current sensing relays | plug-in
Monitors AC currents for
overcurrent conditions
Three separate current
monitoring ranges covering
0.1 - 10 amperes
External CT can be used to
extend ranges
Adjustable Pick-up and Drop-
out Settings
Adjustable time delay of 0.1-10
seconds on pick-up
LED indicates output relay
status
Uses industry-standard 8 pin
octal socket
10A SPDT output contacts
with appropriate socket
AC OVERCURRENT
COKP Series
Current sensing relays can be used in several applications where protection of sen­sitive or expensive equipment against over or under current conditions is required, such as detecting (sensing) conveyor jam-up conditions, machine tool wear, no load conditions or monitoring status of heater or lamp loads.
The COKP Series is used to detect an overcurrent condition. The pick-up current setting is user-adjustable within one of three ranges as shown in the Product Selec­tion Table below. An external current transformer can be used to extend the range of these products. The drop-out setting is adjustable from 50-95% of the selected pick-up setting. The relay will energize when the monitored AC current is above the pick-up setting for a period longer than the adjustable time delay (t) of 0.1-10 seconds. This delay prevents nuisance tripping caused by inrush currents. It will de-energize when the monitored AC current is below the drop-out setting.
PICK-UP
SETTING
Adjustable
(Across
Monitored
Range)
DROP-OUT
SETTING
Adjustable
(From
50-95% of
Pick-Up)
INPUT
VOLTAGE
24V AC 0.1 - 1A
120V AC 0.1 - 1A
CURRENT
RANGE
MONITORED
0.5 - 5A
1 - 10A
0.5 - 5A
1 - 10A
CATALOG
NUMBER
COKP01A68 COKP05A68 COKP10A68
COKP01A62 COKP05A62 COKP10A62
WIRING/
SOCKET
8 Pin
70169-D
DIAGRAM 21
Sockets & Accessories available
4
| |
Application data
Dimensions
AC OVERCURRENT
COKP Series
Input Voltage Tolerance:
AC Operation: +10/-15% of nominal at 50/60 Hz.
Load (Burden):
Less than 5VA
Current Settings:
Pick-up: Adjustable throughout current range monitored Drop-out: Adjustable from 50-95% of pick-up setting
Response Times:
Pick-up: Adjustable 0.1-10 seconds Drop-out: Fixed 100ms
Output Contacts:
10A @ 240V AC / 7A @ 28V DC SPDT, 1/4 HP @ 120V AC (N.O.)
Life:
Mechanical: 10,000,000 operations Full Load: 100,000 operations
Temperature: Operating: -28o to 65oC (-18o to 149o F) Storage: -40o to 85oC (-40o to 185oF)
Indicator LED: Green when Input Voltage is applied; Red when Relay is energized
Reset: Automatic
Mounting:
Requires 8 pin octal socket (Macromatic 70169-D or equivalent)
Approvals:
File #E109466
File #E109466
current sensing relays | plug-in
All Dimensions in
Inches (Millimeters)