MadgeTech HiTemp140X2 Data sheet

HITEMP140X2-TD
HIGH TEMPERATURE DUAL PROBE DATA LOGGERS WITH AMBIENT & REMOTE TEMPERATURE PROBES
Features
• ±0.1 °C (±0.18 °F) Accuracy
• Rigid Probe Measures from
-200 °C to +260 °C (-328 °F to +500 °F)
• Bendable Probe Measures from
-200 °C to +350 °C (-328 °F to +662 °F)
• Flexible Probe Measures from
-60 °C to +260 °C (-76 °F to +500 °F)
• Submersible (IP68)
• NIST Traceable
• User Replaceable Battery
• Trigger Settings
• Programmable Start and Stop Time
• Battery Life Indicator
Benefits
• Simple Setup and Installation
• Minimal Long-Term Maintenance
• Long-Term Field Deployment
Applications
• Autoclave Verification
• Implement HACCP Programs
• Food Preparation & Processing
• Environmental Studies
• Well Monitoring
• Washer Disinfectors
• Pasteurization
HiTemp140X2-TD-PT-1 HiTemp140X2-TD-PT-5 HiTemp140X2-TD-FP
The HiTemp140X2-TD series of dual probe data loggers offer extreme flexibility for high temperature monitoring applications. These models all feature a 2 inch rigid transitional diameter probe to measure ambient temperature, combined with a second bendable or flexible probe option.
The rigid 2 inch TD probe is made of stainless steel, offers a fast response time and is suitable for the harshest environments.
The HiTemp140X2-TD-PT-1 and the HiTemp140X2-TD-PT-5 models combine the 2 inch TD probe with a 24 inch bendable probe made of stainless steel with either a 1 inch or 5 inch probe sheath at the tip. The stainless steel PT probe options provide the ability to retain shape when bent into position and offer an extremely high measurement range of up to 350 °C.
The HiTemp140X2-TD-FP combines the 2 inch TD probe with a 72 inch RTD lightweight flexible FP probe, designed for easy placement. The flexible FP probe option is very pliable and coated with PFA insulation making it ideal for use inside small vials and test tubes. This probe style has a narrow diameter, high accuracy and is ideal for steam sterilization and lyophilization. The FP probe is also compatible with the MicroDisc probe attachment, used for the surface temperature monitoring of shelving and more.
The temperature operating range for the data logger body is -40 °C to 140 °C. Because of the simultaneous ambient and remote temperature recording, the HiTemp140X2-TD series is ideal for use in autoclave mapping, food processing applications, and much more.
The HiTemp140X2-TD series is compatible with the latest version of the MadgeTech Software. This allows for simple starting, stopping and downloading of collected data. The devices are able to store up to 32,700 time and date stamped readings in non-volatile solid state memory. Once the readings have been downloaded to the software, it can be viewed in graphic, tabular, and summary form for easy analysis, as well as the potential to be exported into Excel for further calculations.
MADGETECH DATA LOGGER SOFTWARE
Key
A Graph View
B Tabular Data View
C Statistics
D Digital Calibration
E Copy to Excel®
B
C
D
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
EA
Software Features:
• Multiple graph overlay
• Statistics
• Digital calibration
• Zoom in/ zoom out
• Lethality equations (F0, PU)
• Mean Kinetic Temperature
• Full time zone support
• Data annotation
• Min./Max./Average lines
• Data table view
• Automatic report generation
• Summary view
• Multilingual
HITEMP140X2-TD SPECIFICATIONS*
Temperature
• Hi Te mp140X 2- TD -PT :
Temperature Sensor:
Probe Measurement
Calibrated Accuracy: ±0.1 °C (±0.18 °F)
Range:
Temperature
Resolution:
General
Reading Rate: 1 reading every second up to 1 reading every 24 hours
Memory: 32,767 readings
Start Modes:
Stop Modes: Manual or Timed (specific date and time)
Real Time Recording: May be used with PC to monitor and record data in real time
Password Protection:
Readings in Trigger
Settings Mode:
Trigger Settings:
Wrap Around: Yes
Battery Type:
Battery Life:
Rigid RTD Probe with a Bendable RTD Probe
• Hi Te mp140X 2- TD -FP :
Rigid RTD Probe with a Flexible RTD Probe
• Rigid Probe: -200 °C to +260 °C (-328 °F to +50 0 °F)
• Bendable Probe: -200 °C to +350 °C (-328 °F to + 662 °F)
• Flexible Probe: -60 °C to +260 °C (-76 °F to +500 °F)
0.01 °C (0.02 °F)
• Software programmable immediate start
• Delay start up to 18 months in advance
An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password.
16,383 readings
High and Low limits may be set. Once data meets or exceed sets limits, the device will record to memory. Bi-level start and stop triggers can also be programmed. Users can specify the number of readings to take after the device triggers. (Triggering on
channel #1 only)
3.6V high-temperature lithium battery included;
user replaceable
1 year typical (1 minute reading rate at 25 °C/77 °F)
*SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC WARRANTY REMEDY LIMITATIONS
APPLY. CALL 1-603-456-2011 OR GO TO WWW.MADGETECH.COM FOR DETAILS.
Calibration: Digital calibration through software
Calibration Date: Automatically recorded within device
Data Format: Date and time stamped °C, °F, °R, K,
Time Accuracy:
Computer Interface: IFC400 or IFC406 USB docking station required; 125,000 baud
Operating System
Compatibility:
MadgeTech Software
Compatibility:
Operating
Environment:
IP Rating: IP68
Dimensions (body):
Dimensions (probe):
Weight:
Materials:
Approvals: CE
BATTERY WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT,
CHARGE, FORCE OVER DISCHARGE, CRUSH, PENETRATE, OR INCINERATE. BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 150 ºC (302 ºF).
• 1 minute/month at 25 °C (77 °F)
• Extended Operation: ±20 minutes/month at 140 °C (±450 ppm)
XP SP3/Vista/Windows 7/Windows 8
• MadgeTech Standard Software version 4.2.1.0 or later
• MadgeTech Secure Software version 4.2.0.0 or later
-40 °C to +140 °C (-40 °F to +284 °F) 0 %RH to 100 %RH, 0.002 PSIA to 100 PSIA
1.89 in x 0.97 in x 0.97 in (48 mm x 24.6 mm x 24.6 mm)
• HiTemp140X2-TD-PT Rigid Probe:
2.0 in x 0.125 in dia. (0.188 in transitional dia.) 51 mm x 3.2 mm dia. (4.8 mm transitional dia.)
• HiTemp140X2-TD-PT 1 Inch Bendable Probe: Probe tip: 1.7 in x 0.125 in dia. (42 mm x 3.2 mm dia.) Bendable portion: 22 in x 0.062 in dia. (559 mm x 1.6 mm dia.)
• HiTemp140X2-TD-PT 5 Inch Bendable Probe: Probe tip: 4.8 in x 0.125 in dia. with 1 in x 0.188 in dia. handle
(121 mm x 3.2 mm dia. with 25 mm x 4.8 mm dia. handle)
Bendable portion: 22 in x 0.062 in dia. (559 mm x 1.6 mm dia.)
• HiTemp140X2-TD-FP Flexible Probe:
72 in x 0.10 in (1829 mm x 2.5 mm)
• HiTemp140X2-TD-PT: 3.0 oz (85 g)
• HiTemp140X2-TD-FP: 3.5 oz (100 g)
• Body: 316 Stainless Steel, PEEK
• Rigid/Bendable Probe: 316 Stainless Steel
• Flexible Probe: PFA Insulated Cable
ORDERING INFORMATION
MODEL DESCRIPTION PRICE (U.S.)
HiTemp140X2-TD-FP
HiTemp140X2-TD-PT-1
HiTemp140X2-TD-PT-5
IFC400 Docking station with USB cable, software and manual. $120.00
IFC406 6 Port, Multiplexer docking station with USB cable, software and manual. $549.00
ER1425S-HT Replacement battery for the HiTemp140X2-TD Series $50.00
For Quantity Discounts call 603-456-2011 or email sales@madgetech.com
*To order the product with the NIST certificate add -CERT to the end of the part number and add $90.00 to the price.
High temperature dual probe data logger with one rigid transitional diameter probe and one flexible RTD probe.
High temperature dual probe data logger with one rigid probe with a transitional diameter probe and one 24 inch bendable probe with a 1 inch probe sheath.
High temperature dual probe data logger with one rigid probe with a transitional diameter probe and one 24 inch bendable probe with a 5 inch probe sheath.
$899.00
$899.00
$899.00
*NIST NIST Calibration Certificate. $90.00
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
Temperature
ASK ABOUT OUR OTHER
DATA
LOGGERS
DOC1297009-00 REV 2 2015.02.23
Humidity
Pressure
pH
Level
Shock
LCD Display
Pulse/Event/State
Current Voltage
Wireless
Intrinsically Safe
Spectral Vibration