Description RHTemp1000IS
Temperature Sensor Resistance Temperature Detector (RTD)
Temperature Range -40 °C to +80 °C (-40 °F to +176 °F)
Temperature Resolution 0.01 °C
Calibrated Accuracy +0.5 °C (0 °C to 55 °C)
Humidity Sensor Capacitive Polymer
Humidity Range 0 %RH to 100 %RH (non-condensing)
Humidity Resolution 0.1 %RH
Calibrated Accuracy +3 %RH maximum
Specified Accuracy Range
Memory 16,384 readings per channel
Memory Wrap Yes
Reading Rate 1 reading every second up to 1 reading every 24 hours
Time Accuracy ±1 minute/month at 25 °C
Data Format Date and time stamped ºC, ºF, K, ºR; %RH, mg/mL, Dew Point
Required Interface Package IFC400 or IFC406
Baud Rate 125,000 baud
Typical Battery Life 2 years typical at 25 °C (15 minute reading rate)
Operating System
Compatibility
MadgeTech Software
Compatibility
Operating Environment
Material 316 Stainless Steel/Radel
Dimensions 1.7 in x 0.97 in x 0.97 in (42 mm x 24.6 mm x 24.6 mm)
Weight 2.3 oz (65 g)
Approvals
Non-incendive for Class I, Division 2, groups ABCD Hazardous
Hysteresis Error 1 % Typical, 3% Maximum
Standard Software version 4.1.0.2 or later
Secure Software version 4.1.3.0 or later
0 %RH to 100 %RH (non-condensing)
CE; Intrinsically Safe for Class I, Div 1, groups ABCD;
25 %RH to 75 %RH
+20 °C to +40 °C
Windows XP SP3 or later
-40 °C to +80 °C (-40 °F to +176 °F),
(Classified) Locations
Product User Guide
RHTemp1000IS
Battery Warning
WARNING: FIRE, EXPLOSION AND SEVERE BURN HAZARD. DO NOT RECHARGE, DISASSEMBLE,
HEAT ABOVE 100 °C (212 °F), INCINERATE, CRUSH, OR EXPOSE CONTENTS TO WATER. FAILURE TO
USE A TADIRAN TL-2150 BATTERY WILL VOID THE INTRINSICALLY SAFE/NON-INCENDIVE RATINGS.
Specifications subject to change. See MadgeTech’s terms and conditions at madgetech.com.
MadgeTech, Inc.
6 Warner Road
Phone (603) 456-2011
madgetech.com
l
Warner, NH 03278
l
Fax (603) 456-2012
l
info@madgetech.com
DOC-1272035-00 REV 5 2019.07.08
RHTemp1000IS
Intrinsically Safe Rugged Humidity and Temperature Data Logger
To view the full MadgeTech product line,
visit our website at madgetech.com.
RHTemp1000IS
Product Notes
Intrinsic Safety Approval
The RHTemp1000IS has been certified by FM Approvals as Intrinsically Safe (IS) for use in
Class I, Division 1, groups A, B, C, D, and Non-incendive (NI) for use in Class I, Division 2,
groups A, B, C, D Hazardous (Classified) Locations. The rating listed in the FM Approvals
guide is as follows:
RHTemp1000IS. Temperature and Humidity Recorder.
IS / I / 1 / ABCD T4A Ta=80 °C; NI / I / 2 / ABCD / T4A Ta=80 °C
These are the only safety ratings relevant to the use of this product. Use of this product
in hazardous environments not specifically covered by this rating, is prohibited, unless
the user takes the appropriate steps to ensure the safety of the product and assumes full
responsibility for its safe use.
O-Rings
O-Ring maintenace is a key factor when properly caring for the RHTemp1000IS. The
O-Rings ensure a tight seal and prevent liquid from entering the inside of the device.
Please refer to the application note “O-Rings 101: Protecting Your Data,” found on the
MadgeTech website for information on how to prevent O-Ring failure.
Communication
To ensure desired operation of the RHTemp1000IS, please keep the surface clear of any
foreign objects or substances. The RHTemp1000IS’s data is downloaded through external
contact with the IFC400 or IFC406 docking station. Covering the surface with foreign objects
(i.e. Calibration Labels) can prevent the communication and/or downloading process.
Installation Guide
Installing the Interface cable
- IFC400 or IFC406:
Refer to the “Quick Start Guide” included in the package.
Product User Guide
Device Operation
Connecting and Starting the data logger
- Once the software is installed and running, plug the interface cable into the docking
station.
- Connect the USB end of the interface cable into an open USB port on the computer.
- Place the data logger into the docking station.
- The data logger will automatically appear under Connected Devices within the software.
- For most applications, select Custom Start from the menu bar and choose the desired start
method, reading rate and other parameters appropriate for the data logging application
and click Start. (Quick Start applies the most recent custom start options, Batch Start is used
for managing multiple loggers at once, Real Time Start stores the dataset as it records while
connected to the logger.)
- The status of the device will change to Running, Waiting to Start or Waiting to Manual
Start, depending upon your start method.
- Disconnect the data logger from the docking station and place it in the environment to
measure. Note: The device will stop recording data when the end of memory is reached or the device is stopped, unless
user selectable memory wrap is enabled. At this point the device cannot be restarted until it has been re-armed by the
computer.
Downloading data from a data logger
- Connect the data logger via the IFC400 or IFC406 docking station.
- Highlight the data logger in the Connected Devices list. Click Stop on the menu bar.
- Once the data logger is stopped, with the logger highlighted, click Download. You will
be prompted to name your report.
- Downloading will ooad and save all the recorded data to the PC.
Device Maintenance
Battery Replacement
Materials:
TL-2150/S Battery (user replaceable)
- Unscrew the bottom of the logger and remove the battery.
- Place the new battery into the logger. Note the polarity of the battery.
- Screw the cover back onto the logger.
Installing the software
Software can be downloaded from the MadgeTech website at madgetech.com. Follow
the instructions provided in the Installation Wizard to install the MadgeTech Software.
Recalibration
The RHTemp1000IS standard calibration is one temperature point at 25 °C and two
humidity points at 25 %RH and 75 %RH.
Prices and specifications subject to change. See MadgeTech’s terms and conditions at madgetech.com.
To send the devices back, visit madgetech.com to initiate the RMA Process.