MadgeTech Event101A Data sheet

EVENT101A
EVENT DATA LOGGER
Features
• 10 Year Battery Life
• 4Hz Reading Rate
• Multiple Start/Stop Function
• Ultra High Speed Download
• 406,323 Events Storage Capacity
• Memory Wrap
• Battery Life Indicator
• Optional Password Protection
• Field Upgradeable
Benefits
• Simple Setup and Installation
• Minimal Long-Term Maintenance
• Long-Term Field Deployment
Applications
• Monitoring Gas, Water or Electric
Meters
• Rainfall Monitoring
• Contact Closure Monitoring
• Time Studies
• Traffic Studies
capability, 406,323 reading storage capacity, optional memory wrap, battery life indicator,
optional password protection and more. The Event101A is priced at $99 each and can be
delivered from stock now. Our research has shown that the Event101A is second to no other
data logger when it comes to price and performance.
Using the MadgeTech Software, starting, stopping and downloading from the Event101A
is simple and easy. Graphical, tabular and summary data is provided for analysis and data
can be viewed in multiple units, using the Engineering Units function. The data can also be
automatically exported to Excel® for further calculations.
As the leader in low power data logger technology, MadgeTech continuously improves its
products and develops solutions to meet ever-changing challenges. The Event101A was
designed with our customers in mind. MadgeTech offers free firmware upgrades for the life
of the product so that data loggers already deployed in the field can grow with new
technological developments. Units do not need to be returned to the factory for upgrades.
The user can do this automatically from any PC.
MADGETECH DATA LOGGER SOFTWARE
The Event101A is one of MadgeTech’s newest data loggers.
It is part of a new series of low cost, state-of-the-art data
logging devices. MadgeTech has taken the lead in offering
the most advanced, low cost, battery powered data loggers
in the world today.
The Event101A offers a 10 year battery life, 4Hz reading rate,
Key
A Graph View
B Tabular Data View
C Statistics
D Digital Calibration
E Copy to Excel®
B
A
Software Features:
E
D
C
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
• Multiple graph overlay
• Statistics
• Digital calibration
• Zoom in/ zoom out
• Lethality equations (F0, PU)
• Mean Kinetic Temperature
• Full time zone support
• Data annotation
• Min./Max./Average lines
• Data table view
• Automatic report generation
• Summary view
• Multilingual
EVENT101A SPECIFICATIONS*
Input Connection: Removable screw terminal
Input Range: 0 to 30V
Input Low: <0.4V
Input High: >2.8V
Internal Weak Pull-Up: <60µA
Input Impedance: >60kΩ
Minimum Input Active
(Low) Time:
Time Resolution: 4Hz (reading rate selectable in software)
Reading Rate**: 4Hz to 1 every 24 hours
Memory:
Wrap Around: Yes
Start Modes:
Multiple Start/Stop Mode:
Stop Modes:
Multiple Start/Stop Mode
Activation:
Real Time Recording:
LED Functionality:
10 Microseconds
406,323 readings; software configurable memory wrap
Immediate start
• Delay start up to 18 months
• Multiple pushbutton start/stop
Start and stop the device multiple times without having to download data or communicate with a PC
• Manual through software
• Timed (specific date and time)
To start the device:
Press and hold the pushbutton for 5 seconds, the green LED will flash during this time. The device has started logging.
To stop the device:
Press and hold the pushbutton for 5 seconds, the red LED will flash for three seconds and then the green LED will flash for two seconds. The device has stopped logging.
The device may be used with PC to monitor and record data in real-time
Green LED blinks:
10 second rate to indicate logging 15 second rate to indicate delay start mode
Red LED blinks:
10 second rate to indicate low battery and/or full memory
An optional password may be programmed into
Password Protection:
the device to restrict access to configuration options. Data may be read out without the password.
Native measurement units can be scaled to
Engineering Units:
display measurement units of another type such as on/off, open/closed or rainfall.
Battery Type: 3.6V lithium battery included; user replaceable
Battery Life:
Time Accuracy:
10 years typical, dependent upon frequency and duty cycle.
Graph display of the device recording in a 25°C environment.
±1 minute/month (at 20ºC/68ºF, stand alone data logging)
Computer Interface: USB (interface cable required); 115,200 baud
Software: XP SP3/Vista/Windows 7/Windows 8
Operating Environment:
-40ºC to +80ºC (-40ºF to +176ºF), 0%RH to 95%RH non-condensing
Dimensions: 1.4” x 2.2” x 0.6” (36mm x 56mm x 16mm)
Weight: 0.9 oz (24 g)
Materials: ABS Plastic
Approvals: CE
BATTERY WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT RECHARGE,
DISASSEMBLE, HEAT ABOVE 212ºF, INCINERATE OR EXPOSE CONTENTS TO WATER.
*SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.SPECIFIC WARRANTY AND REM­EDY LIMITATIONS APPLY. CALL 1-603-456-2011 OR GO TO WWW.MADGETECH.COM FOR DETAILS.
**Device will record 1 event per reading interval.
ORDERING INFORMATION
MODEL DESCRIPTION PRICE (U.S.)
EVENT101A Event Data Logger $99.00
IFC200 Software, manual and USB interface cable $119.00
LTC-7PN Replacement battery for Event101A $10.00
For Quantity Discounts call 603-456-2011 or email sales@madgetech.com
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
ASK ABOUT OUR OTHER
DATA
LOGGERS
Temperature
Humidity
Pressure
pH
Level
Shock
LCD Display
Pulse/Event/State
Current Voltage
Wireless
Intrinsically Safe
Spectral Vibration
Motion
REV 4 2013.12.10
Loading...