Macurco™ GD-2B Combustible Gas Detector User Instructions
Important: These User Instructions are to be provided to the homeowner/end user upon
product installation. Each person installing or using this equipment must read and understand the information in these User Instructions before use. Installation of this equipment by untrained or unqualified persons, or use that is not in accordance with these User Instructions may adversely affect product performance and result in sickness or death. For proper use see User Instructions or call Macurco Technical Service.
1
GENERAL SAFETY INFORMATION INTENDED USE
The GD-2B is a low voltage (9-32VDC, 12-24VAC) electronic detector of combustible, heating type gases. The GD-2B is designed for connection to Fire Alarm/Burglary Control Panels. Alarm control panels that work on 12 or 24 VDC can provide battery backup to the GD-2B detectors. This combustible gas detector has been designed for methane (natural gas) and propane (LP) gas. It is NOT designed to detect smoke, fire or carbon monoxide.
LIST OF WARNINGS AND CAUTIONS
Each person using this equipment must read and understand the information in these
User Instructions before use. Use of this equipment by untrained or unqualified persons, or use that is not in accordance with these User Instructions, may adversely affect product performance and result in sickness or death.
Use only for monitoring the gas which the sensor and detector are designed to
monitor. Failure to do so may result in exposures to gases not detectable and cause sickness or death. For proper use, see supervisor or User Instructions, or call Macurco Technical Service.
GD-2B may not function effectively below 32 F or above 120F. Using the detector
outside of this temperature range may adversely affect product performance and result in sickness or death.
This detector helps monitor for the presence and concentration level of certain
specified airborne gases. Misuse may produce an inaccurate reading, which means that higher levels of the gas being monitored may be present and could result in overexposure and cause sickness or death. For proper use, see supervisor or User Instructions, or call Macurco Technical Service.
The GD-2B is not designed to measure compliance with Occupational Safety and
Health Administration (OSHA) commercial or industrial standards. When the unit is turned on it performs a self-test, which activates the audible and/or visual alarms. If the self-test fails, or all the alarms do not activate, do not use. Failure to do so may adversely affect product performance and result in sickness or death.
Immediately exit the environment if there is an alarm condition on the detector. Failure
to do so may result in sickness or death.
2
This detector will only indicate the presence of combustible gas at the sensor.
Combustible gas may be present in other areas. Accommodation spaces should be well ventilated when household cleaning supplies or similar contaminants are used.
Do not cover or obstruct visual alarm LED. Doing so may adversely affect product
performance and result in sickness or death.
Do not disassemble unit or attempt to repair or modify any component of this detector.
This detector contains no user serviceable parts, and substitution of components may adversely affect product performance and result in sickness or death.
CAUTION
Avoid the use of harsh cleaning materials, abrasives and other organic solvents. Such
materials may permanently scratch the surfaces; damage the sensor, labels, or instrument housing.
If you have any doubts about the applicability of the equipment to your job situation,
consult an industrial hygienist or call Macurco Technical Service.
USE INSTRUCTIONS AND LIMITATIONS
Each person using this equipment must read and understand the information in these User Instructions before use. Use of this equipment by untrained or unqualified persons, or use that is not in accordance with these User Instructions, may adversely affect product performance and result in sickness or death.
USE FOR
The GD-2B is an electronic detector of combustible, heating type gases (natural gas and propane), designed for connection to alarm control panels. It can operate on 12 to 24 VDC power from standby or interruptible panel power, or be powered separately. The GD-2B is intended for installation in buildings in non-hazardous locations such as residences, retail stores, office buildings, and institutional buildings.
Use only for monitoring the gas which the sensor and detector are designed to monitor. Failure to do so may result in exposures to gases not detectable and cause sickness or death. For proper use, see supervisor or User Instructions, or call Macurco Technical Service.
3
DO NOT USE FOR
The GD-2B is NOT intended for use in industrial applications such as refineries, chemical plants, etc. The GD-2B does NOT detect carbon monoxide. Do NOT mount the GD-2B in a corner. The GD-2B is designed for connection to Fire Alarm/Burglary Control Panels. Do not connect the GD-2B to Fire Alarm Circuits, or Burglar Alarm or other signals. The Alarm Control Panel must be dedicated to gas detection or have alarm devices that provide a distinctive alarm for gas detection. Do NOT mount the GD-2B in kitchens or bathrooms - alcohol’s, ammonia, cleaning solvents, paint thinner, gasoline vapors, and aerosol propellants (aerosol cans such as hair spray usually contain a combustible gas) may cause nuisance alarms.
GD-2B may not function effectively below 32 F or above 120F. Using the detector outside of this temperature range may adversely affect product performance and result in
sickness or death. GENERAL DESCRIPTION
The GD-2B is a low voltage (9-32VDC, 12-24VAC) electronic detector of combustible, heating type gases, that has been calibrated for methane (natural gas) and propane (LP) gas. The GD-2B is designed for connection to Fire Alarm/Burglary Control Panels. The GD-2B has a SPST Alarm relay, for connection to control panels or other devices. The GD-2B does NOT detect carbon monoxide. The GD-2B has an optional internal audible sounder.
FEATURES
DESIGNED TO MEET UL STANDARD 2075 FOR THE STANDARD FOR SAFETY
FOR GAS AND VAPOR DETECTOR AND SENSORS
SENSITIVITY TESTED BASED ON UL 1484 STANDARD FOR RESIDENTIAL GAS
DETECTORS
DETECTS HEATING GASES: PROPANE (LP), NATURAL GAS (METHANE) SPST ALARM AND TROUBLE RELAYS CAN BE SELF-RESTORING OR LATCHING ELECTRONIC SENSORS: NO MAINTENANCE OR RECALIBRATION TEMPERATURE COMPENSATED SIMPLE INSTALLATION AND OPERATION SUPERVISED SENSOR