Features
• 10 Year Battery Life
• 1 Second Reading Rate
• Multiple Start/Stop Function
• Ultra High Speed Download
• 1,000,000 Reading Storage
Capacity
• Memory Wrap
• Battery Life Indicator
• Optional Password Protection
• Programmable High and Low Alarms
• Field Upgradeable
Benefits
• Simple Setup and Installation
• Minimal Long-Term Maintenance
• Long-Term Field Deployment
Applications
• Process Validation
• Dry Ice Shipments and Storage
• Oven Profiling
• HVAC
• Implement HACCP Programs
• General Purpose Temperature
Recording
The TC101A temperature data logger, is a compact
versatile device to be used with thermocouple probes
for accurate temperature monitoring and profiling.
This data logger is an ideal and affordable solution
for applications such as HVAC studies, oven profiling,
dry-ice shipments, process validation and many general
purpose temperature monitoring applications.
Compatible with eight different types of thermocouple probes, the TC101A can measure
temperatures as low as -270 °C , and up to as high as 1820 °C (probe dependent), with an
environmental operating temperature range of -40 °C to +80 °C for the data logger body.
The 10 year battery life and the memory storage capacity of 500,000 readings with optional
memory wrap makes the TC101A ideal for extended deployments.
With the user friendly MadgeTech Data Logger Software, the TC101A is easily connected
to a PC to download the collected data. The MadgeTech Software is capable of presenting
the data in graphic, tabular, and summary formats for reporting. Data can also be exported
easily to Excel for further analysis and calculations.
MADGETECH DATA LOGGER SOFTWARE
A
Key
A Graph View
B Tabular Data View
C Statistics
D Digital Calibration
E Copy to Excel®
B
C
E
D
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
Software Features:
• Multiple graph overlay
• Statistics
• Digital calibration
• Zoom in/ zoom out
• Lethality equations (F0, PU)
• Mean Kinetic Temperature
• Full time zone support
• Data annotation
• Min./Max./Average lines
• Data table view
• Automatic report generation
• Summary view
• Multilingual
TC101A SPECIFICATIONS*
*SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC WARRANTY REMEDY LIMITATIONS
APPLY. CALL 1-603-456-2011 OR GO TO WWW.MADGETECH.COM FOR DETAILS.
Internal Channel
Temperature Range: -40 °C to +80 °C (-40 °F to +176 °F)
Temperature Resolution: 0.01 °C (0.018 °F)
Calibrated Accuracy: ±0.5 °C (±0.9 °F)
Remote Channel
• Female subminiature (SMP) (MP model)
Thermocouple Connection:
• Pluggable screw terminal (TB model)
• Fixed screw terminal (ST model)
Cold Junction Compensation: Automatic based on internal channel
Max. Thermocouple Resistance: 100 Ω
Thermocouple Type: Range (°C) Resolution Accuracy
J -210 to +760 0.1 °C ±0.5 °C
K -270 to +1370 0.1 °C ±0.5 °C
T -270 to +400 0.1 °C ±0.5 °C
E -270 to +980 0.1 °C ±0.5 °C
R -50 to +1760 0.5 °C ±2.0 °C
S -50 to +1760 0.5 °C ±2.0 °C
B +50 to +1820 0.5 °C ±2.0 °C
N -270 to +1300 0.1 °C ±0.5 °C
* Thermocouple accuracy is specified with a 24 AWG
Reading Rate:
1 reading every second up to 1 reading
every 24 hours
• 1,000,000 readings; software
Memory:
configurable memory wrap.
• 500,000 readings in multiple start/stop
mode or trigger settings mode
Wrap Around: Yes
• Immediate start
Start Modes:
• Delay start up to 18 months
• Multiple pushbutton start/stop
Stop Modes:
• Manual through software
• Timed (specific date and time)
Start and stop the device multiple times
Multiple Start/Stop Mode:
without having to download data or
communicate with a PC
To start the device:
Press and hold the pushbutton for 5 seconds,
the green LED will flash during this time. The
Multiple Start/Stop Mode
Activation:
device has started logging.
To stop the device:
Press and hold the pushbutton for 5 seconds,
the red LED will flash during this time. The
device has stopped logging.
Real Time Recording:
The device may be used with PC to
monitor and record data in real time.
Alarm: Programmable high and low limits; alarm is
activated when temperature reaches or exceeds sets
limits.
Alarm:
Alarm Delay: A cumulative alarm delay may be set
in which the device will activate the alarm (via LED)
only when the device has recorded a user specified
time duration of data.
High and Low limits may be set for the thermocouple
channel. Once data meets or exceed sets limits, the
Trigger Settings:
device will record to memory. Bi-level start and stop
triggers can also be programmed. Users can specify the
number of readings to take after the device triggers.
Green LED blinks: 10 second rate to indicate logging,
15 second rate to indicate delay start mode
LED Functionality:
Red LED blinks: 10 second rate to indicate low battery
and/or full memory, 1 second rate to indicate an alarm
condition
An optional password may be programmed into the
Password Protection:
device to restrict access to configuration options.
Data may be read out without the password.
Battery Type: 3.6V lithium battery included; user replaceable
10 years typical at a 15 minute reading rate
Battery Life:
Graph display of the device recording in a 25 °C environment.
Data Format: Date and time stamped °C, °F, K, °R; µV, mV, V
Time Accuracy: ±1 minute/month (at 20 ºC, stand alone data logging)
Computer Interface: USB (interface cable required); 115,200 baud
Software: XP SP3/Vista/Windows 7/Windows 8
Operating Environment:
-40 °C to +80 ºC (-40 °F to +176 °F),
0 %RH to 95 %RH non-condensing
Dimensions: 1.4 in x 2.2 in x 0.6 in (36 mm x 56 mm x 16 mm)
Weight: 0.9 oz (24 g)
Approvals: CE
BATTERY WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT,
CHARGE, FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 80 °C (176 °F).
ORDERING INFORMATION
MODEL DESCRIPTION
TC101A-MP Thermocouple Data Logger, standard mini plugs
TC101A-ST Thermocouple Data Logger, fixed screw terminals
TC101A-TB Thermocouple Data Logger, pluggable screw terminals
IFC200 Software, Manual and USB interface cable
Calibration Certificate Calibration Certificate available for data logger
LTC-7PN Replacement battery for TC101A
For Quantity Discounts call 603-456-2011 or email sales@madgetech.com
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
Temperature
ASK ABOUT
OUR OTHER
DATA
LOGGERS
DOC-1218009-00 REV 13 2014.12.11
Humidity
Pressure
pH
Level
Shock
LCD Display
Pulse/Event/State
Current
Voltage
Wireless
Intrinsically Safe
Spectral Vibration
Motion