MadgeTech Bridge101A Data sheet

BRIDGE101A
BRIDGE/STRAIN GAUGE DATA LOGGER
Features
• Multiple Start/Stop Function
• Ultra High Speed Download
• 1 Million Reading Storage Capacity
• Memory Wrap
• Battery Life Indicator
• Optional Password Protection
• Programmable Alarm
• Field Upgradeable
Benefits
• Simple Setup and Installation
• Minimal Long-Term Maintenance
• Long-Term Field Deployment
Applications
• Strain Gauge
• Load Cell
• Pressure Transducer
• Torque Sensors
• Load Bolts
• Position Transducer
The Bridge101A Data Logger measures and records voltage, typically used in conjunction with strain gauges, load cells or other low-level DC voltage sources. This device is designed to accurately measure and record the output of the gauge to determine parameter levels such as stress, torque, strain, and pressure on a structure or item over a period of time.
Available in three different measurement ranges (±30 mV, ±160 mV or ±1200 mV), the Bridge101A offers a reading rate of up to 4 Hz with memory capacity of 1,000,000 readings (memory wrap optional). The device can be configured to start at a specified date and time up to 24 months in advance and the pushbutton start/stop feature allows the user to initiate or cease logging data in the field if desired.
The MadgeTech Data Logger Software offers user programmable Engineering Units which allows collected data to be presented in the established unit being measured. Equipped with endless data analysis and reporting tools, the MadgeTech software simplifies device management and provides the user with graph, tabular or summary reports with the ability to export data to Excel as needed.
MADGETECH DATA LOGGER SOFTWARE
A
Key
A Graph View
B Tabular Data View
C Statistics
D Digital Calibration
E Copy to Excel®
B
C
E
D
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
Software Features:
Multiple graph overlay
Statistics
Digital calibration
Zoom in/ zoom out
Lethality equations (F0, PU)
Mean Kinetic Temperature
Full time zone support
Data annotation
Min./Max./Average lines
Data table view
Automatic report generation
Summary view
BRIDGE101A SPECIFICATIONS*
*SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC WARRANTY REMEDY LIMITATIONS
APPLY. CALL 1-603-456-2011 OR GO TO WWW.MADGETECH.COM FOR DETAILS.
Nominal Range: ±30 mV ±150 mV ±1000 mV
Measurement
Range:
±30 mV ±160 mV ±1200 mV
Resolution: 1 µV 5 µV 50 µV
Calibrated
Accuracy:
±0.01% FSR;
±3 Microvolts
±0.01% FSR;
±16 Microvolts
±0.01% FSR;
±120 Microvolts
Input Range: 0 to 2.5V 0 to 2.5 V 0 to 2.5 V
Reference Voltage: 2.5 V 2.5 V 2.5 V
Reading Rate: 4Hz to 1 every 24 hours
• 1,000,000 readings; software configurable
Memory:
memory wrap
• 330,000 readings in multiple start/stop
Wrap Around: Yes
• Immediate start
Start Modes:
• Delay start up to 24 months
• Multiple pushbutton start/stop
Stop Modes:
Multiple Start/Stop
Mode:
• Manual through software
• Timed (specific date and time)
Start and stop the device multiple times without having to download data or communicate with a PC.
• To start the device: Press and hold the pushbutton for 5 seconds, the green LED will flash during this time. The device has
Multiple
started logging.
Start/Stop Mode
Activation:
• To stop the device: Press and hold the pushbutton for 5 seconds, the red LED will flash during this time. The device has stopped logging.
Real Time
Recording:
The device may be used with PC to monitor and record data in real time
• Green LED blinks: 10 second rate to indicate logging 15 second rate to indicate delay start
LED Functionality:
• Red LED blinks: 10 second rate to indicate low battery and/or full memory 1 second rate to indicate an alarm condition
ORDERING INFORMATION
Password
Protection:
An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password.
Native measurement units can be scaled to display
Engineering Units:
measurement units of another type. This is useful when monitoring voltage outputs from different types of sensors such as strain gauges and load cells.
Battery Type: 3.6V lithium battery included; user replaceable
10 months typical at a 1 minute reading rate with a 350 load
2 years typical at a 1 minute reading rate with a 1000 load
*Battery Life:
Time Accuracy:
±1 minute/month (at 20 ºC/68 ºF, stand alone data logging)
Computer Interface: USB (interface cable required); 115,200 baud
Software:
Operating Environment:
XP SP3/Vista/Windows 7/Windows 8 (MadgeTech 4 Only)
-40 ºC to +80 ºC (-40 ºF to +176 ºF), 0 %RH to 90 %RH non-condensing
Dimensions: 1.4 in x 2.5 in x 0.6 in (36 mm x 64 mm x 16 mm)
Weight: 0.8 oz (24 g)
Materials: ABS Plastic
Approvals: CE
*MadgeTech recommends using 350 or 1000 strain gages. 120 strain gauges can be used with the Bridge101A but it is not recommended as it will reduce the battery life, potentially increase noise level and limit the low end temperature operation.
BATTERY WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT RECHARGE,
DISASSEMBLE, HEAT ABOVE 212 ºF, INCINERATE OR EXPOSE CONTENTS TO WATER.
MODEL DESCRIPTION
Bridge101A-30 ±30 mV Bridge/Strain Data Logger
Bridge101A-150 ±150 mV Bridge/Strain Data Logger
Bridge101A-1000 ±1000 mV Bridge/Strain Data Logger
Calibration Certificate Calibration Certificate available for data logger
IFC200 Software, manual and USB interface cable
LTC-7PN Replacement battery for Bridge101A
For Quantity Discounts call 603-456-2011 or email sales@madgetech.com
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
Temperature
ASK ABOUT OUR OTHER
DATA
LOGGERS
DOC 1242009-00 REV 10 2015.04.14
Humidity
Pressure
pH
Level
Shock
LCD Display
Pulse/Event/State
Current Voltage
Wireless
Intrinsically Safe
Spectral Vibration
Motion