MadgeTech CTL2000 Specifications

CTL2000
CARCASS TEMPERATURE DATA LOGGER
Features
• IP67, dust proof and splash proof
• Pushbutton or programmable start
• Channel naming for location
detection
Benefits
• Simple Setup and Installation
• Minimal Long-Term Maintenance
• Long-Term Field Deployment
Applications
• Carcass Temperature Monitoring
during Pasteurization
• Verification and Validation of
Pathogen Reduction
MadgeTech’s redesigned CTL2000 Carcass Temperature data logger is a rugged, one of a kind solution for temperature monitoring during carcass pasteurization cycles. Equipped with eight thermocouple ports, the CTL2000 monitors and records the temperatures of various sections of the carcass during pasteurization, providing a continuous and accurate temperature profile to verify and validate that harmful microorganisms are effectively depleted.
Measuring only eight inches in length and weighing only three pounds, the CTL2000 is easy to handle and hangs securely from the carcass by a single stainless steel hook. This device is capable of withstanding temperatures from -20 °C to 100 °C (-4 °F to +212 °F), allowing it to monitor the entire pasteurization process.
Each channel of the CTL2000 can store up to 129,024 readings which aids in the logging of multiples cycles. Reading rate capabilities range from as fast as four readings per second or as infrequently as one reading every 24 hours. The CTL2000 operates on user replaceable batteries and features a pushbutton start option directly on the device. Delayed start is user programmable from within the MadgeTech Software for up to six months in advance.
The MadgeTech software offers a wealth of data display and reporting options to easily analyze the results of each cycle and provide verification for USDA regulation compliance.
MADGETECH DATA LOGGER SOFTWARE
A
Key
A Graph View
B Tabular Data View
C Statistics
D Digital Calibration
E Copy to Excel®
B
C
Software Features:
E
D
Multiple graph overlay
Statistics
Digital calibration
Zoom in/ zoom out
Lethality equations (F0, PU)
Mean Kinetic Temperature
Full time zone support
Data annotation
Min./Max./Average lines
Data table view
Automatic report generation
Summary view
Multilingual
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
CTL2000 SPECIFICATIONS*
Temperature
8 Internal Channels
Internal Channel
Temperature Sensor:
Temperature Range: -20 °C to +100 °C (-4 °F to +212 °F)
Temperature Resolution: 0.01 °C (0.018 °F)
Calibrated Accuracy: ±0.5 °C (+10 °C to +80 °C)
8 Remote Channels
Remote Channel
Temperature Sensor:
Thermocouple Connection Type: Female Subminiature (SMP)
Cold Junction Compensation: Automatic, based on internal channel
Thermocouple
Temperature Range:
Temperature Resolution: 0.1 °C (0.18 °F)
Calibrated Accuracy: ±0.5 °C (±0.9 °F)
BATTERY WARNING: FIRE, EXPLOSION AND SEVERE BURN HAZARD. DO NOT RECHARGE,
DISASSEMBLE, HEAT ABOVE 100 °C (212 °F), INCINERATE, CRUSH, OR EXPOSE CONTENTS TO WATER.
Semiconductor
Compatible with Type K Only
(Thermocouples sold separately)
-270 °C to +1370 °C (-454 °F to +2498 °F)
ORDERING INFORMATION
*SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC WARRANTY REMEDY LIMITATIONS
APPLY. CALL 1-603-456-2011 OR GO TO WWW.MADGETECH.COM FOR DETAILS.
Reading Rate: 4 readings every second up to 1 reading every 24 hours
Memory: 129,024 readings per channel
Green LED:
LED Functionality:
Start Modes:
Password Protection:
Memory Wrap Around: Yes
Battery Type: (2) 3.6V lithium battery included; user replaceable
Battery Life: 4 years typical at a 5 minute reading rate
Calibration:
Calibration Date: Automatically recorded within the device
Data Format: Date and time stamped ºC, ºF, K, ºR, mV, V
Time Accuracy: ±1 minute/month
Computer Interface: IFC200 USB (Interface cable required)
Operating System
Compatibility:
MadgeTech Software
Compatibility:
Operating Environment:
IP Rating: IP67
Dimensions: 8.1 in x 6.5 in x 3.1 in (205 mm x 165 mm x 80 mm)
Weight: 3.1 lb (49 oz)
Materials:
• Blinks every 2 seconds to indicate unit is logging
• Blinks every 5 seconds to indicate unit is in delay start mode
Software programmable immediate start, pushbutton or delay start up to six months in advance.
An optional password may be programmed into the device to restrict access to configuration options. Data may be read without the password.
MadgeTech recommends annual factory calibration. Digital calibration within the software is also available.
XP SP3/Vista/Windows 7/Windows 8
• Standard Software version 4.2.5.0 or later
• Secure Software version 4.2.4.0 or later
Continuous use: -20 °C to +100 °C (-4 °F to +212 °F) 0 %RH to 100 %RH
• Enclosure & Hook: 316 Stainless Steel
• Gasket Seal: EPDM rubber (NSF-51)
MODEL DESCRIPTION
CTL2000 Carcass Temperature Monitoring Data Logger
(Thermocouple Bundle)
CTL2000
TC-K-60-3-125 Probe
(3” sheath)
TC-K-60-6-188 Probe
(6” sheath)
IFC200 Software, Manual and USB interface cable
Calibration Certificate Calibration Certificate available for data logger
TLH-5903 Replacement battery for CTL2000
For Quantity Discounts call 603-456-2011 or email sales@madgetech.com
Carcass Temperature Monitoring Data Logger with 8 type K thermocouple probes with a 3 or 6 inch sheath
Type K Thermocouple assembly. 60 in PFA wire with a 1/8 in dia. 3 in Stainless Steel Sheath
Type K Thermocouple assembly. 60 in PFA wire with a 1/8 in dia. 5.75 in Stainless Steel Sheath
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
Temperature
ASK ABOUT OUR OTHER
DATA
LOGGERS
DOC1203009-00 REV 4 2015.05.06
Humidity
Pressure
pH
Level
Shock
LCD Display
Pulse/Event/State
Current Voltage
Wireless
Intrinsically Safe
Spectral Vibration
Motion
Loading...