Madell QK870 User Manual

MADELL QK870
PRE-HEAT/REFLOW HOT PLATE
1. Specification:
Heating Power: 800W
Plate Area: 180mmx200mm
Plate Material: AL
Weight: 5kg
2. Features:
Even temperature distribution.
CPU closed loop temperature control, digital display, zero Voltage heater switching.
Dedicated power and heating switches.
ESD safe.
External temperature calibration.
Hinged hood creates an oven like environment for reflow.
Two heating states optional (Pre-heating reflow).
3. Operation:
Plug the power cable.
Turn on the power switch.
Pre-heat plate temperature will be displayed after the set temperature is displayed for 2
seconds.
Adjust the up or down arrow keys to change the set temperature (see temperature
adjustment).
Turn on the heating switch, the unit starts heating. It will reach the set temperature in a few
minutes.
The unit may be used as a pre-heat plate when the cover is moved back or as a mini reflow
oven when the cover is over the plate.
Turn off the heating switch after a circuit board is done.
Turn off the power switch at the end of the work.
Note: Be aware of the high temperature on the plate and its surrounding areas.
4. Temperature Setting and Adjustment
Temperature can be set in two ways:
(a). Regular setting:
Turn the heating switch off.
Press the ‘*’ key for at least 1 second.
th
1) The 100
mode. The 100
2) Use the ‘’ or‘▼’keys to go through the valid numbers as shown below:
While the desired number is displayed, press the ‘*’ key to enter it and switch to the 10
digit position. The 10
3) Use the ‘’ or ‘’ keys to cycle through the valid numbers as shown below:
1 2 3 4 5 6 7 8 9 0
Press the *key to enter the desired number and switch to the 1th digit position.
4) Change to the desired number as show in (3).
At the ‘*’ key is pressed at the 1th digit,
a) The selected temperature is saved;
b) It is displayed.
c) It is applied to the heating element.
digit flashes. It indicates that the unit has entered into temperature setting
th
digit may be changed.
1 2 3 4
th
digit flashes.
th
Notes: if power is off during temperature setting, the new temperature will not be
saved.
If the “*” key is pressed less than 1 second, the set temperature will be displayed for 2
seconds. Display will be automatically switched back to pre-heat plate temperature.
After the ‘*’ is pressed, power supply to heating elements will be out off.
If an invalid temperature is entered, the 100
needed.
th
digit will flash, indicating a valid temperature is
(b). Temperature Setting during Heating
If it is necessary to change plate temperature quickly while power supply to heat element is still
maintained, the following procedure can be followed:
Raising the temperature:
Press the ‘key directly without pressing the “*” key. Doing so will raise the set temperature 1. If the ‘key is released, it will not respond to new input within 2 seconds. Press the ‘’ key again after two seconds will raise the temperature another 1℃.
If the ‘▲’key is pressed for least 1 second, the set temperature will be incremented automatically until the‘▲’key is released.
Lowering the temperature:
Similar to above, the ’ key is used instead.
5. Parts list:
Item
No.
Part
No.
Part Name
1 42059 Handle of screw nut
2 43052 Reflow cover
3 Fuse/10A 125V
Fuse/5A 250V
4 12013 Grounding
5 11008 Power cord
6 43053 Top cover
7 44158 Support column
M4x10( 8)
8 47118 Heating accessories
9 44159 Pad loop
10 44160 Screw nut
M4x12 ( 6)
11 43054 Bottom holder
12 18046 Transformer 110V-13V
18045 Transformer 120V-13V
18044 Transformer 220V-13V
13 44161 Power socket
14 47119 P.W.B
15 44162 Power cover
16 12017 Switch (black)
17 12021 Switch (red)
18 44163 Temperature extrude plate
19 45030 Rubber pad
20 43055 Bottom plate
21 25027 Waterproof connector