Macurco Mac-MG-1 Specsheet

MG-1
Portable Multigas Detector
Now with
of pentane and
hexane
Carbon monoxide
Hydrogen sulde
Oxygen
Flammable gases
MG-1
Portable Multigas Detector
Choosing the portable gas detector for your needs
MG-1 integrates innovative safety features and an intuitive, rugged design to provide advanced protection for those working in harsh environments. This portable multigas de­tector, which is exceptionally easy to use and service, protects against the four most preva­lent gas hazards: carbon monoxide (CO), hydrogen sulde (H2S), ammable gases and oxygen (O2) depletion.
ctor NEW Portables
e
t
e
D
s
a
g
i
t
l
u
M
e
l
b
a
M
G
t
r
o
P
1
-
MG-1 Portable
Multigas Detector
The Complete
Solution
Now with
improved detection
of pentane and
hexane
P
r
o
2
.
0
S
o
f
t
w
a
r
e
E
a
s
y
s
e
r
v
i
c
e
a
n
d
c
o
n gura-
From the individual contractor to the
site safety manager, Macurco offers all the tools
I-Te
s
t
&
I
-
T
e
s
t
M
a
n
a
g
e
r
B
u
m
p
t
e
s
t
&
c
needed to manage and maintain a MG-1 eet with
ease, and stay compliant.
a
l
i
b
r
ation solutions
Comprehensive r
ons
i
t
p
o
g
n
i
g
r
a
h
c
d
n
a
s
e
i
r
o
s
s
e
c
c
a
f
o
e
g
n
a
Condence, however you look at it
MG-1 contains a wide range of features to make everyday use easier and safer:
TWA Resume function
Unique to MG-1, this innovative fea­ture ensures toxic gas exposure is cal­culated accurately over an entire shift, even if MG-1 is switched off for a break or during travel to another site.
18 hour battery life
Safely work multiple or longer shifts
between charges, covered by the 18
hour battery life.
Backlit display
Large, clear display with backlight
and option to ip the screen 180° for
easy viewing while worn.
Rugged design
With a thick anti-shock rubber cas­ing and drop tested to ~13.125 ft (4m) on concrete, MG-1 provides dependable operation under the most demanding use. Water & dust resistant to IP65 & IP6 7.
Positive Safety indicator
A simple ‘trafc light’ status indicator
which, at a glance, provides visual assurance of operational and compliance status to both users and supervisors.
Green light - Working safely
Red light - Attention required
Intrinsically safe
ATEX approved and UL Class 1 Div 1 for operation in a wide range of hazardous environments.
Dedicated sensors
One sensor for every gas ensures effective, fast and reliable detection.
Multiple alarms
Audible 95dB alarm, bright red/blue LED’s and vibrating alerts provide effective warning to gas hazards.
Easy operation
Large single button and intuitive menu system minimizes training and allow easy operation while wearing gloves.
TWA Resume
TWA Resume* ensures time weighted average (TWA) toxic gas exposure is calculated accurately over an entire work shift.
The red line on the graph shows workers with other
detectors risking overexposure to hydrogen sulde
(H2S) by switching their detector off for a lunch break.
Only MG-1 provides the option to include previous measurements in the calculation when you switch your detector back on again and so prevent you exceed­ing your exposure limit. Because of TWA Resume
(green line), MG-1 alarms at 14:00 when their 8 hour
TWA reaches 5ppm.
Product Specication
Size
Weight
Durability
Alarms
Display
Logging
Battery
Environment
Compliance
Approvals
Accessories
Audible Vibrating Visible
Data Events
Rechargeable Li-ion
Operating temp Humidity Ingress protection
EMC
ATE X IECEx UL
INMETRO MED
Included with MG-1
Available separately
5.3 x 3.1 x 1.4in (135 x 80 x 35mm)
9.9oz (282g)
Drop tested ~13.125 ft (4m) onto concrete
95dB Integrated Bright red & blue LED’s
Front mounted, backlit, 180° ip for easy viewing while worn
130 hours of data at 10s intervals 3,500
Up to 18 hour runtime; 5.5 hour recharge
-4°F to +131°F (-20 to +55°C)* 10-95% RH @ 104°F (40°C) non-condensing Independently tested to IP65 and IP67
Directive 2014/30/EU
Ex II 2 G Ex d ia IIC T4 Gb Tamb -20°C to +55°C Ex d ia IIC T4 Gb Tamb -20°C to +55°C Use in hazardous locations Class 1 Div 1 groups A,B,C,D only as to intrinsic safety Ex d ia IIC T4 Gb Tamb -20°C to +55°C
Integrated alligator clip and tethering loop Bump/calibration plate
Single unit cradle charger; 10 unit cradle charger; Vehicle charger Clip on dust lter plate I-Test automated bump test and calibration station
Accessories:
Cradle charger
Docking station for easy charging
10 way charger
For charging and storing your
MG-1 eet
*Toxic and oxygen sensors are not rated for continuous operation above 122°F (50°C)
Gases and Ranges:
Gas
Oxygen (O2)
Flammable
Hydrogen sulde (H2S)
Carbon monoxide (CO)
Range
0-30% vol.
0-100% LEL
0-100ppm
0-1000ppm
Resolution
0.1% vol.
1% LEL
1ppm
1ppm
User Options
*Options adjustable using Portables Pro 2.1.7 Software
TWA Resume
Calibration Interval
Bump Interval
Pellistor Saver Mode
TWA/STEL Alarm
Low/High Alarm
180° Flip Display
Event/Data Logging
Macurco reserves the right to change the design or specication of the product without notice.
Latching Alarms
Peak Mode Function
Custom User Message
Force Bump Test When Due
Force Calibration When Due
Audible & Visual Condence
Alert
Auto Zero on Start Up
Languages (11)
www.macurco.com
NEW Portables Pro 2.0 Software
For easy conguration and servicing
External lter plate
Clip-on lter for dusty environments
Aspirator plate
Sample atmosphere prior to entry
Effective charging and storage whilst
Vehicle charger
travelling
I-Te st
Easy automated bump testing and
calibration solution
Bump/calibration plate
To apply test gas to MG-1
©2016. Crowcon Detection Ltd.
Sioux Falls, SD - Phone 1-877-367-7891 - Email: info@aerionicsinc.com - www.macurco.com