THERM•A•LERT-P
TEMPERATURE MONITORING AND ALARMING
SYSTEM WITH WIRELESS TWO-WAY
COMMUNICATION
Features
• Wireless Two-Way Communication
• Precision RTD Sensing Element
• View Data in Real Time
• 2 Year Battery Life
• Battery Life Indicator
• Field Upgradeable
Benefits
• Fast Installation
• Minimal Long-Term Maintenance
• Full Communication From One PC
Applications
• Refrigerator/Freezer Monitoring
• Calibration chamber monitoring
• Laboratory monitoring
• Hospitals
• Blood Banks
• HVAC
The MadgeTech Therm•A•Lert-P is a temperature monitoring and alarming
system, designed specifically for laboratories, warehouses and other environments where temperature monitoring is critical. The system can be used
to monitor a single location, or expanded to monitor hundreds of locations
over a broad area (additional MadgeTech wireless loggers and transceivers
may be required).
The Therm•A•Lert-P provides real time wireless, or wired, notification of
temperature. The data logger features user programmable alarms that can
be configured to send a message via text message (standard SMS rates
apply), on-screen alarm and/or via e-mail if an alarm condition is met. The
standard Therm•A•Lert-P includes an RTD probe with a 9 ft lead wire and a
4.5 in probe sheath.
The Therm•A•Lert-P device is equipped with two-way wireless communication. MadgeTech wireless systems offer a flexible and robust integration for
many applications. One PC can provide control and communication to all
the wireless loggers within range, or the system can be divided into smaller subnets
(using a different RF channel). In addition to the data being transmitted wirelessly,
the Therm•A•Lert-P also stores each reading to non-volatile internal memory for a
secure backup. Customers can set up automatic archiving preferences, ensuring all
data is saved and retained to comply with federal regulations.
The Therm•A•Lert-P probe can be mounted inside an ethylene glycol bottle. When
placed in a chamber, the temperature of the ethylene glycol is measured rather
than air temperature. This more accurately represents the temperature of the
contents inside the chamber, and prevents false alarm triggers when the chamber
door is opened and closed. The glycol bottles are available in 30 ml, 60 ml and
250 ml sizes.
Ethylene glycol bottle (optional)
MADGETECH DATA LOGGER SOFTWARE
A
Key
A Graph View
B Connected Devices
C Battery Life Indicator
D Digital Calibration
E Copy to Excel®
B
C
E
D
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
Software Features:
• Multiple graph overlay
• Statistics
• Digital calibration
• Zoom in/ zoom out
• Lethality equations (F0, PU)
• Mean Kinetic Temperature
• Full time zone support
• Data annotation
• Min./Max./Average lines
• Data table view
• Automatic report generation
• Summary view
• Multilingual
THERM•A•LERT-P SPECIFICATIONS*
Temperature**
Probe Temperature
Range:
Lead Wire Range: -200 ºC to +200 ºC (-328 ºF to +392 ºF)
Glycol Bottle
(optional) Range:
Resolution: 0.01 °C (0.018 °F)
Probe Calibrated
Accuracy:
-200 °C to +260 °C (-328 °F to +500 °F)
-50 ºC to +80 ºC (-58 ºF to +176 ºF)
±0.1 °C/±0.18 °F
(-20 °C to +80 °C/-4 °F to +176 °F)
±0.5 °C/±0.9 °F (outside of specified range)
Wireless
RF Frequency:
Maximum Output
Power:
Receiver Sensitivity
(RFC1000):
Transmission Distance
(to data loggers)
Transmission Distance
(to other RFC1000’s)
2.45 GHz IEEE 802.15.4 ultra-low power wireless transceiver
with fully bi-directional communication
Band: ISM band 2.405-2.48 GHz
+0 dBm typical
-95 dBm typical
• RFC1000, RFC1000-CE & RFC1000-IP69K
2,000 ft max. outdoors - line of sight unobstructed
500 ft max. indoors - typical urban environment
• RFC1000
4,000 ft max. outdoors - line of sight unobstructed
1,000 ft max. indoors - typical urban environment
• RFC1000-CE
2,500 ft max. outdoors - line of sight unobstructed
700 ft max. indoors - typical urban environment
• RFC1000-IP69K
4,000 ft max. outdoors - line of sight unobstructed
1,000 ft max. indoors - typical urban environment
ORDERING INFORMATION
General
Reading Rate: 1 reading every 2 seconds up to 1 reading every 24 hours
Memory: 30,000 readings; software configurable memory wrap
Wrap Around: Yes
Start Modes: Immediate start
Calibration: Digital calibration through software
Calibration Date: Automatically recorded within device
Battery Type: 3.6V lithium battery included; user replaceable
Battery Life: 2 years typical
Data Format: Date and time stamped ºC, ºF, K, ºR
Time Accuracy: ±1 minute / month (at 25 °C)
Computer Interface:
Software: XP SP3/Vista/Windows 7/Windows 8
Operating Environment:
Dimensions:
Enclosure Material: ABS Plastic
Approvals: US (FCC), CA (IC), CE
*SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC WARRANTY REMEDY
LIMITATIONS APPLY. CALL 1-603-456-2011 OR GO TO WWW.MADGETECH.COM FOR DETAILS.
**Temperature specifications based on ideal 100 Ω Pt RTD compliant with IEC 751 (1983) and ITS90, 5000 Ω.
BATTERY WARNING: Do not recharge, disassemble, heat above 100 °C (212 °F), incinerate or expose
contents to water. Vent, rupture or explosion may result and cause severe burns.
USB to mini USB, 250,000 baud for standalone operation
or RFC1000 required for wireless operation
-20 ºC to +80 ºC (-4 ºF to +176 ºF),
0 %RH to 95 %RH non-condensing
Programmable high and low limits for temperature.
Alarm:
Alarm is activated when temperature reaches or exceeds
set limits.
• Data Logger:
2.2 in x 5.0 in x 1.3 in (55 mm x 127 mm x 33 mm)
• Wire: 9 ft
• Probe: 3/16 in dia x 4.5 in
Glycol bottle:
• 30 ml: 2.5 in x 1.5 in x 1.5 in
(63 mm x 38 mm x 38 mm)
• 60 ml: 3.3 in x 1.6 in x 1.6 in
(84 mm x 41 mm x 41 mm)
• 250 ml: 5.7 in x 2.3 in x 2.3 in
(145 mm x 58 mm x 58 mm)
MODEL DESCRIPTION
THERM•A•LERT-P Temperature data logger with wireless transceiver equipped with precision RTD probe
THERM•A•LERT-P-30 Temperature data logger with wireless transceiver equipped with RTD probe and 30 ml glycol bottle
THERM•A•LERT-P-60 Temperature data logger with wireless transceiver equipped with RTD probe and 60 ml glycol bottle
THERM•A•LERT-P-250 Temperature data logger with wireless transceiver equipped with RTD probe and 250 ml glycol bottle
RFC1000 Wireless RF transceiver/repeater. USB to mini USB adapter & power supply included
RFC1000-CE Wireless RF transceiver/repeater, CE approved for Europe. USB to mini USB adapter & power supply included
RFC1000-IP69K Wireless RF transceiver/repeater, splash proof with an IP69K rating. USB to mini USB adapter included
Calibration Certificate Calibration Certificate available for data logger
TL-5104 Replacement battery for Therm•A•lert-P
For Quantity Discounts call (603) 456-2011 or email sales@madgetech.com
Countries approved for use, purchase and distribution of the Therm•A•Lert-P:
Australia, Austria, Belgium, Bulgaria, Canada, Chile, Columbia, Croatia, Cyprus, Czech Republic, Denmark, Ecuador, Estonia, Finland, France, Germany, Greece, Honduras, Hungary,
Iceland, Ireland, Israel, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Mexico, New Zealand, Norway, Peru, Poland, Portugal, Romania, Saudi Arabia, Singapore, Slovakia, Slovenia,
South Africa, Spain, Sweden, Switzerland, Thailand, The Netherlands, Turkey, United Kingdom, United States, Venezuela, Vietnam
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
DOC 1225009-00 REV 9 2016.09.15