Macurco 5100-03-IT Specsheet

GAS DETECTION
Sentry IT Gas Sensor Module
IT Toxic Gas
180 Day Calibration Interval
Network enabled toxic gas detection
Information Technology (IT) at the component level! A network enabled Gas Sensor Module with the brilliance to provide Sentry, 4-20 mA or Modbus output. This is a stand alone module with the intelligence to provide integral alarms, loaded with features you need. A gas detector with a Sierra Monitor pedigree, Factory Mutual approved and ready to manage your gas risk. The 5100-XX-IT Series provides all the built-in features desired by instrumentation and safety professionals, including:
FM Approval for performance and safety  180 day calibration frequency  SIL-2 Certified  Modbus RTU RS-485 interface  4-20 mA output  HART Interface  SMC Sentry digital bus interface  ATEX Approved (5100-05-IT)  IECE
x Certified (5100-05-IT)
Optional Integral alarm relays – Alarm,
Warning and Trouble
Aluminum or 316 Stainless Steel enclosure  Integral scrolling LED display  Remote alarm reset  Optional remote sensor
The 5100-XX-IT can be used as a 4-20 mA component or as a Modbus RTU node. For higher level system capabilities the module can interface directly to Sierra Monitor’s Sentry Controller. As part of a Sentry system the user gains capability of system Modbus serial communications, extensive diagnostic features, area and zone alarm management, WebServer interface and multiplexing sensor connections.
O
2
CO H
S
2
Cl
2
ClO SO
2
NO
2
NH
3
HF HCl
180 Day Calibration Interval
Factory Mutual (FM) Approved for electrical safety and environmental parameters including Class I, Div. 1, Groups B, C, D and Class I, Zone 1, Group IIB+H2 IP66. The 5100-XX-IT is also SIL Certified and meets NFPA-72 requirements for gas detectors.
How It Works
Electrochemical sensors are fuel cell-like devices consisting of an anode, cathode and electrolyte. The components of the cell are selected so a subject gas, allowed to diffuse into the cell, will cause a chemical reaction and generate a current. The cells are diffusion limited so the rate the gas enters the cell is solely dependent on the gas concentration. The current generated is proportional to the rate of the consumption of the subject gas in the cell.
2
Features Benefits
sulp snoitacilppa dleif fo yteirav a ni llatsni ot ysaE yalpsid gnillorcs lacoL
easy to obtain critical safety information wherever needed
Non-intrusive calibration, menu driven system Able to easily and quickly calibrate module without
declassifying the area
FM Approved for performance and hazardous area
operation, Class I, Div. 1, Group B, C, D, with NEMA 4X enclosure rated for -40
o
to 122oF areas
Flexible Modbus, 4-20mA, Sentry bus, HART and
relay interface
For safe and reliable operation in hazardous areas 5100-05-IT also includes FM Approval for
performance Easy to install in a variety of field applications plus
easy to obtain critical safety information wherever needed
S rm reliability design standards
et gnol steeM deifitreC 2-LI
Distributed by Aerionics, Inc. Sioux Falls, SD – Phone: 1-877-367-7891 – Email: info@aerionicsinc.com – www.macurco.com
Sentry IT Gas Sensor Module
IT Toxic Gas
GAS DETECTION
Specifications:
Gas Type Model
Std.
Range
(1)
Opt. Max
Range
Resolution
Response
(2)
Time
Accuracy
Oxygen 5100-03-IT 5-25 %Vol 25 %Vol 0.1% <10 sec. +/- 0.2% - 4 to 122 -20 to 50 15 – 99% Carbon Monoxide 5100-04-IT 0-500 PPM 1200 PPM 0.5 PPM <35 sec. +/- 1 PPM - 4 to 122 -20 to 50 15 – 90% Hydrogen Sulfide 5100-05-IT 0-100 PPM 100 PPM 0.1 PPM <35 sec. +/- 3 PPM - 40 to 122 -40 to 50 15 – 90% Chlorine 5100-06-IT 0-10 PPM 10.0 PPM 0.1 PPM <60 sec. +/- 0.5 PPM - 4 to 122 -20 to 50 15 – 90% Chlorine Dioxide 5100-08-IT 0-3 PPM 3.0 PPM 0.1 PPM <60 sec. +/- 0.5 PPM - 4 to 122 -20 to 50 15 – 90% Sulfur Dioxide 5100-10-IT 0-100 PPM 100 PPM 0.5 PPM <20 sec. +/- 0.5 PPM - 4 to 122 -20 to 50 15 – 90% Nitrogen Dioxide 5100-12-IT 0-20 PPM 20.0 PPM 0.2 PPM <35 sec. +/- 0.5 PPM - 4 to 122 -20 to 50 15 – 90% Hydrogen Chloride 5100-21-IT 0-20 PPM 20.0 PPM 0.1 PPM <100 sec. +/- 0.1 PPM - 4 to 122 -20 to 45 15 – 90% Ammonia 5100-25-IT 0-100 PPM 100 PPM 1.0 PPM <30 sec. +/- 1 PPM + 14 to 113 -10 to 45 20 – 95% Hydrogen Fluoride 5100-26-IT 0-10 PPM 10 PPM 0.5 PPM <30 sec. +/- 1 PPM + 14 to 113 -10 to 45 20 – 95%
(1) Optional ranges available * = Non-Condensing (2) Response time to 90% full signal value for applied concentration
Specifications common to all IT Toxic Gas Sensor Modules Sensor type: Electrochemical Performance
Range: Default range as above
User selectable alternative ranges)
Sensor Life: Typically >2 years
Output:
Display: Fixed and Scrolling LED Signal Outputs: Sentry digital bus Analog 4-20 mA 3-wire Non-Isolated 4-wire Isolated Serial RS-485 Modbus RTU Relay : Optional
Options:
Relays: 5 amp Alarm, Warning (0.25 amp Trouble) 5A@ 250 VAC, 5A@ 30VDC (Alarm, Warning) Board includes auxiliary connection for Sentry
multiplexing
HART: Termination board includes HART, Modbus RS-
485, 4-20mA, Digital Input, 2A Relay output, No Sentry Bus
Power:
Power consumption: 2 watts maximum
Construction:
Dimensions: (HxWxD) (differs for 5100-25-IT & 5100-26-IT) (A1 & A2) 7.9 x 5.7 x 3.9 in. (20.1 x 14.5 x 9.9 cm) (S1 & S2) 7.6 x 4.4 x 4.9 in. (19.3 x 11.2 x 12.4 cm) Weight: (A1 & A2) 3.4 lb. (1.5 Kg) (S1 & S2) 7.2 lb. (3.3 Kg) Housing: Epoxy-coated, die-cast, copper-free Aluminum or
316 Stainless Steel Rating: Explosion proof, Class 1, Div. I, Groups B, C, D Group IIB + H2 IP66, IP65, NEMA 4X Warranty: 2 years Approvals: FM, CSA for enclosure in hazardous locations
FM Performance Approval (5100-05-IT) SIL-2 Certified (5100-04-IT, 5100-05-IT, 5100-06-IT) ATEX Certified II 2 G Ex d IIB+H2 T6 Gb Ta = -20
o
C to +50oC (5100-05-IT) IECEx Certified (5100-05-IT) CE Mark (5100-05-IT) ABS (5100-05-IT) CQST Certified for China (5100 -03, -04, & -05 -IT) CCOE/PESO Certified for India
Specifications subject to change without notice
Input voltage: 24 VDC nominal: 10-30VDC Remote Sensor Option: Distance:
5100-03-IT 10 feet 5100-04-IT 15 feet 5100-05-IT 15 feet
Operating Range
o
F
o
C RH*
Ordering Information:
Model Gas Enclosure
Output
5100 - XX - IT - XX - XX - XX - X - X - X
Relay/Connection
- 03 = O
- IT Series - A1 = AL ¾” NPT - 01 = No Relays (std) - 00 = Std. - 0 = Standard - 0 = None - 0 = Standard
2
- 04 = CO - A2 = AL M20 x 1.5 - 02 = Relays Option - 1 = Conformal - 1 = Remote - C = ATEX
- 05 = H
- 06 = Cl
- 08 = ClO
- 10 = SO
- 12 = NO
S - S1 = SS ¾” NPT - 05 = HART Option Sensor Sensor (5100-05-IT only)
2
2
2
2
2
- S2 = SS M20 x 1.5
Manufactured by
- 21 = HCl
- 25 = NH
3
- 26 = HF Accessories: 5311-00 Rainshield 5311-02 Rainshield with calibration port Calibration Accessories: 1250-01 Gas Sensor Calibration Kit, Type A (CO, H 1250-02 Gas Sensor Calibration Kit, Type B (SO 1250-03 Gas Sensor Calibration Kit, Type C (Cl
S) 1260-10 Gas Cylinder, SO2, 50 PPM, (Type B) 74 Liters
2
, NO2) 1260-12 Gas Cylinder, NO2, 10 PPM, (Type B) 74 Liters
2
, ClO2) 1260-13 Gas Cylinder, CO, 1000 PPM, (Type A) 105 Liters
2
1260-00 Gas Cylinder, Air, (Type A) 105 Liters 1260-21 Gas Cylinder, HCl, 5 PPM, (Type X) 581 Liters 1260-04 Gas Cylinder, CO, 100 PPM, (Type A) 105 Liters 5360-00 Calibration Head, Standard 1260-05 Gas Cylinder, H 1260-06 Gas Cylinder, Cl
S in N2, 25 PPM, (Type A) 57 Liters 9210-00 Calibrator, Permeation Type
2
, 5 PPM, (Type C) 104 Liters 9211-09 Permeation Tube, Ammonia, NH
2
Sensor Protection
Remote Option ATEX
3
Distributed by Aerionics, Inc. Sioux Falls, SD – Phone: 1-877-367-7891 – Email: info@aerionicsinc.com – www.macurco.com
Loading...