Proven Performance
Proven Technology
Proven Support
Information Technology (IT) at the component level!
An Infrared (IR) Combustible Gas Sensor Module is
network-enabled to provide the interface needed to
your plant-wide control system, whether it be 4-20
mA, Modbus, HART, relay contacts or SentryBus.
This USA-made, stand-alone smart gas sensor
module is loaded with features you need. As usual,
Sierra Monitor A gas detector with a Sierra Monitor
pedigree, Factory Mutual approved and ready to
Manage Your Gas Risk. The 5100-28-IT provides
all the built-in features desired by instrumentation
and safety professionals, including:
Sentry IT Gas Sensor Module
IT Combustible - Infrared
• FM Approval for performance and
• SIL-2 Certified
• Modbus RTU RS-485 interface
• 4-20 mA output
• HART interface
• SMC Sentry digital bus interface
• Optional Integral alarm relays – Alarm,
Warning and Trouble
• Aluminum or 316 Stainless Steel enclosure
• Annual calibration frequency
• %LEL or % volume
• Interface to multiple protocols
• Integral scrolling LED display
• Optional remote sensor
The 5100-28-IT can be used as a 4-20 mA
component or as a Modbus RTU node. For higher
level system capability the module can interface
directly to Sierra Monitor’s Sentry Controller. As
part of a Sentry system the user gains capability of
system Modbus serial communications, extensive
diagnostic features, area and zone alarm
management, WebServer interface and multiplexing
sensor connections.
safety
Factory
electrical safety and environmental parameters
including Class I, Div. 1, Groups C, D and Class I,
Zone 1, Group IIC. The 5100-28-IT is also SIL-2
Certified and meets NFPA-72 requirements for gas
detectors.
How It Works
Most combustible gases absorb infrared light
energy at defined wavelengths, providing an
absorption signature for that gas. The principle of
an infrared detector is based upon the absorption of
the infrared light at a specific wavelength as it
passes through the gas. The more of the absorbing
gas that is present, the more light is absorbed. The
detector measures the energy from an infrared light
beam at a wavelength that
and compares it to the energy emitted by the
source. The difference in energy received by the
detector indicates the level of gas in the
atmosphere.
Mutual (FM) Approval for performance,
is absorbed by the gas
Features Benefits
Non-intrusive calibration, menu driven system Able to easily and quickly calibrate module without
declassifying the area
Network compatible with Modbus, 4-20mA, Sentry
bus, HART, relay interface
FM Approved for performance and hazardous
area operation, Class I, Div. 1, Group C, D, with
NEMA 4X enclosure rated for -40
et gnol steeM deifitreC 2-LIS rm reliability design standards
fo esaE yalpsid gnillorcs lacoL calibration and easy access to gas
o
to 176oF areas
Easy to install in a variety of field applications plus
easy to obtain critical safety information wherever
needed
For safe and reliable operation in hazardous areas
concentration, relay status and diagnostics
Distributed by Aerionics, Inc. Sioux Falls, SD – Phone: 1-877-367-7891 – Email: info@aerionicsinc.com – www.macurco.com
Specifications:
Sensor type: Infrared, Dual Wavelength
Performance
Dual Range:
Default: 0-100% LEL Methane
User Setting: 0-100% by vol. Methane
Repeatability: +/-1% LEL
Accuracy: +/- 1% for 0-50% LEL range
+/- 2% for 51-100% LEL range
Zero Drift: +/- 1% full scale per month
@ 20
(max +/- 3% full scale per year)
Sensor Life: Typically >5 years
Heated Sensor: Heated cell to prevent condensation
Response Time: T90<10sec*
Output:
Display: Fixed and Scrolling LED
Signal Outputs: Sentry digital bus
Analog 4-20 mA Linear
3-wire Non-Isolated
4-wire Isolated
Serial RS-485 Modbus RTU
Relay : Optional
Options:
Relays: 5 amp Alarm, Warning (0.25 amp Trouble)
5A@ 250 VAC, 5A@ 30VDC (Alarm, Warning)
Board includes auxiliary connection for Sentry
HART: Termination board includes HART, Modbus RS-
Remote Sensor: Up to 100 feet (30.4m)
Power:
Power consumption: 3 watts
Input voltage: 24 VDC nominal: 10-30VDC
o
C (68oF) ambient,
multiplexing
485, 4-20mA, Digital Input, 2A Relay output, No
Sentry Bus
Sentry IT Gas Sensor Module
IT Combustible - Infrared
Operating Range:
Ambient Temp Range: -40
Relative Humidity: 0-99% Non-Condensing
Construction:
Dimensions: (H x W x D)
(A1 & A2) 7.8 x 5.7 x 3.9 in. (19.8 x 14.5 x 9.9 cm)
(S1 & S2) 7.5 x 4.4 x 4.9 in. (19 x 11 x 12 cm)
Weight:
(A1 & A2) 3.4 lb. (1.5 Kg)
(S1 & S2) 7.2 lb. (3.3 Kg)
Enclosure: Epoxy coated Aluminum or 316 Stainless Steel
Housing: AL or SS (same as enclosure)
Hazardous Area
Classification: Explosion proof, Class 1, Div. I, Groups C, D
Class I, Zone 1
Group IIC, IP66, IP65, NEMA 4X, T6
TA = - 40
Warranty: 2 years
Approvals:
ATEX II 2 G, Ex d IIB+H2 T6 Gb, Ta = -20
FM Approval 6320 Combustible Gas Detector Performance
FM Approval 3600 Class I Div. 1, Groups C, D
SIL-2 Certified Certified by Lloyd's Register (IEC 61508)
CSA For enclosure in hazardous locations
ABS Certificate of Compliance
CQST Certificate for China
CCOE/PESO Certificate for India
Specifications subject to change without notice
* T60<10 sec NRTL Approved option for noise suppression
o
to 140oF (-40o to 60oC)
o
C to 85oC II2 GD, Ex d IIC
o
C to 60oC
Ordering Information:
Relay/Connection
Model Enclosure
5100-28-IT - XX - XX -
- A1 = AL ¾” NPT - 01 = No Relays (std) - 01 = Methane (Std.) - 0 = Standard - 0 = None - F = FM
- A2 = AL M20 x 1.5 - 02 = Relays Option - 2 = Conformal - 1 = Remote - C = ATEX
- S1 = SS ¾” NPT - 05 = HART Option Transmitter Sensor
- S2 = SS M20 x 1.5
Accessories:
5311-00 Rainshield
5311-02 Rainshield with calibration port
Calibration Accessories:
5358-01 Calibration Head, Standard
5360-00 Calibration Gas Delivery Fitting
Calibrators High Capacity:
1250-01 Gas Sensor Calibration Kit, Type A
1260-02 Combustible Gas 50% LEL Gas Cylinder Type A
Output
Gas Type
X -
Manufactured by
Sensor
Protection
Remote
Option Approvals
- X -
Distributed by Aerionics, Inc. Sioux Falls, SD – Phone: 1-877-367-7891 – Email: info@aerionicsinc.com – www.macurco.com