Macurco Gas Detection Selectable, CANN10M Specsheet

Methane, Propane or Hydrogen Gas Detection
The GD-6 is a versatile, easy-to-use device that allows you to select between methane, propane or hydrogen gas detection. It provides low-level detection of combustible gas in an easy-to-maintain monitor that is factory calibrated for simple installation.
This low voltage detector provides automatic feedback and fan control that can help reduce combustible gas concentrations in parking garages, maintenance
facilities, and other locations that require combustible gas detection.
Measurement: Methane (NG), Propane (LP) or Hydrogen (H2)
Output: Fan relay, alarm relay and 4-20 mA current loop
Controls: Digital display (0-50% LEL), buzzer, fan delay,
fan minimum run time
The GD-6 is an advanced combustible gas detector with the selectable options that make it an effective solution for multiple applications that need an accurate combustible gas detector.
3M Occupational Health and Environmental Safety Division
3M Macurco Combustible Gas Detector, Controller and Transducer GD-6
Gas Detection
Selectable
Multiple Output Options
Occupational Health & Environmental Safety Division
3M Center Building 0235-02-W-70 St. Paul, MN 55144-1000 Tec hn ic al S er vi ce : 1- 80 0- 24 3- 46 30 Customer Service: 1-800-328-1667 www.3M.com/OccSafety www.3M.com/detection
3M and Macurco are trademarks of 3M, used under license in Canada.
Please recycle. Printed in USA. © 2011 3M Company All rights reserved. 70-0715-7486-0
Specifications
Accuracy: ±5% of the LEL reading up to 50 % LEL
Power: 3 W (max) from 12 to 24 VAC
or 12 to 48 VDC
Current @ 24VDC: 75 mA in alarm (two relays), 50 mA
(fan relay only) and 23 mA stand by
Shipping Weight: 1 pound (0.45 kg)
Size: 4.5 x 4 x 2.125 in. (11.4 X 11.4 X 5.3 cm)
Color: Dark gray
Connections: Plugs/terminals
Mounting Box: (Not included) 4x4 electric
Fan Relay: 5 A, 240 VAC, pilot duty, SPDT
Fan Relay Actuation: Selectable at 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 (default),
11, 12, 13, 14, 15, 16,17, 18, 19, 20% LEL
Fan Delay Settings: 0, 1, 3 (default), 5 and 10 minutes
Fan Minimum Run Time:
Settings are OFF (default), 3, 5, 10, 15 minutes
Alarm Relay: 0.5A 200 V, 10 VA
Alarm Relay Actuation: Selectable N.O. default or N.C.
Alarm Relay Settings: OFF, 5, 10, 15, 20 (default), 25% LEL
Current Loop: 4-20 mA for 0-50% LEL
Operating Environment:
0 °F to 125 °F (-18 °C to 52 °C) 10 to 90% RH
Combustible Gas Detection
Measures Methane (NG), Propane (LP) or Hydrogen (H2)
Low level meter capable of displaying from 0-50% LEL EX
Display, Control & Calibration
Selectable (on/off) digital display, buzzer, fan delay (minutes),
fan minimum run time
Selectable fan and alarm relay activation
Factory calibrated. Can also be eld calibrated using 10% LEL
Methane, 10% LEL Propane or 10% LEL Hydrogen gas, regulator and calibration hood
One screw allows access for calibration
Installation
Mounts on a standard 4" x 4" electrical box, no cover needed
5 A SPDT fan relay controls starters of exhaust fans
0.5 A N.O. or N.C. alarm relay connects to warning devices
or control panels
4-20 mA current loop
Optional calibration kits allow the GD-6 to be tested and eld
calibrated using Methane, Propane or Hydrogen gas
Other Features
Supervised system design: internal detector problem
will cause the fan & alarm relay to activate
ETL Listed to UL 61010-1
Typical Connection to Alarm Control Panel
GD-6 can be used with 12VDC or 24VDC N.O. (fire) panels
Alarm panel provides battery backed up power to GD-6
GD-6 dry contact fan relay can use panel power or fan power.
Check ratings on panel and fan
Match fan relay contacts to fan size, and coil voltage
to power source
Alarm control panels are available with many features and can
control other devices such as smoke detectors, fire detectors and burglar alarms
Ordering Information
3M ID UPC
Description
70-0716-0802-3 0 00 51131 49886 0 3M Macurco Combustible Gas Detector,
Controller and Transducer GD-6, 1 Each/Case
70-0716-0803-1 0 00 51131 49887 7 3M
Macurco Combustible Gas (EX)
Calibration Hood GD-6-CH, 1/Case
70-0716-1751-1 0 00 51131 49928 7 3M
Macurco Methane Gas Field Calibration Kit 34L, 10% LEL, 34L, 20% LEL, Carry Case, Regulator, Tubing, Calibration Hood GDM-FCK, 1/Case
70-0716-1752-9 0 00 51131 49929 4 3M
Macurco Propane Gas Field Calibration Kit 34L, 10% LEL, 34L, 20% LEL, Carry Case, Regulator, Tubing, Calibration Hood GDP-FCK, 1/Case
70-0716-1753-7 0 00 51131 49930 0 3M
Macurco Hydrogen Gas Field Calibration Kit 34L 10% LEL 34L, 20% LEL, Carry Case, Regulator, Tubing, Calibration Hood GDH-FCK, 1/Case
70-0716-1754-5 0 00 51131 49931 7 3M
Macurco Methane Replacement Gas, 34L, 10% LEL Methane CANN10M, 1/Case
70-0716-1755-2 0 00 51131 49932 4 3M
Macurco Methane Replacement Gas, 34L, 20% LEL Methane CANN20M, 1/Case
70-0716-1756-0 0 00 51131 49933 1 3M
Macurco Propane Replacement Gas 34L, 10% LEL Propane CANN10P, 1/Case
70-0716-1757-8 0 00 51131 49934 8 3M
Macurco Propane Replacement Gas, 34L, 20% LEL Propane CANN20P, 1/Case
70-0716-1758-6 0 00 51131 49935 5 3M
Macurco Hydrogen Replacement Gas, 34L, 10% LEL Hydrogen CANN10H, 1/Case
70-0716-1759-4 0 00 51131 49936 2 3M
Macurco Hydrogen Replacement Gas,
34L, 20% LEL Hydrogen CANN20H, 1/Case
Loading...