MadgeTech RFVolt2000A Specifications

RFVOLT2000A
WIRELESS VOLTAGE DATA LOGGER
Features
• Battery Life Indicator
• Digital Display
• Direct USB Interface
• AC Power connection via USB
• Configurable Alarms
• Ability to manually reset statistics
• 5 year battery life at 15 Minute
Reading Rate
• 160mV Model Measures Differential
Voltage
Benefits
• Digital Display Provides Instant Access
to Current Readings and Statistics
• Minimal Long-Term Maintenance
• Readings displayed in users selected
measurement unit
• Time and Money Saving with Battery
Life Management
• Continuous monitoring
• E-mail, text message and audible alerts
provides assurance and quality control
Applications
• Battery Usage Studies
• Solar Cell Monitoring
• Cathodic Protection Monitoring
• Applications that require an
external sensor:
- Pressure Monitoring
- CO2 Monitoring
• 160mV Model Measures Radio or
Electromagnetic Frequency Interference
The RFVolt2000A is a wireless data logger designed to measure and record DC voltage signals. The data logger can connect directly to DC voltage sources which makes it ideal for battery usage studies, solar energy monitoring and other DC voltage monitoring applications. The RFVolt2000A can also be interfaced with a wide range of voltage output sensors, including pressure sensors and CO2 sensors, as well as transmitters and other transducers. The RFVolt2000A is available in a 2.5V, 15V, 30V or 160mV measurement range.
The RFVolt2000A features an LCD screen which provides instant access to the current reading, minimum, maximum and average statistics. Through the software, the device can be programmed with engineering units, which convert the voltage signals into a different unit of measure such as PSI, % or PPM. The engineering unit is available for display on the LCD screen as well as in the software. The statistics can be reset through the keypad of the device, allowing customers to keep track of statistics over certain time periods. This feature does not erase the data recorded, but only resets the statistics count.
The RFVolt2000A can be used as a standalone data logger, or used with the RFC1000 wireless transceiver, to transmit data back to a central PC. The RFVolt2000A transmits up to 500 ft line of sight to the RFC1000 transceiver. Multiple RFC1000’s can be used as repeaters and transmit up to 1000 ft line of sight to other RFC1000’s. This allows the data to be sent over a greater distance.
The RFVolt2000A-160mV model is a wireless, differential voltage data logger. The device is equipped with a three position terminal block to allow for a positive, negative and ground connection. This allows the measurement of the voltage difference between two signals tied to the same ground.
The RFVolt2000A can be used as a single, wireless data logging system, or can be expanded to a large scale system, which can include hundreds of data loggers measuring different parameters such as temperature, humidity and more (additional MadgeTech wireless data loggers and transceivers may be required). The RFVolt2000A utilizes the latest MadgeTech 4 Software. Data can be viewed in graphical or tabular formats and summary and statistics views are available for further analysis. The software features export to Excel®, data annotation, digital calibration and more.
MADGETECH DATA LOGGER SOFTWARE
Key
Graph View
Tabular Data View
Statistics
Properties
Copy to Excel
Software Features:
Multiple graph overlay
Statistics
Digital calibration
Zoom in/ zoom out
Lethality equations (F0, PU)
Full time zone support
Data annotation
Min./Max./Average lines
Data table view
Automatic report generation
Summary view
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
RFVolt2000A SPECIFICATIONS*
*SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC WARRANTY REMEDY LIMITATIONS
APPLY. CALL 1-603-456-2011 OR GO TO WWW.MADGETECH.COM FOR DETAILS.
General
Reading Rate: 1 reading every second up to 1 reading every 24 hours
Memory: 32,256 readings
• Green LED blinks every 5 seconds to indicate unit is logging
LED Functionality:
Memory Wrap
Around:
Start Modes: Immediate Start & Delayed Start
Audible Alarm
Functionality:
Battery Type: Ultralife 9V Lithium included; user replaceable
Battery Life: Approximates 5 years typical for 15 minute reading rate
Time Accuracy: ± 1 minute/month
Computer Interface:
Software: XP SP3/Vista/Windows 7/Windows 8 (MadgeTech 4 only)
Operating
Environment:
Dimensions:
Weight 4.1 oz (0.2563 lbs)
Enclosure Material: ABS Plastic
Approvals:
• Blue LED blinks every 15 seconds to indicate unit is in wireless mode
• Red LED blinks every 1 second to indicate alarm condition
Yes
User configurable audible, on-screen, email and text (SMS) alarms.
Alarm:
Alarm Delay: A cumulative alarm delay may be set in which the device will activate the alarm (via LED) only when the device has recorded a user specified time duration of data.
1 Beep per second for reading alarm above/below threshold
USB to mini USB, 250,000 baud for standalone operation or RFC1000/RFC1000-CE/RFC1000-IP69K required for wireless operation
-20 °C to +60 °C (-4 °F to +140 °F)
0 %RH to 95 %RH non-condensing
3.5 in x 3.17 in x 0.95 in
(88.9 mm x 80.5 mm x 24.1 mm) - Data logger only
US (FCC), CA (IC), CE, South Korea (KCC), China (CMIIT), Japan (LCIE)
Measurement
2.5 V:-3 VDC to +3 VDC
Measurement Range:
Measurement Resolution:
Calibrated Accuracy:
Response Time: 150 mS at sensor
15 V:-8 VDC to +24 VDC 30 V:-8 VDC to +32 VDC 160 mV:-160 mVDC to +160 mVDC
2.5 VDC (0.1 mVDC) 15 VDC (0.5 mVDC) 30 VDC (1.0 mVDC) 160 mVDC (5 µV)
2.5 V: ±0.05%FSR at 25 °C (77 °F) 15 V: ±0.05%FSR at 25 °C (77 °F) 30 V: ±0.05%FSR at 25 °C (77 °F) 160 mV: ±0.01%FSR at 25 °C (77 °F)
Wireless
RF Frequency:
Transceiver Sensitivity
Transmission Distance
Transmission Distance
(to other RFC1000’s)
BATTERY WARNING: May leak, flame or explode if disassembled, shorted, charged, connected together,
mixed with used or other batteries, exposed to fire or high temperature. Discard used battery promptly. Keep out of reach of children.
(RFC1000):
(to data loggers)
2.45 GHz IEEE 802.15.4 ultra-low power wireless transceiver with fully bi-directional communication
ISM band 2.405-2.475 GHz Operation (channels 11
Band:
through 25) @ 250 kbps data rate
-95 dBm typical
• RFC1000, RFC1000-CE & RFC1000-IP69K
2,000 ft max. outdoors - line of sight unobstructed 500 ft max. indoors - typical urban environment
• RFC1000
4,000 ft max. outdoors - line of sight unobstructed 1,000 ft max. indoors - typical urban environment
• RFC1000-CE
2,500 ft max. outdoors - line of sight unobstructed 700 ft max. indoors - typical urban environment
• RFC1000-IP69K
4,000 ft max. outdoors - line of sight unobstructed 1,000 ft max. indoors - typical urban environment
ORDERING INFORMATION
MODEL DESCRIPTION
RFVolt2000A Wireless Voltage Data Logger (2.5 V, 15 V, 30 V, 160 mV)
RFC1000 Wireless RF transceiver/repeater. USB to mini USB adapter & power supply included
RFC1000-CE Wireless RF transceiver/repeater, CE approved for Europe. USB to mini USB adapter & power supply included
RFC1000-IP69K Wireless RF transceiver/repeater, splash proof with an IP69K rating. USB to mini USB adapter included
Calibration Certificate Calibration Certificate available for data logger
U9VL-J Replacement battery for RFVolt2000A
For Quantity Discounts call 603-456-2011 or email sales@madgetech.com
Countries approved for use, purchase and distribution of the RFVolt2000A:
Australia, Austria, Belgium, Bulgaria, Canada, Chile, China, Columbia, Croatia, Cyprus, Czech Republic, Denmark, Ecuador, Estonia, Finland, France, Germany, Greece, Honduras, Hungary, Iceland, Ireland, Israel, Japan, Latvia, Liechtenstein, Lithuania, Luxembourg, Malaysia, Malta, Mexico, New Zealand, Norway, Peru, Poland, Portugal, Romania, Saudi Arabia, Singapore, Slovakia, Slovenia, South Africa, South Korea, Spain, Sweden, Switzerland, Thailand, The Netherlands, Turkey, United Kingdom, United States, Venezuela, Vietnam
6 Warner Road · Warner, NH 03278 · Phone: (603) 456-2011 · Fax: (603) 456-2012
DOC 1269009-00 REV 6 2015.01.02