RHTEMP2000
Features
Large, backlit LCD display
Front keypad w/lock feature
User-selectable measurement units
Simultaneous display of temperature
and humidity
N.I.S.T. traceable calibration
Min./max. & average statistics
Programmable start/stop time
Convenient status indicators
User replaceable battery and
external power
Wall mountable
Applications
Remote data logging
Warehouse monitoring
HVAC
Medical and Pharmaceutical
Museum monitoring
Environmental studies
Implement HACCP programs
Refrigeration
Mineral Processing
- Electrostatic Separation
HUMIDITY & TEMPERATURE DATA LOGGER W/LCD DISPLAY
he RHTemp2000 is perfect
T
for applications requiring
instant remote readings of
environmental parameters,
including temperature and
humidity.
The 8-button keypad and
large LCD provide convenient
access to current data and
recorder setup. Additionally,
memory and battery levels,
external power status, and
sampling and recording status are shown on the LCD.
Available on-screen data includes: statistics (min, max, average) for all two
channels; recording status (start, stop and recording rate); display options (channels
shown, units, text size); and calibration information (date calibrated, date for
recalibration). Statistics can be cleared at any time during logging.
With 131,071 readings per channel, the RHTemp2000 has one of the largest
memory capacities of any similar data recorder on the market. The non-volatile
memory will retain recorded data, even if AC and battery power are lost.
The RHTemp2000 runs on a 9V battery with a typical battery life of 1 year, at a 1
min reading rate with the display off. With continuous LCD and no backlight
usage, the average battery life is 30 days.
backlight have configurable auto-off options. Those wanting to keep the LCD display
and backlight continuously active need only to connect the unit to an AC power
supply, keeping the 9V battery connected as a back-up.
N.I.S.T. traceable calibration is available for users needing to meet regulatory
requirements. Creating permanent records, performing data calculations, and the
graphing of data is quick and easy: Simply connect the interface cable to an available
USB port and, with a few clicks of the mouse, data is downloaded and ready for review
or export to Excel
®.
For power savings, both the LCD and
MadgeTech Data Recorder Software
displays humidity and temperature data in an easy
to use graph.
®
The Windows
the user to effortlessly collect, display and
analyze data. A variety of powerful tools allow
you to examine, export, and print professional
looking data with just a click of the mouse.
Click MadgeTech Software for more information or to
879 Maple Street · Contoocook, NH 03229
PO Box 50 · Warner, NH 03278 · Phone: (603) 456-2011 · Fax: (603) 456-2012
-based software package allows
download the software.
RHTEMP2000 SPECIFICATIONS*
TEMPERATURE
Range:
Resolution:
Calibrated Accuracy:
HUMIDITY
Range:
Resolution:
Calibrated Accuracy:
Specified Accuracy Range:
DOT-MATRIX LCD
Dimensions:
Indicators:
Backlight:
BATTERY WARNING: MAY LEAK AND/OR FLAME IF OPENED, RECHARGED,
CONNECTED IMPROPERLY, OR DISPOSED OF IN FIRE.
-20 to +60ºC
0.1ºC
±0.5ºC (0 to +50ºC)
0 to 95%RH
0.1%RH
±3%RH (±2%RH typical at 25ºC)
+10 to +40°C, 10 to 80%RH
2.5” x 1.375” (63mm x 35mm)
Configurable channel text size
Text:
Power, status, memory
Configurable w/auto shut-off and
contrast adjustment
Start/Stop Time:
Memory:
Reading Rate:
Calibration:
Calibration Date:
Battery Type: 9V lithium battery included, user replaceable;
Battery Life:
Unit Display:
Time Accuracy:
Computer Interface:
Software:
Operating Environment:
Dimensions:
Weight:
Enclosure:
Approvals:
Software programmable start time and date, up to
six months in advance; programmable stop time
131,071 readings per channel; 262,143 total
readings; software configurable memory wrap
1 reading every 2 seconds to 1 every 24 hours
Digital calibration through software
Automatically recorded within device
optional AC adapter
1 year battery life at 1 min reading rate with
display off. 30 days typical with continuous LCD
and no backlight usage.
Date and time stamped ºC, ºF, K, ºR ; %RH, mg/
ml water vapor concentration, dew point
±1 minute/month (at 20º to 30°C)
USB (interface cable required); 115,200 baud
XP SP3/VIsta/Windows 7
-20 to +60ºC, 0 to 95%RH non-condensing
4.8” x 3.3” x 1.25” (122mm x 84mm x 32mm)
16 oz (440 g)
Black anodized aluminum
CE
SOFTWARE FEATURES
Multiple Graphs:
Real-Time
Recording:
Graphical Cursor:
Data Table:
Scaling Options:
Formatting Options:
ORDERING INFORMATION
Model
RHTEMP2000
IFC200
NIST
U9VL-J
For Quantity Discounts call 603-456-2011 or email sales@madgetech.com
Simultaneously analyze data from
several units or deployments; easily
switch to a single data series
Collect and display data in real-time
while continuing to log
One click displays readings by time,
value, parameter or sample number
Instantly access tabular view for
Logger Configuration:
detailed dates, times, values, and
annotations
Autoscale function fits data to the
Communications:
screen, or allows user to manually
enter their own values
Change colors, line styles, plotting
options, show or hide channels quickly
Description
Humidity and Temperature Recorder w/LCD
Display
Software, manual and USB interface cable $119.00
N.I.S.T. Calibration Certificate Call for Options and Pricing
Replacement battery for RHTemp2000 $15.00
Statistics:
Export Data:
Calibration:
Printing:
Price (U.S.)
$399.00
Calculate averages, min, max, standard
deviation, and mean kinetic temperature
with the touch of a button
Export data in a variety of common formats, or
switch to Excel
®
with a single click
Automatically calculate and store calibration
parameters
Easy set up and launch of data loggers with
immediate or delayed start, preferred sample
rate, and device ID
Automatically sets up communications port, or
lets user select configuration
Automatically print graphical or tabular data
*SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
SPECIFIC WARRANTY AND REMEDY LIMITATIONS APPLY.
CALL 1-603-456-2011 OR GO TO WWW.MADGETECH.COM FOR DETAILS.
ASK ABOUT OUR OTHER
DATA RECORDERS
Temperature
Humidity
Pressure
pH
Level
Shock
LCD Display
Pulse/Event/State
Low Level Current
Low Level Voltage
RF Transmitters
Intrinsically Safe
Spectral Vibration
PO Box 50 · Warner, NH 03278 · Phone: (603) 456-2011 · Fax: (603) 456-2012
879 Maple Street · Contoocook, NH 03229
DOC-1151009-00 REV K 2011.01.11