Part Number QuadVolt OctVolt
Voltage Rage
*See Table BelowVoltage Resolution
Voltage Accuracy
Memory 32,767/channel 16,383/channel
Sample Rate 1 second up to 12 hours
LED Indicator None
Channels 4 8
Required Interface Package IFC110 or IFC200
Baud Rate 2,400
Typical Battery Life 1 year
Operating Environment –40 to +60°C, 0 to 95%RH (non–condensing)
Material Anodized aluminum
Dimensions 3.5” x 4.4” x 1.0”
(89mm x 112mm x 26mm)
Approvals CE - 100mV only
*QuadVolt & OctVolt Range, Resolution and Calibrated Accuracy
Nominal Range +100mV 0 to 2.5V 0 to 15V 0 to 30V
Measurement Range (VDC)
Accuracy
Resolution (mV) 5µV 0.1 0.5 1.0
Common Mode Input Range 0 to 2.5V 0 to 2.5V 0 to 2.5V 0 to 2.5V
+150mV -0.25 to 2.75 -1 to 16 -2 to 32
+0.01%FSR +0.01%FSR +0.10%FSR +0.10%FSR
3.5” x 4.4” x 1.5”
(89mm x 112mm x 39mm)
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 60°C (140°F).
See MadgeTech’s terms and conditions at www.madgetech.com
Specifications subject to change.
Product Information Card
QuadVolt and OctVolt
QuadVolt-100mV
4-channel +100mV Low Level
DCVoltage Data Logger
QuadVolt-2.5V
4-channel 2.5V Low Level DC Voltage
Data Logger
QuadVolt-15V
4-channel 15V Low Level DC Voltage
Data Logger
QuadVolt-30V
4-channel 30V Low Level DC Voltage
Data Logger
OctVolt-100mV
8-channel +100mV Low Level DC
Voltage Data Logger
OctVolt-2.5V
8-channel 2.5V Low Level DC Voltage
Data Logger
OctVolt-15V
8-channel 15V Low Level DC Voltage
Data Logger
OctVolt-30V
8-channel 30V Low Level DC Voltage
Data Logger
MadgeTech, Inc.
PO Box 50
Phone 603.456.2011
www.madgetech.com
l
Warner, NH 03278
l Fax 603.456.2012
l
info@madgetech.com
DOC-1037035-00 REV 7 2012.02.16
To view the full MadgeTech product line,
visit our website at www.madgetech.com.

QuadVolt and OctVolt
Wiring the Data Logger
QuadVolt and OctVolt Single Ended Wiring (2.5, 15 and 30V)
Two-position removable screw terminal connections; accepts 2-wire configurations.
Connector for interface cable
+ Input
- Input
QuadVolt and OctVolt Differential Wiring (+100mV)
Three-position removable screw terminal connections; accepts 3-wire configurations.
Warning: Note the polarity instructions. Do not attach wires to the wrong terminals.
Product Notes
Engineering Units
Engineering units are used to convert one measurement reading to another. The
MadgeTech software allows for software level Engineering Units (conversion applied to
data after download). Certain devices have device level Engineering Units, which upon
download automatically appear in the chosen unit of measure.
Please refer to the application note “Engineering Units” and Technical Support Videos,
found on the MadgeTech website, for information on how to manage Engineering Units.
Also view the Engineering Units Video for step-by-step setup instructions.
Device Operation
Starting the data logger
- Click Device Menu then Start Device.
- Choose the desired start method.
- Choose the start parameters by selecting a Reading Rate suitable for your application.
- Enter in any other desired parameters and click Start.
- A box will appear stating the data logger has been started. Click OK.
- Disconnect the data logger from the interface cable and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the device
cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Connect the data logger to the interface cable.
- Click the Device Menu then Read Device Data. This will offload all recorded data onto
the PC.
Product Quick Reference Card
Installation Guide
Installing the Interface cable
- IFC200
Insert the device into a USB port. The drivers will install automatically.
- IFC110
Plug the serial cable into the port and verify it is secure.
Installing the software
Insert the Software CD in the CD-ROM Drive. If the autorun does not appear, locate the
drive on the computer and double click on Autorun.exe. Follow the instructions provided
in the Wizard.
Connecting the data logger
- Once the software is installed and running, plug the interface cable into the data logger.
- Click the Communication Menu, then Auto Configure Port.
- After a moment, a box will appear stating a device has been found.
- Click OK. The Device Status box will appear. Click OK.
- At this point, communications have been configured for your logger. These settings can
be found under the Communication Menu.
Note: For additional installation instructions refer to your “Data Logger & Software Operating Manual”.
Device Maintenance
Battery Replacement
Materials:
- Remove the cover from the device by unscrewing the four screws.
- Remove the battery from its compartment and unsnap it from the connector.
- Snap the new battery into the terminals and verify it is secure.
- Replace the cover taking care not to pinch the wires. Screw the enclosure back together
securely.
Note: Be sure not to over tighten the screws or strip the threads.
Recalibration
The QuadVolt or OctVolt standard calibration is dependant upon the range.
Calibration
Pricing: QuadVolt OctVolt
Recalibration traceable to NIST $69.00 $81.00
Recalibration $49.00 $61.00
Additional Services:
As Found Data $15.00 per parameter/channel
Verification Point $15.00 per point
Prices and specifications subject to change. See MadgeTech’s terms and conditions at www.madgetech.com
To send the devices back, visit www.madgetech.com, select Services then RMA Process.
3/32” HEX Driver (Allen Key) and Replacement Battery (U9VL-J)
Range 2.5V
Point
0mV and
90-100mV
15V
0mV and
2.25-2.5V
30V
0mV and
27-30V