Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Description Bridge101A
Range
See Table Below*Resolution
Accuracy
Memory
Wrap Around Yes
Reading Rate 4Hz to 1 every 24 hours
LED Indicator Red and Green
Units V, mV, µV, Engineering Units specified through software
Required Interface IFC200
Baud rate 115,200
*Battery Life
Operating Environment -40 °C to +80 °C (-40 °F to +176 °F), 0 %RH to 90 %RH non-condensing
Material ABS plastic
Dimensions 1.4 in x 2.5 in x 0.6 in (36 mm x 64 mm x 16 mm)
Weight 0.8 oz (24 g)
Approvals CE
*MadgeTech recommends using 350 or 1000 Ω strain gages. 120 Ω strain gauges can be used with the Bridge101A but
it is not recommended as it will reduce the battery life, potentially increase noise level and limit the low end temperature
operation.
1,000,000 readings; software configurable memory wrap
330,000 readings in multiple start/stop
10 months typical at a 1 minute reading rate with a 350 Ω load
2 years typical at a 1 minute reading rate with a 1000 Ω load
Product Information Card
Bridge101A
*Bridge101A Range, Resolution and Accuracy
Nominal Range ±30 mV ±150 mV ±1000 mV
Measurement Range ±30 mV ±160 mV ±1200 mV
Resolution 1 µV 5 µV 50 µV
Calibrated Accuracy
Input Range 0 to 2.5V 0 to 2.5 V 0 to 2.5 V
Reference Voltage 2.5 V 2.5 V 2.5 V
±0.01% FSR;
±3 Microvolts
±0.01% FSR;
±16 Microvolts
±0.01% FSR;
±120 Microvolts
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT,
CHARGE, FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE.
BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 80 °C (176 °F).
See MadgeTech’s terms and conditions at www.madgetech.com
Specifications subject to change.
MadgeTech, Inc.
6 Warner Road
Phone 603.456.2011
www.madgetech.com
l
Warner, NH 03278
l
Fax 603.456.2012
l
info@madgetech.com
DOC 1242035-00 REV 16 2015.04.14
Bridge101A-30
30mV Bridge Data Logger
Bridge101A-150
150mV Bridge Data Logger
Bridge101A-1000
1000mV Bridge Data Logger
To view the full MadgeTech product line,
visit our website at www.madgetech.com.
Bridge101A
Product Notes
The Bridge101A Data Logger measures and records voltage, typically used in conjunction
with strain gauges, load cells or other low-level DC voltage sources. This device is designed to
accurately measure and record the output of the gauge to determine parameter levels such as
stress, torque, strain, and pressure on a structure or item over a period of time.
Available in three different measurement ranges (±30 mV, ±160 mV or ±1200 mV), the
Bridge101A offers a reading rate of up to 4 Hz with memory capacity of 1,000,000 readings
(memory wrap optional). The device can be configured to start at a specified date and time
up to 24 months in advance and the pushbutton start/stop feature allows the user to initiate
or cease logging data in the field if desired.
*MadgeTech recommends using 350 or 1000 Ω strain gages. 120 Ω strain gauges can be used with the
Bridge101A but it is not recommended as it will reduce the battery life, potentially increase noise level and
limit the low end temperature operation.
LEDs
- Green LED: every 10 seconds to indicate logging and 15 seconds to indicate delay
start mode.
- Red LED: every 10 seconds to indicate low battery and/or memory and 1 seconds to
indicate an alarm condition.
Installation Guide
Installing the Interface cable
- IFC200
Insert the device into a USB port. The drivers will install automatically.
Product Information Card
- Disconnect the data logger from the interface cable and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this
point the device cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Connect the logger to the interface cable.
- Highlight the data logger in the Connected Devices list. Click “Stop” on the menu bar.
- Once the data logger is stopped, with the logger highlighted, click “Download”. You will
be prompted to name your report.
- Downloading will offload and save all the recorded data to the PC.
Device Maintenance
Battery Replacement
Materials: Small Phillips Head Screwdriver and a Replacement Battery (LTC-7PN)
- Puncture the center of the back label with the screw driver and unscrew the enclosure.
- Remove the battery by pulling it perpendicular to the circuit board.
- Insert the new battery into the terminals and verify it is secure.
- Screw the enclosure back together securely.
Recalibration
Bridge101A standard calibration values:
Logger Voltage 30 mV 150 mV 1000 mV
Installing the software
Insert the Software USB Stick in an open USB port. If the autorun does not appear, locate
the drive on the computer and double click on Autorun.exe. Follow the instructions
provided in the Wizard.
Device Operation
Connecting and Starting the data logger
- Once the software is installed and running, plug the interface cable into the data logger.
- Connect the USB end of the interface cable into an open USB port on the computer.
- The device will appear in the Connected Devices list, highlight the desired data logger.
- For most applications, select “Custom Start” from the menu bar and choose the desired
start method, reading rate and other parameters appropriate for the data logging
application and click “Start”. (“Quick Start” applies the most recent custom start options,
“Batch Start” is used for managing multiple loggers at once, “Real Time Start” stores the
dataset as it records while connected to the logger.)
- The status of the device will change to “Running”, “Waiting to Start” or “Waiting to
Manual Start”, depending upon your start method.
Strain (V) 0 V and 22.5-25 mV 0 V and 90-100 mV 0 V and 900-1000 mV
Pricing:
Recalibration $40.00
Call for custom calibration options to accommodate specific application needs.
Prices and specifications subject to change. See MadgeTech’s terms and conditions at www.madgetech.com
To send devices to MadgeTech for calibration, service or repair, please use the MadgeTech RMA Process by visiting
www.madgetech.com, then under the services tab, select RMA Process.