPECIFICATIONS* (CRYO-TEMP DATA LOGGER)
TEMPERATURE
Sensor: NTC Thermistor
Measurement Range:
-86 °C to +35 °C recommended, may be used up to +55 °C
Resolution: 0.1 °C
Calibrated Accuracy: ±1.0 °C
Specified Accuracy Range: -80 °C to 0 °C
Memory:
Reading Rate:
32,767 readings; software configurable memory wrap
5 seconds to 30 minutes, selectable in software
Software programmable
Start Modes:
immediate start, delay start up to 30 days in advance or manual start with magnetic switch.
• Software programmable high and low alarm limits and high and low
Temperature Alarm:
warn limits
• Each setpoint may be individually enabled or disabled
Software programmable time delay for warn/alarm limits. Logger will not
Alarm Delay:
indicate out of range status until the temperature has been out of range for a set period of time.
• Green: Indicates safe conditions during logging
Status Indicators:
• Yellow: Indicates warn limits have been exceeded
• Red: Indicate alarm criteria (limits/ delay) have been exceeded
An optional password may be programmed
Password Protection:
into the device to restrict access to configura­tion options. Data may be read out without the password.
Calibration:
Digital calibration is available to the user through software
Calibration Date: Automatically recorded within device
*Battery Type:
Battery Life:
Time Accuracy:
3.6V lithium battery (LTC-7PN),
*Must be sent to MadgeTech for battery replacement.
2 years typical @ 25 °C, 1 min. reading intervals 1 year typical @ –80 °C, 1 min. reading intervals
±2 minutes/month max. at 20 °C to 30 °C ±5 minutes/month max at –80 °C
Data Format: Date and time stamped °C, °F, K, °R
Computer Interface: USB docking station to PC (IFC300) 38,400 baud
Software:
Operating Environment:
XP SP3/Vista/Windows 7 Not Compatible with 64 bit systems
-86 °C to +35 °C (may be used up to +55 °C); 0 to 100% RH
Dimensions: 3.3” x 2.1” x 0.4” (83 mm x 54 mm x 11 mm)
Ingress Protection/IP
Rating:
IP64 (splash resistant, not submersible)
Enclosure: ABS plastic, white, polycarbonate labeling
1.4 oz (40 g) each
Weight:
Total for packages: ULT90-9 - 50.9 oz (1443 g) ULT90-15 - 59.3 oz (1681 g)
Compliance: CE
BATTERY WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT RECHARGE,
DISASSEMBLE, HEAT ABOVE 212 ºF, INCINERATE OR EXPOSE CONTENTS TO WATER.
*SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC WARRANTY REMEDY
LIMITATIONS APPLY. CALL 1-603-456-2011 OR GO TO WWW.MADGETECH.COM FOR DETAILS.
ORDERING INFORMATION
MODEL DESCRIPTION PRICE (U.S.)
ULT90-9
ULT90-15
ULT90-Custom
Includes 9 Cryo-Temp data loggers with NIST Traceable calibration certificates, IFC300 docking station, MadgeTech’s FDA 21 CFR Part 11 Secure Software and IQ/OQ/PQ validation protocols.
Includes 15 Cryo-Temp data loggers with NIST Traceable calibration certificates, IFC300 docking station, MadgeTech’s FDA 21 CFR Part 11 Secure Software and IQ/OQ/PQ validation protocols.
Includes a custom number of Cryo-Temp data loggers with NIST Traceable calibration certificates, IFC300 docking station, MadgeTech’s FDA 21 CFR Part 11 Secure Software and IQ/OQ/PQ validation protocols.
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
$3,200
$4,500
Call for Pricing
Temperature
ASK ABOUT OUR OTHER
DATA
LOGGERS
DOC-1198009-00 REV 4 2014.03.14
Humidity
Pressure
pH
Level
Shock
LCD Display
Pulse/Event/State
Current Voltage
Wireless
Intrinsically Safe
Spectral Vibration
Motion
Loading...