PR1000
PRODUCT USER GUIDE
Product Overview
The PR1000 is a pressure and temperature data logger
used to accurately monitor and record pressure and
temperature at user programmable reading intervals.
The rugged stainless steel design allows for the device
to be placed in harsh environments, which makes it well
suited for use with air conditioning systems, chilled water,
hot water, air, gas, oil and steam pressure systems. The
PR1000 also monitors and records transient pressure
through software configuration. Once the user defined
threshold is met, the PR1000 will record at up to 128Hz for
a user defined time period.
Water Resistance
The PR1000 is fully submersible and is rated IP68. It can be
placed in environments with up to 230 ft (70 m) of water.
Installation Guide
Installing the Software
The Software can be downloaded from the MadgeTech
Installing the Docking Station
IFC400 or IFC406 (sold separately) — Connect the device
into a USB port with the interface cable and install the
drivers.
• 902278-00 — PR1000-300-PSIG-KR
• 902270-00 — PR1000-30-PSIA-KR
• 902276-00 — PR1000-30-PSIG-KR
• 902275-00 — PR1000-5000-PSIA-KR
• 902273-00 — PR1000-500-PSIA-KR
• 902279-00 — PR1000-500-PSIG-KR
• 900319-00 — IFC400
• 900325-00 — IFC406
• 901745-00 — TL-2150/S Replacement Battery
Device Operation
Connecting and Starting the Data Logger
1. Once the software is installed and running, plug the
interface cable into the docking station.
2. Connect the USB end of the interface cable into an
open USB port on the computer.
3. Place the data logger into the docking station.
4. The data logger will automatically appear under
Connected Devices within the software.
5. For most applications, select Custom Start from
the menu bar and choose the desired start method,
reading rate and other parameters appropriate for the
data logging application and click Start. (Quick Start
applies the most recent custom start options, Batch
Start is used for managing multiple loggers at once,
Real Time Start stores the dataset as it records while
connected to the logger.)
Ordering Information
• 902244-00 — PR1000-1000-PSIA
• 902241-00 — PR1000-100-PSIA
• 902247-00 — PR1000-100-PSIG
• 902242-00 — PR1000-300-PSIA
• 902248-00 — PR1000-300-PSIG
• 902240-00 — PR1000-30-PSIA
• 902246-00 — PR1000-30-PSIG
• 902245-00 — PR1000-5000-PSIA
• 902243-00 — PR1000-500-PSIA
• 902249-00 — PR1000-500-PSIG
• 902274-00 — PR1000-1000-PSIA-KR
• 902271-00 — PR1000-100-PSIA-KR
• 902277-00 — PR1000-100-PSIG-KR
• 902272-00 — PR1000-300-PSIA-KR
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
6. The status of the device will change to Running or
Waiting to Start, depending upon your start method.
7. Disconnect the data logger from the interface cable
and place it in the environment to measure.
Note: The device will stop recording data when the end of memory
is reached or the device is stopped. At this point the device cannot be
restarted until it has been re-armed by the computer.
Product User Guide | 2

PR1000
PRODUCT USER GUIDE
Device Operation (cont’d)
Downloading Data from a Data Logger
1. Place the logger into the docking station.
2. Highlight the data logger in the Connected Devices
list. Click Stop on the menu bar.
3. Once the data logger is stopped, with the logger
highlighted, click Download.
4. Downloading will offload and save all the recorded
data to the PC.
Trigger Settings (Transient Mode)
The PR1000 samples up to 128 Hz (7.8 ms) and begins
recording after exceeding user defined setpoints. After
triggering, the device will record a chosen number of
samples (Window Mode) or until reaching the stop setpoint
(Two Point Mode). The device can take as many as 380,928
readings with both channels enabled and 419,020 pressure
only readings. The data logger will record up to 50 samples
of “pre-trigger” data.
1. In the Connected Devices panel, click the device
desired.
2. On the Device Tab, in the Information Group, click
Properties. Or, right-click the device and select
Properties in the context menu.
Device Maintenance
O-Rings
O-ring maintenance is a key factor when properly caring
for the PR1000. The O-rings ensure a tight seal and prevent
liquid from entering the inside of the device. Please refer
to the application note O-Rings 101: Protecting Your
Data, found at , for information on how
to prevent O-ring failure.
Battery Replacement
Materials: TL-2150/S Battery
1. Unscrew the bottom of the
logger and remove the battery.
2. Place the new battery into the
logger. Note the polarity of
the battery. It is important to
insert the battery with positive
polarity pointing upward
towards the pressure sensor.
Failure to do so could result
in product inoperability or
potential explosion if exposed
to high temperatures.
3. Screw the cover back onto the logger.
3. Select Trigger in the Properties window.
4. Trigger formats are available in Window or Two Point
Mode. Window
mode allows a high
and/or low trigger
set point, and a
trigger sample
count or “window”
of time recorded
when set points
are exceeded to
be defined. Two
point allows for different Start and Stop setpoints to be
defined for both the high and low triggers.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Product User Guide | 3