TM
Portable Gas Detection Solutions
Portable Gas Detection Solutions
by Macurco
AimSafety by Macurco blends more than
45-years of gas detection innovation and
development into new, advanced gas monitor
solutions that help organizations protect workers
and the community, and increase safety,
compliance and revenue.
PM
PM
100
100
-CO
-H2S
PM
100
Series
Newest, Advanced Disposable Single Gas, Personal
Monitor for CO, H2S, or O
The PM
protects workers by providing exposure detection for specic gases in hazardous
environments. The PM
provides real-time gas concentrations on an easy to read LCD display. A three-tier
alarm system warns the user of the presence of unsafe gas levels with audible,
visual, and vibrating alarms. The PM
(CO), Hydrogen Sulde (H
is a maintenance-free, disposable portable single-gas monitor that
100
Key Features
• Visible calibration status
• Maintenance-free
• Operates continuously for two years
• Single button operation
2
continuously monitors ambient air conditions and
100
has sensor options for Carbon Monoxide
100
S) and Oxygen (O2).
2
Applications
• Oil & gas
• Heavy metal & steel
• Chemical plants
• Pulp & paper
• Event logging
• Rugged, high visual housing
• Easy-to-read LCD display
• IP67 dust tight & water resistant
• 30-day end-of-life warning & notification
-O
PM
100
2
• Municipalities
• Food & beverage
• Contractor / construction
• General industry
www.aimsafety.com

PM
100
Series
Portable Gas Detection Solutions
Portable Gas Detection Solutions
TM
Specifications
Size
Weight
Battery
Operating Period
Event Logging
IP Rating
Display
Alarms
Temperature
Humidity
Certifications
Warranty
Sensor Life
Notification
3.34”(L) x 1.92”(W) x 1.56”(H) *with clip
8.48 cm x 4.87 cm x 3.96 cm
3.3 oz. (93 g.) Toxic models
3.8 oz. (107 g.) O
(Battery, clip included)
Lithium (Non-replaceable)
2 Years*
30 Events (Alarms / bumps)
IP67
LCD display
▪ Audible buzzer - 90 dB (at 4 in. typical)
▪ Vibration alarm
▪ Flashing red LEDs
▪ On-screen indication
▪ Differentiating audible & visual high
and low alarms indication
CO & H
S: -40°F to 122°F (-40°C to 50°C)
2
: -31°F to 122°F (-35°C to 50°C)
O
2
5% to 95% RH (Non-condensing)
UL-913 & CSA-C22.2 No.157
Class 1 Div.1 & 2, Groups A,B,C & D.
ATEX II 1G Ex ia IIC T4 Ga
IECEx Ex ia IIC T4
INMETRO
2-Years From Activation
▪ Sensor life indication screen
(Month(s), days or hours)
▪ <30-Day end-of-life display warning
(Days or hours)
model
2
Gas Options
Gas Range Resolution
CO
H2S
O
2
0 - 500 ppm 1 ppm
0 - 100 ppm
0 - 30% Vol
0.1 ppm
0.1% Vol
Ordering Information
Gas Model Number Low Alarm High Alarm
PM
CO
H2S
O
-CO
100
PM
-H2S
100
PM
-O
2
100
2
100 ppm35 ppm
15 ppm10 ppm
23.5% 19.5%
Accessories
Name Model Number
PM Link
Bump/Cal Test Station
Bump/Cal Test Station PM Link
PM-Link
PM
100
-Station
Policy Enforcement
(Configurable)
*Normal Alarm Use: Based On Two Minutes Of Alarm Per Day
▪ End-of-life notification
▪ Alarm test due
▪ Bump test due
▪ Calibration due
Since 1972 Macurco has been providing gas detection solutions for various
applications. Macurco provides the highest quality gas detection solutions to
customers worldwide.
Macurco Gas Detection
3601 N St. Paul Ave,
Sioux Falls, SD 57104
Phone: 1-877-367-7891
Website: www.macurco.com
© Aerionics 2019. All rights reserved. Macurco is a trademark of Aerionics, Inc.
ISO 9001:2015
CERTIFIED
Email: info@macurco.com