Macurco CM-6-AK User Manual

Macurco™ Metal Housing Adapter Kit, CM-6-AK
Installation Instructions
Used to retrofit Macurco Metal Housings (CM-2B, CM-3, ND-2, etc.) for use with Macurco “4x4” type detectors (CM-6, CM-4, CM-21A, etc.)
Contents of this kit: 1 Metal Adapter Plate (with 2 screws installed) and 4 vent caps (Black)
Please refer to the specific detector User Instructions for additional installation information and warnings
1
1. Turn off the power to the old detector and open the detector door.
5. Remove the wires from the printed circuit assembly so that they are free.
2. Unscrew the 4 screws in the corners of the gold colored metal faceplate.
3. Pull out the gold colored metal faceplate and let it hang off the switch wires.
6. Grab the hexagonal spacer in the top left corner and twist to the side so that the spacer breaks off.
7. Break off the spacer on the upper right hand side of the box. Then break off the long hexagonal spacers on the bottom left and right corners.
4. Loosen the screws holding the power and interconnection wires. Make a note of which colored wire goes to which connection.
8. The printed circuit assembly will now be loo s e in the grey metal box. Remove the printed circuit assembly.