AVS150
Features
Enables compliance with FDA 21
CFR Part 11
Software calculates thermal
resistance in F0
N.I.S.T. traceable calibration
Stand alone, complete system
No thermocouple wires
Digital calibration through software
Package Includes:
1 or 5 HiTemp150’s with
N.I.S.T. certificates
IFC200 interface package
Secure Software License
IQ/OQ/PQ Validation Protocols
1 or 5 Thermal Shield(s) rated to
250°C
AUTOCLAVE VALIDATION SYSTEM
The AVS150 is a complete system
used to perform autoclave
validations. The AVS150
consists of a N.I.S.T. traceable
HiTemp150 da t a log ger, a n
IP68 extended range thermal
shield, an IFC200 USB cable
package and MadgeTech’s FDA
21 CFR Part 11 Secure Softwa re .
For larger size autoclaves or
mapping projects, the AVS150-5,
inc ludes five HiTemp150’s and
five thermal shields.
The HiTemp150 is completely submersible and can measure temperatures up to 150°C.
The 2” rigid probe provides a fast response time and can record readings as fast as once
per second. The HiTemp150 can be used in each autoclave cycle for verification and to
provide data for validation. When used with the thermal shield the device can withstand
up to 250°C (time dependent).
MadgeTech’s Secure Software provides data in graphical and tabular form, and provides
a summary and statistical report of the data. The software also features sterilization
calculations to determine the F0 value. Furthermore the software allows for different user
levels and logins, electronic signatures, an audit trail and a secure data file to stand up to
auditors.
Key
A Administrator Settings
B Electronic Signatures
C Digital Calbration
D Data Summary/Statistics
E Audit Trail View
Features & Benefits
of using MadgeTech
Secure Software
• Install, validate and operate
one software program
universally
• Compatible with all
MadgeTech products
• Time and cost saving validation
package, stands up to
interrogation from auditors
• Data Security and audit trail
is automatic
• Advanced user maintenance
• Traceability with customizable
audit trails and electronic
signatures
• Aids in compliance with
FDA 21 CFR Part 11/820
and GxP guidelines
MadgeTech Secure Data Logger Software
Enables compliance with FDA 21 CFR Part 11
A
E
879 Maple Street · Contoocook, NH 03229
PO Box 50 · Warner, NH 03278 · Phone: (603) 456-2011 · Fax: (603) 456-2012
D
B
C
HITEMP150 SPECIFICATIONS*
Temperature Sensor:
Temperature Range:
Temperature Resolution:
Calibrated Accuracy:
Start Modes:
Memory:
Reading Rates:
Calibration:
Calibration Date:
Battery Type:
Battery Life:
Data Format:
THERMAL SHIELD SPECIFICATIONS
Operating Environment:
IP Rating:
Ambient Temperature Time In Air To Max Internal Temp (150ºC / 302ºF) Time In Liquid To Max Internal Temp (150ºC / 302ºF)
-200°C (-328°F) 18 minutes N/A
-180°C (-292°F) 19 minutes N/A
-160°C (-256°F) 21 minutes N/A
-140°C (-220°F) 24 minutes N/A
-120°C (-184°F) 27 minutes N/A
-100°C (-148°F) 32 minutes N/A
-80°C(-112°F) 40 minutes N/A
-40°C to +150ºC (-40°F to +302ºF) Indefinitely Indefinitely
-60°C (-76°F) 55 minutes 25 minutes
160ºC (320ºF) 75 minutes 34 minutes
170ºC (338ºF) 63 minutes 29 minutes
180ºC (356ºF) 55 minutes 26 minutes
190ºC (374ºF) 50 minutes 23 minutes
200ºC (392ºF) 45 minutes 21 minutes
210ºC (410ºF) 42 minutes 19 minutes
220ºC (428ºF) 39 minutes 18 minutes
230ºC (446ºF) 36 minutes 17 minutes
240ºC (464ºF) 34 minutes 16 minutes
250ºC (482ºF) 32 minutes 15 minutes
100Ω Platinum RTD
-40 to +150ºC
0.05ºC
±0.5ºC
Software Programmable
Start Now
Delay Start
32,767 readings
1 second up to 12 hours
Digital Calibration through software
Automatically recorded within
Device
3.9V high-temperature lithium
battery included
1 year typical
(1 minute reading rate @ 25°C)
Date and time stamped ºC, ºF, K, ºR
-200 to +250ºC (-328 to +482ºF)
Time limited, 0 to 100% RH
IP68
Time Accuracy:
Computer Interface:
Software:
Operating Environment:
Dimensions (Body):
Dimensions (Probe)*:
Weight:
Material:
Approvals:
*SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC WARRANTY AND REMEDY LIMITATIONS APPLY. CALL
1-603-456-2011 OR GO TO WWW.MADGETECH.COM FOR DETAILS.
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT
SHORT CIRCUIT, CHARGE, FORCE OVERDISCHARGE, DISASSEMBLE,
CRUSH, PENETRATE OR INCINERATE. BATTERY MAY LEAK OR
EXPLODE IF HEATED ABOVE 150° C (302° F).
Dimensions:
Weight:
±1 minute/month at 20ºC
(RS232 cable not in use)
PC serial or USB (Interface cable
required); 2,400 baud
XP SP3/VIsta/Windows 7
Not Compatible with 64 bit systems
-40 to +150ºC, 0 to 100%RH
1.1” x 1.75” dia. (28mm x 45mm dia.)
2.0” x 3/16” dia. (50mm x 5mm dia.)
*
Other probe lengths available
HiTemp150: 8 oz (225g)
AVS150: 60.9oz (3.8lbs, 1.72 Kg)
AVS150-5: 134.5oz (8.4lbs, 3.81Kg))
316 Stainless Steel
CE
2.1” x 2.6” dia.
53.34mm x 66mm dia.
.65lb
ORDERING INFORMATION
Model
AVS150
AVS150-5
AVS150-Custom
Includes (1) HiTemp150 data logger with N.I.S.T.
Calibration Certificate, an extended range thermal
shield, IFC200 interface cable, MadgeTech’s FDA 21 CFR Part
11 Secure Software and IQ/OQ/PQ validation protocols.
Includes (5) HiTemp150 data loggers with N.I.S.T.
Calibration Certificate, (5) extended range thermal
shields, IFC200 interface cable, MadgeTech’s FDA 21 CFR
Part 11 Secure Software and IQ/OQ/PQ validation protocols.
Includes a custom number of HiTemp150 data
logger with N.I.S.T. Calibration Certificate, extended range
thermal shields, IFC200 interface cable, MadgeTech’s FDA
21 CFR Part 11 Secure Software and IQ/OQ/PQ
validation protocols.
PO Box 50 · Warner, NH 03278 · Phone: (603) 456-2011 · Fax: (603) 456-2012
Description
Price (U.S.)
$2,085.00
$4,200.00
Call For Pricing
879 Maple Street · Contoocook, NH 03229
ASK ABOUT OUR OTHER
DATA RECORDERS
Temperature
Humidity
Pressure
pH
Level
Shock
LCD
Pulse/Event/State
Low Level Current
Low Level Voltage
RF Transmitters
Intrinsically Safe
Spectral Vibration