MadgeTech HITEMP140-TSK Data Sheet

HITEMP140-TSK
HITEMP140 DATA LOGGER WITH THERMAL SHIELD
Features
• Withstands Temperatures between
–200 ºC up to +250 ºC
• Small Diameter: 2.0 in (51 mm)
• Submersible
• Immediate or Delay Start
• Up to 1 Second Reading Rate
Benefits
• Validate a Wide Range of Temperature
Processes Using One Data Logger
• HiTemp140 can be used With or
Without Thermal Shield
• Durable Thermal Shield Protects
Probe and Allows for a Fast
Response Time
Applications
• Peanut Roasting
• Food Processing
• Meat Processing
• Autoclave Validation
• Conveyer Ovens
• Dishwasher Testing
• Incubator Validation
The HiTemp140-TSK is a kit that includes a HiTemp140 data logger with either a 5.25 inch probe or a 7 inch probe style, housed in a thermal shield. The combined features of the +0.1 % accuracy of the HiTemp140 and the properties of the durable thermal shield allow the device to be used for a wide range of validation applications. This rugged system can be placed in and withstand temperature from -200 ºC to +250 ºC, making it ideal for use in autoclave validation, monitoring food processing and dishwasher testing.
Using the MadgeTech 4 software, the data logger is fast and easy to setup. Remove the thermal shield and place the HiTemp140 into the IFC400 or IFC406 docking station (sold separately). Using the software, an immediate or delay start can be chosen, as well as the reading rate. Select Start to program the settings and start the data logger. Place the thermal shield around the HiTemp140 and screw it back together. The device is ready to be deployed.
The HiTemp140-TSK can be completely submerged and is built for applications that require extreme temperature monitoring.
The HiTemp140-TSK flush style is designed to have the probe entirely exposed while the data logger is protected by the thermal sheild. This allows full use of the length of the probe for applications that require internal temperature monitoring. The Vented style offers more probe protection and is designed for shorter probe lengths in applications where the data logger might be subject to movement in a fully submerged application.
MADGETECH DATA LOGGER SOFTWARE
A
Key
A Graph View
B Tabular Data View
C Statistics
D Digital Calibration
E Copy to Excel®
B
C
D
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
Software Features:
E
Multiple graph overlay
Statistics
Digital calibration
Zoom in/ zoom out
Mean Kinetic Temperature
Full time zone support
Data annotation
Min./Max./Average lines
Data table view
Automatic report generation
Summary view
Multilingual
HITEMP140 SPECIFICATIONS*
*SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC WARRANTY REMEDY LIMITATIONS
APPLY. CALL 1-603-456-2011 OR GO TO WWW.MADGETECH.COM FOR DETAILS.
Temperature Sensor: 100 Ω Platinum RTD
Probe Measurement Range: -200 °C to +260 °C (-328 °F to +500 °F)
Temperature Resolution: 0.01 °C (0.02 °F)
• ±0.1 °C/±0.18 °F (20 °C to +140 °C/68 °F to +284 °F)
Calibrated Accuracy:
Start Modes:
Stop Modes: Manual or Timed (specific date and time)
Real Time Recording:
Password Protection:
Memory: 32,700 readings
Wrap Around: Yes
Reading Rate:
• ±0.3 °C/±0.54 °F (-20 °C to +19.99 °C/-4 °F to +67.98 °F)
• ±0.4 °C/±0.72 °F (-40 °C to -20.01 °C/-40 °F to -4.02 °F)
• Software programmable immediate start
• Delay start up to 18 months in advance
May be used with PC to monitor and record data in real time
An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password.
1 reading every second up to 1 reading every 24 hours
HITEMP140-TSK SPECIFICATIONS**
Operating
Environment:
Dimensions:
Material: Enclosure: PTFE
Weight:
-200 ºC to +250 ºC (-328 ºF to +482 ºF) (Time limited) 0 %RH to 100 %RH
• Flush Top: 2.75 in x 2.0 in dia. (69.85 mm x 51 mm dia.)
• Vented Top: 4.3 in x 2.0 in dia. (109.2 mm x 50.8 mm dia.)
• Flush: 6.7 oz (190 g) (not including data logger)
• Vented: 9.5 oz (270 g) (not including data logger)
Disclaimer and Terms of Use
Listed specifications can be used to determine maximum allowable exposure times for the HiTemp140 with Thermal Shield at different temperatures beyond the normal operating range of the logger. Both the data logger and Thermal Shield must be at ambient temperature (approximately 25 °C) before being placed in the extreme temperature environment. Immediately following exposure to high temperature, the data logger should be removed from the thermal shield (using appropriate precautions, as it could be VERY hot) OR the data logger and shield should be placed in a water bath (approximately 25 °C) for at least 15 minutes to allow it to cool. Failing to do this may allow heat trapped in the Thermal Shield to continue to heat the datalogger to potentially unsafe levels. If your application involves a ramp up to a temperature above 140 °C and/or any complex temperature profile that isn’t simply a constant temperature, please contact MadgeTech to determine whether the HiTemp140 with Thermal Shield is suitable. Please provide MadgeTech with a detailed description of your temperature profile, including temperatures, durations, ramp times, and process media (air, steam, oil, water, etc.) If MadgeTech is unable to definitively calculate the suitability of our product for your application, we can provide a test unit outfitted with a high temperature indicator sticker. This sticker has an indicator dot which will turn black if exposed to temperatures above 143 °C. Apply the sticker to the bottom of the data logger itself (not the thermal shield), remove the battery for safety, place the data logger into the thermal shield and run the assembly through the proposed temperature program. The first indicator dot on the sticker will turn black at 143 °C. If that happens, the HiTemp140 with thermal shield is not appropriate for the application and we will work to find a solution that is.
BATTERY WARNING: WARNING: FIRE, EXPLOSION,
AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE, FORCE OVER DISCHARGE, CRUSH, PENETRATE, OR INCINERATE. BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 150 ºC (302 ºF).
**Other probe lengths up to 7” available. Contact MadgeTech for details.
Maximum Exposure
Time Chart
Ambient Temperature
-200 °C (-328 °F) 12 minutes N/A 14 minutes N/A
-180 °C (-292 °F) 13 minutes N/A 15 minutes N/A
-160 °C (-256 °F) 15 minutes N/A 16 minutes N/A
-140 °C (-220 °F) 17 minutes N/A 18 minutes N/A
-120 °C (-184 °F) 19 minutes N/A 21 minutes N/A
-100 °C (-148 °F) 22 minutes N/A 24 minutes N/A
-80 °C (-112 °F) 27 minutes N/A 30 minutes N/A
-60 °C (-76 °F) 37 minutes 22 minutes 42 minutes 25 minutes
-40 °C to +140 °C
(-40 °F to +284 °F)
150 °C (302 °F) 59 minutes 34 minutes 66 minutes 40 minutes
160 °C (320 °F) 51 minutes 29 minutes 57 minutes 34 minutes
170 °C (338 °F) 43 minutes 25 minutes 48 minutes 29 minutes
180 °C (356 °F) 37 minutes 23 minutes 42 minutes 26 minutes
190 °C (374 °F) 34 minutes 20 minutes 38 minutes 23 minutes
200 °C (392 °F) 31 minutes 18 minutes 34 minutes 21 minutes
210 °C (410 °F) 29 minutes 17 minutes 32 minutes 19 minutes
220 °C (428 °F) 27 minutes 16 minutes 30 minutes 18 minutes
230 °C (446 °F) 25 minutes 15 minutes 27 minutes 17 minutes
240 °C (464 °F) 23 minutes 14 minutes 26 minutes 16 minutes
250 °C (482 °F) 22 minutes 13 minutes 24 minutes 15 minutes
ORDERING INFORMATION
MODEL DESCRIPTION PRICE (U.S.) Enclosure
HITEMP140-5-TSK HiTemp140-5.25 inch data logger and thermal shield $549.00 Flush or Vented
HITEMP140-7-TSK HiTemp140-7 inch data logger and thermal shield $549.00 Flush or Vented
ER1425S-HT Replacement battery for the HiTemp140 $50.00
For Quantity Discounts call 603-456-2011 or email sales@madgetech.com
*To order the product with the NIST certificate add -CERT to the end of the part number and add $60.00 to the price.
Battery Type:
Battery Life: 1 year typical (1 minute reading rate at 25 °C/77 °F)
Calibration: Digital calibration through software
Calibration Date: Automatically recorded within device
Data Format: Date and time stamped °C, °F, K, °R
Time Accuracy:
Computer Interface: IFC400 or IFC406 USB docking station required; 125,000 baud
Software: XP SP3/Vista/Windows 7/Windows 8 (MadgeTech 4 Only)
Operating Environment: -40 °C to +140 °C (-40 °F to +284 °F), 0 %RH to 100 %RH
Dimensions (Body): 1.9 in x 0.97 in dia. (48 mm x 24.6 mm dia.)
Model Number:
HITEMP40-5.25
HITEMP140-5.25-TD
HITEMP140-7
Weight: 4.2 oz (120 g)
Material: 316 Stainless Steel
Approvals: CE
3.6V high-temperature lithium battery included;
user replaceable
±1 minute/month at 20 °C to 30 °C (68 °F to 86 °F) (Stand alone mode)
Dimensions (Probe)
5.25 in x 0.188 in dia. (133 mm x 4.8 mm dia.)
5.25 in x 0.125 in dia. (0.188 in transitional dia.) 133 mm x 3.2 mm dia. (4.8 mm transitional dia.)
7.0 in x 0.188 in dia. (178 mm x 4.8 mm dia.)
HiTemp140-TS (Flush) HiTemp140-TS (Vented)
Exposure Time in Air
(150 °C/302 °F)
Indefinitely Indefinitely Indefinitely Indefinitely
IFC400 Docking station with USB cable, software and manual $120.00
IFC406
6 Port, Multiplexer docking station with USB cable, software and manual
*NIST NIST Calibration Certificate $60.00
Exposure Time in Liquid
(150 °C/302 °F)
Exposure Time in Air
(150 °C/302 °F)
$549.00
Exposure Time in Liquid
(150 °C/302 °F)
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
DOC-1238009-00 REV 14 2015.05.13