Macromatic THR-3 Series Data Sheet

PROGRAMMABLE
MULTI-FUNCTION | MULTI-TIME RANGE | MULTI-VOLTAGE
Relay Output | THR-3 Series
Application Data
Voltage Tolerance:
AC Operation: +10/-15% of nominal at 50/60 Hz DC Operation: +10/-15% of nominal
Load (Burden): Maximum of 2 VA for all voltages
Setting Accuracy:
Maximum Setting (Adjustable): +5%, -0% Minimum Setting (Adjustable): +0%, -50%
Repeat Accuracy (constant voltage and temperature): +0.1% or + 0.04 seconds, whichever is greater
Reset Time:
Triggered with Input Voltage: 100ms Triggered with Control Switch: 40ms
Start-up Time (Time from when power is applied until unit is timing):
0.05 Seconds
Maintain Function Time (Time unit continues to operate after power is removed): 0.01 Seconds
Units Triggered by a Control Switch:
Minimum required trigger switch closure time is 50ms.
Dimensions
Temperature: Operating: -28o to 65oC (-18o to 149oF) Storage: -40
Output Contacts:
10A @ 240VAC / 7A @ 28VDC SPDT, ¼hp @ 120VAC (N.O.)
Life:
Mechanical: 10,000,000 operations Full Load: 100,000 operations
Compatibility:
Using a solid state switch to initiate the time sequence is acceptable.
Mounting:
Surface with one #8 or #10 screw and a maximum tightening torque of 15 in-lbs.
Termination:
0.25” male quick-connect terminals
Approvals:
File #E109466
o
to 85oC (-40o to 185oF)
time delay relays | encapsulated
All Dimensions in
Inches (Millimeters)
11