MadgeTech HiTemp140-M12 Operating Manual

Product User Guide
HiTemp140-M12
HiTemp140-M12
High Temperature Data Logger with an M12 Probe Connector
To view the full MadgeTech product line,
visit our website at www.madgetech.com.
Product User Guide
Table of Contents
HiTemp140-M12 Data Logger
To view the full MadgeTech product line, visit our website at www.madgetech.com.
HiTemp140-M12
Product Overview
The HiTemp140-M12 is a rugged and versatile high temperature data logger featuring an M12 probe connector. Compatible with a wide variety of M12 RTD probe styles, this data logger is capable of measuring up to 850 °C (1562 °F) (probe dependent).
All of MadgeTech’s HiTemp140 data loggers have a water tight body enclosure made of food grade stainless steel and can be placed in environments with temperatures as high as 140 °C (284 °F). The operating range of the data logger body can be extended to higher temperatures when used with MadgeTech’s thermal barrier options and a suitable probe.
The HiTemp140-M12 records and stores up to 43,690 time stamped readings and is equipped with non-volatile solid state memory which retains data even if the battery becomes discharged.
A wide selection of compatible M12 probes are available on the market to choose from, making the HiTemp140-M12 the most dynamic data logger of its kind. With the ability to change probes as needed, this device satisfies a multitude of application needs with one powerful data logger versus the need for multiple loggers.
Note: Specific M12 wiring configuration is required for compatibility. (see page 4)
Submergibility
The HiTemp140-M12 logger itself is rated IP40 and not submersible. It will inherit the IP rating of the probe it is attached to, allowing for potential submergibility, depending upon the probe.
O-Rings
O-ring maintenance is a key factor when properly caring for the HiTemp140-M12. The O-rings ensure a tight seal and prevent liquid from entering the inside of the device. Please refer to the application note “O-Rings 101: Protecting Your Data”, found on the MadgeTech website, for information on how to prevent O-ring failure.
Trigger Settings
The device can be programmed to only record based off user configured trigger settings.
1. In the Connected devices panel, select the intended device to change the settings.
2. On the Device tab, in the Information group, click Properties. Users can also right-click on the device and select Properties in the context menu.
3. Click Trigger and configure the Trigger settings. Trigger formats are available in Window and Two Point (bi-level) mode. Window mode allows for one range of temperature monitoring and two point mode allows for two ranges.
Note: This product is rated for use up to 140 °C. Please heed the battery warning. The product will explode if exposed to temperatures above 140 °C.
2
Product User Guide
Installation Guide
Installing the Interface cable
- IFC400 or IFC406 Refer to the “Quick Start Guide” included in the package.
Installing the software
Insert the Software USB stick in an open USB port. If the autorun does not appear, locate the drive on the computer and double click on Autorun.exe. Follow the instructions provided in the Wizard.
Device Operation
Connecting and Starting the data logger
- Once the software is installed and running, plug the interface cable into the docking station.
- Connect the USB end of the interface cable into an open USB port on the computer.
- The device will appear in the Connected Devices list, highlight the desired data logger.
- For most applications, select “Custom Start” from the menu bar and choose the desired start method, reading rate and other parameters appropriate for the data logging application and click “Start”. (Quick Start” applies the most recent custom start options,
Batch Start” is used for managing multiple loggers at once, “Real Time Start” stores the dataset as it records while connected to the logger.)
- The status of the device will change to “Running”, “Waiting to Start” or “Waiting to Manual Start”, depending upon your start method.
- Disconnect the data logger from the interface cable and place it in the environment to measure. Note: The device will stop recording data when the end of memory is reached or the device is
stopped. At this point the device cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Place the logger into the docking station.
- Highlight the data logger in the Connected Devices list. Click “Stop” on the menu bar.
- Once the data logger is stopped, with the logger highlighted, click “Download”. You will be prompted to name your report.
- Downloading will offload and save all the recorded data to the PC.
3
HiTemp140-M12
Wiring the Data Logger
HiTemp140-M12 connector is a 4 pin female M12 connection port which allows the user to change probes as desired. The HiTemp140-M12 will inherit the IP rating of the probe it is attached to, (up to, and including IP68/IP69K).
The HiTemp140-M12 is compatible with probes that have the wiring configuration as shown to the left.
Probe Connection
Connecting probes to the HiTemp140-M12
Materials: 15 mm wrench, Compatible Probe with M12 Connector
1. Connect the probe to the data logger, using the wiring diagram above.
2. Use a 15 mm hex wrench to tighten the threads and secure the probe to the data logger.
4
Product User Guide
Product Maintenance
Battery Replacement
Materials: ER1425S-HT Battery
1. Unscrew the bottom of the logger and remove the battery.
2. Place the new battery into the logger. Note the polarity of the battery.
3. Screw the cover back onto the logger.
Recalibration
The HiTemp140-M12 standard calibrations are two points at 50 Ω and 150 Ω and is verified at 100 Ω.
Pricing:
Recalibration traceable to NIST $70.00 Recalibration only $40.00
Prices and specifications subject to change. See MadgeTech’s terms and conditions at www.madgetech.com To send devices to MadgeTech for calibration, service or repair, please use the MadgeTech RMA Process by visiting
www.madgetech.com, then under the services tab, select RMA Process.
RMA Instructions
To send a device back in to MadgeTech, follow the instructions below to create an RMA (Return Merchandise Authorization) on the MadgeTech website:
1. Visit www.madgetech.com, under the Services tab select RMA Process.
2. When the web page opens, please sign in. If this is the first time, select Click here to register an account and create one. Once signed in, click on the Make New RMA
button and fill in all the blank fields.
3. Complete the applicable fields on the form including customer Billing and Shipping information, even if they are the same. Please see the field explanation below for a more detailed description about questions asked in the Device Information section.
4. When all of the fields are complete, click Generate RMA.
5. Print out the confirmation page that follows containing the RMA number and MadgeTech’s address for shipping. A Return Merchandise Authorization must be accompanied by a copy of the RMA paperwork and shipping is prepaid by the customer. The RMA number should be clearly marked on the outside of the package.
6. Please ship the package via UPS, FedEx, TNT, or DHL to the address listed on the
confirmation page. USPS will not ship MadgeTech data loggers.
7. A notification email will be automatically sent when MadgeTech has received the RMA.
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE, FORCE OVER DISCHARGE, CRUSH, PENETRATE, OR INCINERATE. BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 150ºC (302ºF).
See MadgeTech’s terms and conditions at www.madgetech.com
5
Specifications subject to change.
HiTemp140-M12
HiTemp140-M12 General Specifications
Temperature Sensor Various RTD Probes with M12 Connector (Sold Separately)
Measurement Range
Temperature Resolution
Calibrated Accuracy
*Calibrated
Accuracy Range
Connector Type M12 Female, 4 Pin
Reading Rate 4 readings per second up to 1 reading every 24 hours
Memory 43,690 readings
Start Modes
Stop Modes Manual or Timed (specific date and time)
Trigger Settings
Readings in Trigger
Settings Mode
Real Time Recording May be used with PC to monitor and record data in real time
Password Protection
Memory Wrap Around Yes
Battery Type 3.6V high-temperature lithium battery included; user replaceable
Battery Life 2 years typical (1 minute reading rate)
Calibration Digital calibration through software
Calibration Date Automatically recorded within device
Data Format Date and time stamped °C, °F, °R, K
Time Accuracy ±1 minute/month at 25 ºC
Computer Interface IFC400 or IFC406 USB docking station required; 125,000 baud
Operating System
Compatibility
MadgeTech Software
Compatibility
Operating Environment
IP Rating
Dimensions (body) 2.15 in x 0.97 in x 0.97 in (54.5 mm x 24.6 mm x 24.6 mm)
Dimensions (probe) Probe dependent
Materials Body: 316 Stainless Steel
Approvals CE
*Calibrated accuracies based on standard MadgeTech calibrations for 0 Ω to 200 Ω range.
18 Ω to 400 Ω
-200 °C to +850 °C (-328 °F to +1562 °F) (Probe Dependent)
0.0001 Ω
0.01 °C (0.018 °F) (Probe Dependent)
±0.015 Ω ±0.05 °C (±0.09 °F) (Probe Dependent)
18 Ω to 200 Ω
-200 °C to +265 °C (-328 °F to +509 °F)
• Software programmable immediate start
• Delay start up to 18 months in advance
High & Low limits may be set. Once data meets or exceed sets limits, the device will record to memory. Bi-level start and stop triggers can also be programmed. Users can specify the number of readings to take after the device triggers.
18,724 readings
An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password.
XP SP3/Vista/Windows 7/Windows 8
• MadgeTech Standard Software version 4.2.5.0
• MadgeTech Secure Software version 4.2.4.0 or later
-40 ºC to +140 ºC (-40 ºF to +284 ºF), 0 %RH to 100 %RH non-condensing,
0.002 PSIA to 60 PSIA
IP40 - logger alone (with no probe connected). The logger will inherit IP rating of the attached probe (up to, and including IP68/IP69K).
Weight 85 g (3.0 oz)
6
MadgeTech, Inc.
6 Warner Road
Phone 603.456.2011
www.madgetech.com
l
Warner, NH 03278
l
Fax 603.456.2012
l
info@madgetech.com
DOC-1312036-00 REV 1 2015.06.29