Madell QK982 Operating Manual

MADELL QK982 SYRUP DISPENSER
The QK982 syrup dispenser can be used with different syrups as glues, greases, solder pastes, etc. Supplied with 10 types of steel tips and 5 types of plastic tips for various applications.
OPERATING MANUAL
1.Specifications
combinations
Dispensing Time 0.01-99.99 seconds adjustable
Timing Intervals 0.1-9.9 seconds adjustable
Repeat Tolerance ±0.05%
Size 23.8X15.0X6.0cm
Weight 1.7Kg
Internal Voltage 24V DC Air Input 35-100Psi(0.25-0.7MPa)
Air Output 1-100Psi(0.01-0.7Mpa)
2.Operation
(1) Features
1. Power Switch, unit on or off switch.
2. Timing Interval switch, timing intervals control.
3. Air Pressure Regulator, air pressure control.
4. Vacuum Control, ”suck back vacuum control.
5. Air Pressure Gauge, air pressure indicator.
6. Dispense Outlet, quick connect receptacle.
7. Dispensing Sliding Switch, syrup output and time interval control
8. Air-in Tube, compressed air input
9. Footswitch.
10. Model Switch, manual, automatic and other modes selection.
11. Power Connector.
(2).Diagram of front and rear panels
e
12345
50
6
0
4
0
3 4
0 3
2
0 2
5
1
0 1
0
7
0
VACUUM
7 0
+-
8 0
6
9
0
100
AI R PRESSUREINTERVAL
DISPENSING TI ME
ON
OFF
67
FUSE 0. 25
SETUP
10 9811
FOOTSWIRTCH
PSI MAX
100
0.7 MPa MAX AIR IN
(3)Adjustment of dispensing time and interval time
Mode switch on the rear panel of the unit can be adjusted according to th following table to suit different needs.
(a). Adjustment of dispensing time and interval time.
The dispensing time control button is located on the front panel of the unit.
The dispensing time can be set directly. Press the “+” button, and the corresponding digit will increase by one. Similarly, press the “- ”button, the corresponding digit will decrease by one. There are four digits in the display, with a range from 0.01 second to 99.99 seconds, and the resolution is 0.01 second.
(b). Interval Time Setup
The interval time control button is located on the front panel of the unit.
The interval time can be set directly. Press the “+” button will increase the interval by one. Similarly, press the “- ”button will decrease the interval by one. There are two digits in the display, with a range from 0.1 second to 9.9 seconds, and the resolution is 0.1 second.
ON
12 43
Item No.
Mode Switch Status S1 S2 S3 S4
Function
With pedal switch pressed, dispense
1 OFF OFF OFF OFF
continuously, otherwise it will stop dispensing.
2 ON OFF OFF OFF
3 OFF ON OFF OFF
4 ON ON OFF OFF
5 OFF OFF ON OFF
6 ON OFF ON OFF
7 OFF ON ON OFF
8 ON ON ON OFF
9 OFF OFF OFF ON
10 ON OFF OFF ON
11 OFF ON OFF ON
12 ON ON OFF ON
13 OFF OFF ON ON
Be triggered once, dispense at controlled time once. Be triggered once, dispense at controlled time twice. Be triggered once, dispense at controlled time three times. Be triggered once, dispense at controlled time four times. Be triggered once, dispense at controlled time five times. Be triggered once, dispense at controlled time six times. Be triggered once, dispense at controlled time seven times. Be triggered once, dispense at controlled time eight times. Be triggered once, dispense at controlled time nine times. Be triggered once, dispense at controlled time ten times. Be triggered once, dispense at controlled time eleven times. Be triggered once, dispense at controlled time twelve times. Be triggered once, dispense at controlled time
14 ON OFF ON ON
continually, the next trigger will stop dispensing.
15 OFF ON ON ON
16 ON ON ON ON
With pedal switch pressed, dispense at controlled time continually, or it will stop dispensing. Dispense at controlled time continually and automatically.
Note: Dispensing at controlled time means dispensing according to set dispensing time and interval time.
(4)Internal air pressure control
The air pressure regulation knob controls internal air pressure. Air pressure at 0.1-2.7bar (1-40Psi) is normally used.
(5)Vacuum control
The vacuum control knob regulates the ending dot in the air reflection, avoid connected dots. Turn the knob clockwise will increase air reflection , otherwise, it will decrease.
(6)Set up
1. Connect the 7 bar dry and filtered air supply to the unit’s air input plug.
2. Fill the barrel with syrup. Make sure the syrup level is not over the FULL
line,
(6)Operation
1. Turn the unit “on” by switching the red power to on position.
2. Pull the air pressure regulator knob outward and turn clockwise until the desired air pressur e is in di ca te d.
3. Set the mode switch to proper position, referring to the adjustment of dispensing time and interval time .
3. Helpful hints for making Proper de posit
1. Hold the barr el at approximately 60℃(+ or -20℃) angle(FI G1)
2. Lift the dispenser barr el vertically after making a drop, as shown (FIG2)
3. Do not let the syr up flow back into the controller as shown in FIG3.
4. Increase or decre ase dot size by ei t h er, Increas e or decr ease time only,
Or In crea se or de creas e press ure onl y,
Or
Increase or de creas e size of the ti p.
FIG.1
FIG.2
COMPRESSED AI R
AI R HOSE
QUICK982B
DISPENSOR
BARREL ADAPTER ASSEMBLY
60°
FIG.3
FOOT SWITCH PLUG
.
POWER CORDBARREL STAND
4. Cautions
1. The dispensed syrup maybe toxic and/or hazardous, refer to manufacturer’s instructions for proper handling and safety precautions.
2. Compr essed air pressure s hould not ex ceed 7 bar (100 Psi). Oth erwise, it wi ll cause negative effects (damage to objects or injury to the user).
3. Make certain air suppl y is clean and dr y.
4. Syru p should be ke pt above 5 to avoid change in density. Otherwise, the syrup will be hard to dispense and proper dots can not be for med.
5. Th e air pressure should be r egula t ed at 0.1-0. 27Mpa ( 15-40Psi).
7. Clean the dispenser tip reg ul arly.
8. The suck-back vacuum should be adjusted in conjunct ion with air pressure, dispensing
cycle and drop size. Too stronger vacuum will break the dispensed lines, cause running back of the syrup through the controller, resulting in permanent damages to the unit.
9. Avoid turning barrels upside down or lay down on its side. Syrup may run t hrough
air li ne to insid e of the di s penser and ca use comp onent damages.
10. Avoid hit the plastic barrel assemblies with hot or sharp objects.
11. Avoid exposing the dispenser to excessive moisture or solvent.
12. After use, clean t he barrel and needles as soon as possibl e by soaking them in clean
water for 5-10 minutes.
3. The dispensing controller electrical schematic
1. Parts List
Symbol Description Part No. F1 Fuse, 0.25Amp P1 Potentionmeter 47087 P2 Controlling PCB 47166 S1 Solenoid Valve 26036 SW1 Power switch 12034 SW2 Foot pedal switch 47024 SW3 Time setup switch 12040 SW4 Mode Switch (DIP Switch) 47164 TR1
Transformer 110V/24V 18035 Transformer 220V/24V 18036 Transformer 230V/24V 18037
4. The dispens ing controller pneumatic system.
1. Parts List Symbol Description Part No. 1 Solenoid valve 26034 2 Dispensing socket 47165 3 Air pressure gauge 26035 4 Vacuum regulator 47163 5 Air pressure regulator 26036 6 Air-in manifold 44122
BLUEBROWN
SW2
+
-
BLA CK
WHI TE WHI TE
P2
BLACK
S1
BROWN
SW3
TI ME SET UP
PUSH WHEEL SWITCH
F1
SW1
TR1
2 4V AC
SW4
ON
RED
WHI TE
BROWNBLCK
+ -
P1
1. Electrical Theory Schematic
1
3
7
5
6
4
1.Theory Schematic of pneumatic system.
5. Trouble sho ot ing
Problem Check or correction No power 1.Check wall socket for power supply
2.Check fuse.
3.U nplu g from wal l. r emove top cove r ,vis uall y inspe ct for
any loose or shor t connection. Power on, but no light replace power switch Power light on, does 1.C heck foot switch con nection. not ope r at e 2.Unpl ug f rom p owe r su ppl y, remove t op cove r an d ch e ck for
loose connection. Power light on, does 1.Check air supply and pressure gauge.
not dispense reset the regulator if necessary, remove barrel from
adapter .Depress foot switch to check air flow.
2.If s ol en oi d cl ogge d w it h for e ign ob j e ct fr om ai r comp r es s or, clean or replace it.
Solen oid buzzes 1.Voltage is too low
2.Air supply is insufficient.
3.Solenoid is not clean.
Burnt fuse 1.Checking fuse specifications.
2.Unplug power input, remove cover, and check internal
wiring for loose connection. Inconsistent dots 1.Check needles tip, barrel, adapter and material for possible
clogging.
2.Check for air bubbles in the syrup.
3.C heck ai r gauge for air pressure va riation. Dispensing ok, but 1.Check vacuum setting. no vacuum in 2.Check air pressure setting(must be dispense circuit 30-40Psi,0.2-0.27Mpa )
6. Parts list
No. Description Unit Quantity Part No. 1 Piston piece 1 25023 2 35cc barrel piece 1 25024 3 35cc adapter
(+1.0m clean tube) 4 Needle(10pieces/set) set 1 25025 5 Power cable
6 Foot switch ( i nclude two c or es plug) set 1 47024 7 “O” ring piece 1 26041 8 Instruction manual set 1 9 Barrel rack piece 1 43035 10 Air-input tube (3m) set 1 26040 11 Adapter (match the barrel which cannot be
connected with the adapter)
CCC USA VDE/CE
200-240V/0.25A piece 12 Fuse 110V/0.5A piece
set 1 47089
piece 1
piece 1 42073
1