Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Product Information Card
Description EggTemp
Temperature Sensor Internal semiconductor
Temperature Range 0 °C to +60 °C (+32 °F to +140 °F)
Temperature Resolution 0.1 °C
Temperature Accuracy ±0.3 °C
Memory 32,767 Readings
Reading Rate 1 reading every 2 seconds up to 1 reading every 12 hours
LED Indicator Red & Green
Required Interface Package IFC102 or IFC202
Baud Rate 38,400
Typical Battery Life 1 year
Operating Environment
Submergible
Material
Dimensions
Weight 2.02 oz (60 g)
Approvals -
0
°C
to +60
°C
(+32
°F to +140 °F)
Yes
Enclosure: HDPE
Logger: Stainless Steel
2.25 in x 1.68 in dia. (57.15 mm x 42.67 mm)
EggTemp
, 0 %RH to 100 %RH
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 60 °C (140 °F).
See MadgeTech’s terms and conditions at www.madgetech.com
Specifications subject to change.
MadgeTech, Inc.
6 Warner Road
Phone 603.456.2011
www.madgetech.com
l
Warner, NH 03278
l
Fax 603.456.2012
l
info@madgetech.com
DOC-1201035-00 REV 9 2015.03.13
EggTemp
Egg Temperature Data Logger
To view the full MadgeTech product line,
visit our website at www.madgetech.com.
EggTemp
Product Notes
Getting Started
The EggTemp is designed to thermally respond to an environment the same way a real egg
does, simulating the experience of the actual product.
To start the data logger, unscrew the enclosure to access the data logger. The
communication port is located on the end of the data logger. Tighten the enclosure to
ensure a waterproof seal.
LEDs
Once started, the green LED will flash at the selected reading rate to indicate that the
device is running. The red LED will flash in one second intervals if there is an alarm
condition.
Alarm Settings
To change the settings for the temperature alarm:
- Select Alarm Settings from the Device menu in the MadgeTech software. A window will
appear allowing the customer to set the high and low temperature alarms.
- Press Change to edit the values.
- Check Enable Alarm Settings to enable the feature. The values can be entered in the
field manually or by using the scroll bars.
- Click Save to save the changes. To clear an active alarm, press Clear Alarm.
O-Rings
O-ring maintenance is a key factor when properly caring for the EggTemp. The o-rings
ensure a tight seal and prevent liquid from entering the inside of the device.
Please refer to the application note “O-Rings 101: Protecting Your Data”, found on the
MadgeTech website, for information on how to prevent O-ring failure.
Installation Guide
Installing the Interface cable
- IFC202
Insert the device into a USB port. The drivers will install automatically.
- IFC102
Plug the serial cable into the port and verify it is secure.
- USB-1 or USB-101
Install the USB drivers from the USB Software Stick provided in the kit, then plug the USB
cable into the computer and the serial cable into the serial port.
Installing the software
Insert the Software USB into an open USB port. If the autorun does not appear, locate the
drive on the computer and double click on Autorun.exe. Follow the instructions provided
in the Wizard.
Connecting the data logger
- Once the software is installed and running, plug the interface cable into the data logger.
Product Information Card
- Click the Communication Menu, then Auto Configure Port.
- After a moment, a box will appear stating that a device has been found.
- Click OK. The Device Status box will appear. Click OK.
- At this point, communications have been configured for your logger. These settings can
be found under the Communication Menu.
Note: For additional installation instructions refer to your “Data Logger & Software Operating Manual”.
Device Operation
Starting the data logger
- Click Device Menu then Start Device.
- Choose the desired start method.
- Choose the start parameters by selecting a Reading Rate suitable for your application.
- Enter in any other desired parameters and click Start.
- A box will appear stating the data logger has been started. Click OK.
- Disconnect the data logger from the interface cable and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the device
cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Connect the data logger to the interface cable.
- Click the Device Menu then Read Device Data. This will offload all recorded data onto
the PC.
Device Maintenance
Battery Replacement
Materials: Replacement Battery (SR1154W)
- Remove the data logger from the egg enclosure
- Unscrew the knurled endcap on the data logger
- Tip the batteries (enclosed in a plastic sleeve) out of the enclosure tube.
- Use a small, dull, non-metallic tool (e.g. pen cap) to push the batteries out of the sleeve.
- Press the new batteries into the sleeve negative (-) end first.
- Place the sleeved batteries in the enclosure tube positive (+) end first.
- Screw the knurled cap back in place.
Recalibration
The EggTemp standard calibration is one point at 25 °C.
Pricing:
Recalibration traceable to NIST $70.00
Recalibration $40.00
Call for custom calibration options to accommodate specific application needs.
Prices and specifications subject to change. See MadgeTech’s terms and conditions at www.madgetech.com
To send devices to MadgeTech for calibration, service or repair, please use the MadgeTech RMA Process by visiting
www.madgetech.com, then under the services tab, select RMA Process.