MadgeTech HiTemp140-TS Specifications

HITEMP140-TS
THERMAL SHIELD FOR THE HITEMP140 DATA LOGGER
Features
• Withstands Temperatures between
-200 ºC up to 250 ºC
• Small Diameter: 2.0 in (51 mm)
The HiTemp140-TS is a thermal shield designed for use with the HiTemp140 data logger. This durable enclosure allows the data logger to be used in temperatures from -200 °C to +250 °C, making it ideal for peanut roasting, food processing, autoclave validation and other extreme temperature applications.
• Submersible
To use, simply place the HiTemp140 in the IFC400 or IFC406
Applications
• Peanut Roasting
• Food Processing
docking station (sold separately). Use the MadgeTech software to program a start method and reading rate. Place the HiTemp140 in the HiTemp140-TS enclosure and screw it back together. The device is ready to be deployed.
• Autoclave Validation
• Conveyer Ovens
• Dishwasher Testing
HITEMP140-TS SPECIFICATIONS*
Operating
Environment:
Dimensions:
Material: Enclosure: PTFE
Weight:
Disclaimer and Terms of Use
Listed specifications can be used to determine maximum allowable exposure times for the HiTemp140 with Thermal Shield at dierent temperatures beyond the normal operating range of the logger. Both the data logger and Thermal Shield must be at ambient temperature (approximately 25 °C) before being placed in the extreme temperature environment. Immediately following exposure to high temperature, the data logger should be removed from the thermal shield (using appropriate precautions, as it could be VERY hot) OR the data logger and shield should be placed in a water bath (approximately 25 °C) for at least 15 minutes to allow it to cool. Failing to do this may allow heat trapped in the Thermal Shield to continue to heat the data logger to potentially unsafe levels. If your application involves a ramp up to a temperature above 140 °C and/or any complex temperature profile that isn't simply a constant temperature, please contact MadgeTech to determine whether the HiTemp140 with Thermal Shield is suitable. Please provide MadgeTech with a detailed description of your temperature profile, including temperatures, durations, ramp times, and process media (air, steam, oil, water, etc.) If MadgeTech is unable to definitively calculate the suitability of our product for your application, we can provide a test unit outfitted with a high temperature indicator sticker. This sticker has an indicator dot which will turn black if exposed to temperatures above 143 °C. Apply the sticker to the bottom of the data logger itself (not the thermal shield), remove the battery for safety, place the data logger into the thermal shield and run the assembly through the proposed temperature program. The first indicator dot on the sticker will turn black at 143 °C. If that happens, the HiTemp140 with thermal shield is not appropriate for the application and we will work to find a solution that is.
-200 ºC to +250 ºC (-328 ºF to +482 ºF) (Time limited) 0 %RH to 100 %RH, 0.002 PSIA to 100 PSIA
• Flush Top: 2.75 in x 2.0 in dia. (69.85 mm x 51 mm dia.)
• Vented Top: 4.3 in x 2.0 in dia. (109.2 mm x 50.8 mm dia.)
• Flush: 6.7 oz (190 g) (not including data logger)
• Vented: 9.5 oz (270 g) (not including data logger)
Ambient Temperature
-200 °C (-328 °F) 12 minutes N/A 14 minutes N/A
-180 °C (-292 °F) 13 minutes N/A 15 minutes N/A
-160 °C (-256 °F) 15 minutes N/A 16 minutes N/A
-140 °C (-220 °F) 17 minutes N/A 18 minutes N/A
-120 °C (-184 °F) 19 minutes N/A 21 minutes N/A
-100 °C (-148 °F) 22 minutes N/A 24 minutes N/A
-80 °C (-112 °F) 27 minutes N/A 30 minutes N/A
-60 °C (-76 °F) 37 minutes 22 minutes 42 minutes 25 minutes
-40 °C to +140 °C
(-40 °F to +284 °F)
150 °C (302 °F) 59 minutes 34 minutes 66 minutes 40 minutes 160 °C (320 °F) 51 minutes 29 minutes 57 minutes 34 minutes 170 °C (338 °F) 43 minutes 25 minutes 48 minutes 29 minutes 180 °C (356 °F) 37 minutes 23 minutes 42 minutes 26 minutes 190 °C (374 °F) 34 minutes 20 minutes 38 minutes 23 minutes 200 °C (392 °F) 31 minutes 18 minutes 34 minutes 21 minutes 210 °C (410 °F) 29 minutes 17 minutes 32 minutes 19 minutes 220 °C (428 °F) 27 minutes 16 minutes 30 minutes 18 minutes 230 °C (446 °F) 25 minutes 15 minutes 27 minutes 17 minutes 240 °C (464 °F) 23 minutes 14 minutes 26 minutes 16 minutes 250 °C (482 °F) 22 minutes 13 minutes 24 minutes 15 minutes
ORDERING INFORMATION
MODEL DESCRIPTION
HiTemp140-5.25/7 in Extended Range High Temperature Data Logger
HiTemp140-PT/FP Bendable Probe/Flexible Probe High Temperature Data Logger
For Quantity Discounts call (603) 456-2011 or email sales@madgetech.com
Flush Vented
*Specications are subject to change without notice. Specic warranty remedy limitations apply. Call (603) 456-2011 or go to madgetech.com for details.
HiTemp140-TS (Flush) HiTemp140-TS (Vented)
Exposure Time in Air Exposure Time in Liquid Exposure Time in Air Exposure Time in Liquid
Indefinitely Indefinitely Indefinitely Indefinitely
HiTemp140-TS Thermal Shield for the HiTemp140-5.25/7, HiTemp140-PT and HiTemp140-FP Data Logger
IFC400 Docking station with USB cable, software and manual
IFC406 6 Port, Multiplexer docking station with USB cable, software and manual
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
DOC-1238009-00 REV 13 2019.08.20