Macurco Protect & Prevent Specsheet

3M Occupational Health and Environmental Safety Division
3M™ Macurco™ Fixed Gas Detection
Protect
& Prevent
Fixed gas detecting equipment for residential and commercial applications.
Combustible Gas Detectors
For Homes, Furnace Rooms, Commercial Buildings, Energy Management Systems
GD-1-SPC-NG /
GD-1D GD-1S GD-2A GD-21
GD-1-SPC-PRO
Gas detector for use with alarm systems. Available in two calibration options: 20% LEL Propane or 20% LEL Methane.
• Flush or surface mount
• 12-24 VAC or VDC operation
• SPDT alarm relay
• N.C. trouble relay
Gas detector for use with alarm systems, dual relay output. Standard calibration 10% LEL and 25% LEL Methane.
• Flush mount
• 12-24 VAC or VDC operation
• High and low level
alarm relays
Gas detector for use with alarm systems, or 12VDC boats, motor homes, and alternately fueled vehicles (i.e. propane, hydrogen, etc.).
• Surface mount
• 12 VDC operation
• N.O. alarm relay
UL listed combustible gas detector for use with fire and security alarm systems.
• Flush or surface mount
• 12-24 VAC or VDC operation
• SPDT alarm relay
• N.C. trouble relay
• UL listed to UL 2075
• Alarm set point: Per UL 1484 (25% LEL)
GT-11A GT-11 4S1D-1-BR 4S1-GVC
Analog gas transducer for
use with HVAC/Building
Automation Systems.
• NEMA 1 Enclosure
• 24 VAC or VDC operation
• 1-5V or 4-20mA output
• Compatible with DVP-120
• 0 to 20% LEL range
• Color: Gray
Analog gas transducer for
use with HVAC/Building
Automation Systems.
• 24 VAC or VDC operation
• 1-5V or 4-20 mA output
• 0 to 20% LEL range
• Color: White
Combustible gas detector for use in commercial applications with 120 VAC operation requirement.
• 120 VAC operation
• 85 dBA buzzer
• N.O. alarm relay
• Alarm set point: 25% LEL
natural gas (methane)
• Mounts to double gang box
• Optional 220 VAC operation (Model: 4S1D-1-BR-220)
Gas valve controller for propane and natural gas. Gas valve sold separately through
HVAC or gas suppliers.
• 24 VAC operation
• 85 dBA alarm buzzer
• N.C. relay powers 24V gas
valve
• Alarm Level: 10% LEL of
propane and natural gas
• Class Two System: low voltage operation
Easy to install stand-alone heating gas detector for residential use.
• 120 VAC operation
• 85 dBA buzzer
• Alarm set point: 25% LEL
natural gas (methane)
Note: Standard calibration of combustible gas detectors can detect the following gases: methane, LP, natural gas, propane, butane and gasoline vapors.
Control Panel for Fixed Gas Detectors
For Multi-Point Applications Such As Parking Garages, Warehouses, Maintenance Facilities
DVP-120 SS103-3A
Gas detection and ventilation control panel with externally visible LCD display showing the status of each transducer and relay.
• 120 VAC operation
• Adjustable alarm settings and time delays
• Three 16 Amp, 240 VAC SPDT fan/alarm relays
• Accepts 4-20mA input from up to 12 CO, NO2 or LEL gas sensors
• Externally visible LED status indicators
• Lockable NEMA 1 type enclosure
• 24VDC drivers for external horn and strobe
• Internal buzzer, 90 dBA at 1ft
Note: nished good model numbers are the same as the part numbers for ordering purposes.
CO ventilation controller to monitor up to three (SS103-3A)
remote transducers.
• 120 VAC operation
• Adjustable alarm settings
• Three 10 Amp relays
• System status LED’s
• Sturdy electrical box enclosure