ETR101A
EXHAUST TEMPERATURE SYSTEM
Features
• 10 Year Battery Life
• 1 Second Reading Rate
• Multiple Start/Stop Function
• Ultra High Speed Download
• 500,000 Reading Storage Capacity
• Memory Wrap
• Battery Life Indicator
• Optional Password Protection
• Programmable High and Low
Alarms
• Field Upgradeable
Benefits
• Simple Setup and Installation
• Minimal Long-Term Maintenance
• Long-Term Field Deployment
Applications
• Profile exhaust temperature of
on-road vehicles and off-road
equipment
The ETR101A is an Exhaust Temperature
Profiling Kit designed to profile the exhaust
temperature of on-road vehicles and off-road
equipment, including tractor trailers, buses,
trucks over 14,000 lbs., waste water vehicles,
and sweepers. The ETR101A comes assembled
and includes a data logger, temperature
sensor (thermocouple type K), weatherproof
enclosure, interface cable, hex screwdriver
and software. A ¼” NPT coupler and a
compression fitting is required for assembling, but not included.
Setup is fast and easy. The ¼” NPT coupler is attached to the exhaust pipe; the use of a compression
fitting allows for the thermocouple to be placed directly in the exhaust stream, providing for highly
accurate profiling. The data logger, which is contained within the weatherproof enclosure, is then
mounted to the vehicle.
Using the MadgeTech software, the logger is programmed to record for a set period, generally three
to five days. Data is stored in the data logger, and is downloadable at any time via a pc or laptop
computer. The complete temperature profile is then provided to the diesel particulate filter (DPF)
manufacturer, aiding in the selection of the correct DPF for the exhaust system.
Many DPF manufacturers, including Donaldson Corp., recommend the use of temperature profiling
equipment, such as the MadgeTech ETR101A, to aid in the selection of the appropriate diesel particulate
filter.
MADGETECH DATA LOGGER SOFTWARE
A
Key
A Graph View
B Tabular Data View
C Statistics
D Digital Calibration
E Copy to Excel®
B
C
E
D
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
Software Features:
• Multiple graph overlay
• Statistics
• Digital calibration
• Zoom in/ zoom out
• Lethality equations (F0, PU)
• Mean Kinetic Temperature
• Full time zone support
• Data annotation
• Min./Max./Average lines
• Data table view
• Automatic report generation
• Summary view
• Multilingual
ETR101A SPECIFICATIONS*
Internal Channel
Temperature Range: -40°C to +80°C (-40°F to +176°F)
Temperature Resolution: 0.1°C (0.18°F)
Calibrated Accuracy: ±0.25°C (±0.45°F)
Remote Channel
Thermocouple Types: K**
Thermocouple Connection: Pluggable screw terminal
Cold Junction Compensation: Automatic based on internal channel
Max. Thermocouple Resistance: 100Ω
Thermocouple Type: Range (°C) Resolution Accuracy
K -270 to +899 0.1°C ±2°C
* Thermocouple accuracy is specified with a 24 AWG
Reading Rate: 1 reading every second to 1 every 24 hours
500,000 readings; software configurable
Memory:
memory wrap
250,000 readings in multiple start/stop mode
or trigger settings mode
Wrap Around: Yes
• Immediate start
Start Modes:
• Delay start up to 18 months
• Multiple pushbutton start/stop
Stop Modes:
• Manual through software
• Timed (specific date and time)
Start and stop the device multiple times
Multiple Start/Stop Mode:
without having to download data or communicate with a PC
To start the device:
Press and hold the pushbutton for 5 seconds,
the green LED will flash during this time. The
Multiple Start/Stop Mode
Activation:
device has started logging.
To stop the device:
Press and hold the pushbutton for 5 seconds,
the red LED will flash during this time. The
device has stopped logging.
Real Time Recording:
The device may be used with PC to monitor
and record data in real-time
Alarm: Programmable high and low limits;
alarm is activated when temperature reaches
or exceeds sets limits.
Alarm:
Alarm Delay: A cumulative alarm delay
may be set in which the device will activate
the alarm (via LED) only when the device
has recorded a user specified time duration
of data.
**Use of stainless steel braided thermocouples with the Waterbox101A may allow water to wick in
through the cable and cause damage to the data logger.
ORDERING INFORMATION
MODEL DESCRIPTION
ETR101A
Calibration Certificate Calibration Certificate available for data logger
LTC-7PN Replacement battery for ETR101A
For Quantity Discounts call 603-456-2011 or email sales@madgetech.com
Exhaust Temperature Recording System Type K Thermocouple included. Other types available
upon request. Contact MadgeTech for details.
High and Low limits may be set for the thermocouple channel. Once data meets or exceed sets limits,
Trigger Settings:
the device will record to memory. Bi-level start and
stop triggers can also be programmed. Users can
specify the number of readings to take after the
device triggers.
Green LED blinks:
10 second rate to indicate logging
15 second rate to indicate delay start mode
LED Functionality:
Red LED blinks:
10 second rate to indicate low battery and/or
full memory
1 second rate to indicate an alarm condition
An optional password may be programmed into
Password Protection:
the device to restrict access to configuration options. Data may be read out without the password.
Battery Type: 3.6V lithium battery included; user replaceable
Battery Life: 10 years typical at a 15 minute reading rate
ETR101A
Graph display of the device recording in a 25°C environment.
Data Format: Date and time stamped °C, °F, K, °R; µV, mV, V
Time Accuracy:
±1 minute/month
(at 20ºC, stand alone data logging)
Computer Interface: USB (interface cable required); 115,200 baud
Software: XP SP3/Vista/Windows 7/Windows 8
Operating Environment: -20°C to +80ºC (-4°F to +176°F), 0 to 100%RH
IP Rating: IP65
Data Logger: 1.4”x2.2”x 0.6” (36mm x 56mm x 16mm)
Dimensions:
Waterbox: 3.5”x2.9”x1.1” (87mm x 73mm x 27mm)
Thermocouple Wire: 24 gauge, 30 inches (762mm)
Thermocouple Probe: 6”x1/8” dia. (153mm x 3.2mm)
Weight: Complete Kit: 9.5oz (269g)
Approvals: CE
BATTERY WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT,
CHARGE, FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE.
BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 80°C (176°F).
*SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC WARRANTY AND
REMEDY LIMITATIONS APPLY. FOR DETAILS CALL 1-603-456-2011.
Temperature
ASK ABOUT
OUR OTHER
DATA
LOGGERS
Humidity
Pressure
pH
Level
Shock
LCD Display
Pulse/Event/State
Current
Voltage
Wireless
Intrinsically Safe
Spectral Vibration
Motion
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
REV 17 2014.01.31