STATE101A
STATE DATA LOGGER
Features
• 10 Year Battery Life
• 4 Hz Second Reading Rate
• Multiple Start/Stop Function
• Ultra High Speed Download
• 406,323 Reading Storage Capacity
• Memory Wrap
• Battery Life Indicator
• Optional Password Protection
• Field Upgradeable
Benefits
• Simple Setup and Installation
• Minimal Long-Term Maintenance
• Long-Term Field Deployment
Applications
• Heating and Cooling Systems
• Security Systems
• Power Supply On/Off
• Relay or Dry Contact Closure
• TTL High/Low
• Monitoring Gas, Water or Electric
Pumps
• Status or State Recording
• Replace Costly Strip Chart
Recorders
The State101A is one of MadgeTech’s newest data
loggers. It is part of a new series of low cost, state-ofthe-art data logging devices. MadgeTech has taken
the lead in offering the most advanced, low cost,
battery powered data loggers in the world today.
The State101A offers a 10 year battery life, 4 Hz
reading rate, a multiple start/stop function, ultrahigh speed download capability, 406,323 reading
storage capacity, optional memory wrap, battery life
indicator, optional password protection and more. The State101A is priced at $99 each and
can be delivered from stock now. Our research has shown that the State101A is second to
no other data logger when it comes to price and performance.
Using the MadgeTech Software, starting, stopping and downloading from the State101A
is simple and easy. Graphical, tabular and summary data is provided for analysis and data
can be viewed in multiple units, using the Engineering Units function. The data can also be
automatically exported to Excel® for further calculations.
As the leader in low power data logger technology, MadgeTech continuously improves
its products and develops solutions to meet ever-changing challenges. The State101A was
designed with our customers in mind. MadgeTech offers free firmware upgrades for the life
of the product so that data loggers already deployed in the field can grow with new
technological developments. Units do not need to be returned to the factory for upgrades.
The user can do this automatically from any PC.
MADGETECH DATA LOGGER SOFTWARE
A
Key
A Graph View
B Tabular Data View
C Statistics
D Digital Calibration
E Copy to Excel®
B
C
E
D
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
Software Features:
• Multiple graph overlay
• Statistics
• Digital calibration
• Zoom in/ zoom out
• Lethality equations (F0, PU)
• Mean Kinetic Temperature
• Full time zone support
• Data annotation
• Min./Max./Average lines
• Data table view
• Automatic report generation
• Summary view
• Multilingual
STATE101A SPECIFICATIONS*
Input Connection: Removable screw terminal
Input Range: 0 V to 30 V
Input Low: <0.4 V
Input High: >2.8 V
Internal Weak Pull-Up: <60 µA
Input Impedance: >60 KΩ
Time Resolution: 4 Hz (reading rate selectable in software)
Reading Rate: 4 Hz to 1 every 24 hours
Memory:
Wrap Around: Yes
Start Modes:
Stop Modes:
Multiple Start/Stop Mode:
Multiple Start/Stop Mode
Activation:
Real Time Recording:
LED Functionality:
406,323 readings; software configurable
memory wrap
• Immediate start
• Delay start up to 18 months
• Multiple pushbutton start/stop
• Manual through software
• Timed (specific date and time)
Start and stop the device multiple times
without having to download data or
communicate with a PC
To start the device:
Press and hold the pushbutton for 5
seconds, the green LED will flash during
this time. The device has started logging.
To stop the device:
Press and hold the pushbutton for 5
seconds, the red LED will flash for three
seconds and then the green LED will flash
for two seconds. The device has stopped
logging.
The device may be used with PC to
monitor and record data in real-time
Green LED blinks:
10 second rate to indicate logging
15 second rate to indicate delay start
mode
Red LED blinks:
10 second rate to indicate low battery
and/or full memory
An optional password may be programmed
Password Protection:
into the device to restrict access to
configuration options. Data may be read
out without the password.
Native measurement units can be scaled to
Engineering Units:
display measurement units of another type such
as on/off, open/closed and more.
Battery Type: 3.6V lithium battery included; user replaceable
10 years typical, dependent upon frequency and
duty cycle.
Battery Life:
Graph display of the device recording in a 25 °C environment.
Time Accuracy:
±1 minute/month
(at 20 ºC/68 ºF, stand alone data logging)
Computer Interface: USB (interface cable required); 115,200 baud
Software: XP SP3/Vista/Windows 7/Windows 8
Operating Environment:
Dimensions:
-40 ºC to +80 ºC (-40 ºF to +176 ºF),
0 %RH to 95 %RH non-condensing
1.4 in x 2.2 in x 0.6 in
(36 mm x 56 mm x 16 mm)
Weight: 0.9 oz (24 g)
Materials: ABS Plastic
Approvals: CE
BATTERY WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT,
CHARGE, FORCE OVER DISCHARGE, CRUSH, PENETRATE, OR INCINERATE. BATTERY MAY LEAK
OR EXPLODE IF HEATED ABOVE 80 ºC (176 ºF).
*SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.SPECIFIC WARRANTY AND
REMEDY LIMITATIONS APPLY. CALL 1-603-456-2011 OR GO TO WWW.MADGETECH.COM FOR
DETAILS.
ORDERING INFORMATION
MODEL DESCRIPTION PRICE (U.S.)
STATE101A State Data Logger $99.00
IFC200 Software, manual and USB interface cable $119.00
LTC-7PN Replacement battery for State101A $10.00
For Quantity Discounts call 603-456-2011 or email sales@madgetech.com
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
Temperature
ASK ABOUT
OUR OTHER
DATA
LOGGERS
DOC-1222009-00 REV 5 2014.07.31
Humidity
Pressure
pH
Level
Shock
LCD Display
Pulse/Event/State
Current
Voltage
Wireless
Intrinsically Safe
Spectral Vibration
Motion