MadgeTech LCS140 Specifications

LCS140
P
Lethality Compliance System
Need to record humidity at high temperatures? Look no further than the LCS140 Wet­Bulb/Dry-Bulb system. Ditch the complexity of calculating with a psychrometer, the LCS140 coupled with the MadgeTech 4 Software does all the work for you!
Capable of withstanding temperatures from -40 °C to +140 °C (-40 °F to +284 °F), the dual probe LCS140 takes wet-bulb and dry-bulb readings simultaneously to determine the amount of humidity present.
• LCS140 Dual Probe Data Logger
• Reservoir Bottle (recommended to use distilled water only)
• Wet Bulb Socks
• Hanging Fixture
The LCS140 is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.
MadgeTech 4 Software Features
Graph View
• Multiple graph overlay
• Statistics
• Digital calibration
• Zoom in/ zoom out
• Lethality equations (F0, PU)
• Mean Kinetic Temperature
• Full time zone support
• Data annotation
• Min./Max./Average lines
• Summary view
Cooling Flags
Export to Excel
Tabular Data View
Automation
Note: Only distilled water is recommended for use in the reservoir bottle.
Features
• 1 Second Reading Rate
• Programmable Start and Stop Time
• 32,767 Readings
• Memory Wrap
• User Replaceable Battery
• Battery Life Indicator
• Trigger Settings
• Optional Password Protection
LCS140
SPECIFICATIONS
Specifications are subject to change without notice. Specific warranty remedy limitations apply. Call (603) 456-2011 or go to madgetech.com for details.
TEMPERATURE
Temperature Sensor Rigid RTD Probe
Temperature Range -40 °C to +140 °C (-40 °F to +284 °F)
Resolution 0.01 °C (0.02 °F)
Calibrated Accuracy ±0.1 °C (±0.18 °F)
GENERAL
Start Modes
Stop Modes Manual or Timed (specific date and time)
Real Time Recording
Memory 32,767 readings
Password Protection
Readings in Trigger Settings Mode
Trigger Settings
Wrap Around Yes
Calibration Digital calibration through soware
Soware programmable immediate start or delay start up to 18 months in advance
May be used with PC to monitor and record data in real time
An optional password may be programmed into the device to restrict access to configuration options. Data may be read out with the password.
16,383 readings
High and Low limits may be set. Once data meets or exceed sets limits, the device will record to memory. Bi-level start and stop triggers can also be programmed. Users can specify the number of readings to take aer the device triggers. (Triggering
on channel #1 only)
Calibration Date Automatically recorded within device
Battery Type
Battery Life
Data Format Date and time stamped °C, °F, °R, K
IP Rating
LCS140 Data Logger
Time Accuracy
Computer Interface
Operating System Compatibility
Soware Compatibility
Operating Environment
Dimensions
Weight 7.8 oz (221 g)
Material 316 Stainless Steel / Radel
Approvals CE
BATTERY WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT
SHORT CIRCUIT, CHARGE, FORCE OVER DISCHARGE, CRUSH, PENETRATE, OR INCINERATE. BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 150ºC (302ºF).
3.6V high-temperature lithium battery included; user replaceable
1 year typical (1 minute reading rate at 25 °C/77 °F)
IP68
1 minute/month at 25 °C (77 °F) Extended Operation: ±20 minutes/month at 140 °C (±450 ppm)
IFC400 or IFC406 USB docking station required; 125,000 baud
Windows XP SP3 or later
Standard Soware version 4.2.19.0 or later Secure Soware version 4.2.18.0 or later
-40 °C to +140 °C (-40 °F to +284 °F) 0 %RH to 100 %RH, 0.002 PSIA to 60 PSIA
14 in x 1.75 in x 1.2 in (356 mm x 44 mm x 30 mm)
Ordering Information
LCS140 PN 902168-00 Lethality Compliance System
IFC400 PN 900319-00 Docking station with USB cable
LCS140 Data Logger PN 902229-00 LCS140 Data Logger only
LCS140 Hanging Fixture PN 902230-00 LCS140 Hanging Fixture only
LCS140 Glass Bottle PN 902231-00 LCS140 Glass Bottle 2 oz
LCS140 Extra Socks PN 902232-00 LCS140 Extra Socks (6 Pack)
ER14250MR-145 PN 900097-00 Replacement battery for LCS140 Dual Probe Data Logger
For Quantity Discounts call (603) 456-2011 or email sales@madgetech.com
6 Warner Road, Warner, NH 03278 (603) 456-2011 | madgetech.com DOC-1370009-00 REV 2 2020.04.02