MacroAir AVD370-12 MacroAir AVD370 Installation Manual

Installation Manual
AVD 370 Fan
Table of Contents AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
1
Pre-Installation Checklist Introduction
Pre-Installation
Installation Overview Installing the Fan
Installing Guy Wires
Installing Fan Blades
Wiring the Fan
Mounting the Wall Controller
Fan Settings
Information
Pre-Installation Checklist . . . . . . . . . . . . . . . 2
Caution & Safety . . . . . . . . . . . . . . . . . . . . . . 3
Fan Clearance and Placement . . . . . . . . . . . 6
Rapid Mount Commercial. . . . . . . . . . . . . . . 7
Universal Mount . . . . . . . . . . . . . . . . . . . . . . 8
Fan Dimensions & Components,
I-Beam/Glulam Chart . . . . . . . . . . . . . . . . . . 9
Fuse Chart, Network Wiring Instructions . 10
Fan Components. . . . . . . . . . . . . . . . . . . . . 11
Mounts & Components . . . . . . . . . . . . . . . 12
Control Panel & Components . . . . . . . . . . 14
Tools Required . . . . . . . . . . . . . . . . . . . . . . 15
I-Beam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Glulam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
I-Beam Mounting. . . . . . . . . . . . . . . . . . . . . 18
Glulam Mounting. . . . . . . . . . . . . . . . . . . . . 21
Direct Mounting . . . . . . . . . . . . . . . . . . . . . 24
Unistrut Mounting. . . . . . . . . . . . . . . . . . . . 25
Mounting the Mounts . . . . . . . . . . . . . . . . .27
Mounting the Extension. . . . . . . . . . . . . . . .28
Motor & Safety Cable Routing . . . . . . . . . . 29
Mounting the Motor Unit. . . . . . . . . . . . . . 30
Motor Cable Connection . . . . . . . . . . . . . . 32
Safety Cable Installation . . . . . . . . . . . . . . . 33
Guy Wire Installation . . . . . . . . . . . . . . . . . 34
Guy Wire Tightening. . . . . . . . . . . . . . . . . . 35
Guy Wire Band Installation . . . . . . . . . . . . 36
Blade Assembly. . . . . . . . . . . . . . . . . . . . . . 37
Electrical & Safety Cable Installation . . . . 38
Control Panel Overview,
Step-Up Transformer Overview . . . . . . . . 39
Control Panel Schematics. . . . . . . . . . . . . . 40
Touchpad Remote User Interface . . . . . . . 42
Touchpad Remote Installation. . . . . . . . . . 43
Touchpad Remote Enclosure & Display . . 45
Touchpad Remote. . . . . . . . . . . . . . . . . . . . 46
Network Controller 30 . . . . . . . . . . . . . . . . 47
Mounting Bracket Hole Patterns. . . . . . . . 48
Maintenance. . . . . . . . . . . . . . . . . . . . . . . . 50
Troubleshooting . . . . . . . . . . . . . . . . . . . . . 51
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . 52
2 Pre-Installation Checklist AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
Literature (Pg. 3)
Order Verification. I have verified the order information. All components are accounted for.  Read. I have read this Installation Manual and all other instructions before installing this fan.
Power (Pg. 3-4) Power Requirements. I have verified the incoming power supply is sufficient for the fan.
Safety (Pg. 4-5)
Safety Familiarity. I am familiar with the safety components and features of the fan. I have verified the presence of a safety cable, and guy wires.
Airfoils (Pg. 5-7)
Height from Floor. I have verified the airfoils will be at least 10ft (3.05 m) above the floor.  Application Clearance. I have consulted the manual to determine that the airfoils will meet or
exceed the clearance requirements regarding obstructions, or other fans. Airfoil Reach. I have verified the airfoils will be mounted such that they are at least 3 feet
away from any area where someone can extend outward and reach them. High Winds. I have verified the fan will not be subjected to high winds from any outside
influences, such as large garage door openings or HVAC systems. Diffuser Interference. If diffusers are present, I will ensure that the fan is mounted at least
1.5X the diameter of the fan away from any source of airflow. Airfoil Compatibility. I have verified the Airfoils and other fan components are those that
shipped with the motor unit.
Installing Multiple Fans. I will not mix and match any hardware or blades.
Structure (Pg. 6-8)
Application Suitability. I have verified the application was approved by a structural engineer. I have checked the hanging weight and torque specs in the installation manual to ensure that the mounting structure can withstand the forces generated by the fan.
Structural Suitability. I have verified the building structure is suitable for this fan mounting. The fan will be mounted to an I-beam or Glulam or similar. I will not mount the fan to a single purlin, truss, or bar joist. I will consult a structural engineer for mounting not covered herein.
Mount Suitability. I have the appropriate mount for this application. I have verified in the installation manual that the mounting option provided is suitable for this application. I will consult a structural engineer for applications and mounting methods not covered herein.
Introduction AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
3
Caution and Safety
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
ATTENTION: Safety. READ AND SAVE THE ENTIRE MANUAL BEFORE OPERATING THE FAN.
Ensure that all safety procedures and instructions are followed during the installation, operation, and servicing of the fan. Failure to apply these safety practices could result in death or serious injury. If you do not understand the instructions, please call our technical department for guidance.
CAUTION: Non-Compliance. The fan installation should follow the recommendations
outlined in this manual. MacroAir is not responsible for any injury or damage to persons or property because of not complying with the recommendations outlined in the manual.
Electrical Guidelines
WARNING: Electrical Damage. Improper electrical installation can cause damage to the fan
and interfere with other electronic equipment. In addition to standard electrical safety considerations, please observe the following:
MacroAir Cables. The wiring from the control panel to the fan MUST be by MacroAir
supplied shielded cable.
Electrical Interference. Separate incoming power and motor control cables by a
minimum of six (6) inches.
Individual Fan Wiring. Run wiring for each fan separately.
Multiple Fans. Do not attempt to control multiple fans from one (1) control panel.
ALWAYS GROUND PROPERLY. Connect the supplied cable glands to each end of the
motor cable and tighten them securely at both the fan motor and control panel ends. Connect the ground bar in the control panel to ground at the main breaker and test.
Read. Please refer to the installation instructions for more information.
Introduction AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
4
Electrical Guidelines cont.
ATTENTION: Qualified Technicians. All fan controls should only be installed by qualified
technicians familiar with the requirements of the National Electrical Code (NEC) and local codes. Refer to appropriate portions of this manual for other important requirements. Failure to follow these guidelines will void the manufacturer’s warranty.
ATTENTION: Factory Configured. All electrical controls are configured at the factory and are
ready to use. No user adjustments are available. Follow the included wiring schematics and installation instructions when installing this device to ensure proper operation. Do not make any changes to any part of the motor control panel without first consulting MacroAir.
ATTENTION: Code Compliance. Installation is to be in accordance with the NEC, ANDSI/NFPA
70-1999 and local codes.
Hazard of Electrical Shock, Explosion or Arc Flash:
ATTENTION: Read. Read and understand this manual before installing or operating a fan unit.
Installation, adjustment, repair, and maintenance must be performed by qualified personnel.
ATTENTION: Code Compliance. The user is responsible for compliance with all international
and National Electrical Code requirements with respect to grounding of all equipment.
WARNING: Do Not Touch. Many of the parts of this unit operate at line voltage. DO NOT
TOUCH.
WARNING: Covers. Install all covers before applying power or starting and stopping the unit.
Installation and Service
WARNING: Damage. Do not operate or install any fans or fan accessories that appear to be
damaged.
WARNING: Death and Injury. Failure to follow this instruction can result in death, serious
injury, or equipment damage.
WARNING: Disconnect Power. If the fan does not operate properly using the procedures in
this manual. BE CERTAIN TO REMOVE ALL POWER TO THE UNIT and contact our technical department for further assistance.
CAUTION: Moving Parts. Keep all body parts clear of moving parts at all times. ATTENTION: Qualified Technicians. All electrical troubleshooting and repair must be done by
a qualified technician and meet all applicable codes.
Introduction AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
5
Key Safety Systems
ATTENTION: Safety. MacroAir fans are engineered with key safety features to prevent pieces
of the fan from falling in the unlikely event of a catastrophic failure. Used together, these systems and devices provide comprehensive protection to people, equipment, and property.
WARNING: Safety Cable and Guy Wires. Install safety cable on EVERY fan. Install guy wires
on every fan using a UMH mount, unless otherwise specified. Properly installing the guy wires will keep the fan stable in case of earthquake or in “outdoor” installations where high wind conditions may occur. The safety cable, if installed per MacroAir specifications, will prevent the fan from falling in the unlikely event that the mounting system should fail.
WARNING: Safety Cable. A MacroAir fan should never be run without a properly installed
safety cable, which is supplied with every fan along with all required hardware. You must install a safety cable for the warranty to be in effect.
ATTENTION: Mark the Floor to Alert Personnel. When mounting a fan in an area where
materials may be elevated into its path, MacroAir recommends marking or painting the floor with a large, crosshatched circle to alert personnel of the overhead location of fans.
Mounting Guidelines
WARNING: Weight Considerations. We recommend that a building structure be capable of
holding approximately twice the stated hanging weight of the fan. If there is some doubt of this, a professional contractor or architect should perform a thorough evaluation of the building prior to purchasing the fans. MacroAir provides guidelines for mounting fans; however, it is the sole responsibility of the building owner and installer to ensure the safety of the mounting system, that the building structure is sound, and that the installation complies with all federal, state, and local codes.
WARNING: Torque. The maximum torque (twisting force) that must be handled by the
mounting system, including the building structure, occurs at fan startup. For a 12-foot fan, maximum potential starting torque is 20 Ft-Lbs. When standard electrical controls are installed, the fan will never begin to approach this maximum because the standard variable-speed control system uses the soft-start fail, or when a fan is installed as a single-speed model without the variable speed control system (rare), full torque might be applied to the mounting system, so it is important that it be adequate to withstand 20 Ft-Lbs. torque.
ATTENTION: Check Federal, State, and Local Codes. Check all relevant codes to make sure
that all product certifications, product listings, and building regulations are met. Code compliance is the responsibility of the installer.
WARNING: Welding. DO NOT attach the fan or fan mounting components to the building
structure by welding that component to the structure. DO NOT cement the fan to the structure.
Introduction AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
6
Clearance Guidelines
ATTENTION: Sprinkler Systems and Fan Placement. In any installation where fire sprinklers
are in place, do not interfere with their correct operation. Fans should be located no less than 3 feet below a sprinkler and placed central to each sprinkler quadrant.
ATTENTION: Sprinkler Systems and Code Compliance. Prior to installing fans, review all
codes applicable to sprinkler systems and fans to ensure code compliance. Refer to the wiring diagrams packaged inside the control panel for proper installation. If further advice is needed, you may contact our support staff. However, it is your sole responsibility to see that the installation is completed to code and is correct.
General Information on Fan Placement and Spacing
ATTENTION: Strobe and Performance. If possible, avoid mounting fans directly below lights
or skylights to avoid any strobe effect caused by moving blades.
WARNING: Mezzanine Placement. If the building has a mezzanine, fans should be mounted
so a person cannot reach a fan in any way from the upper level/deck. Make certain that fans are positioned so that blade tips are at least 3 feet away from any area where a person may be able to extend outward to reach them.
Figure 1: Fan Clearance and Placement
ATTENTION: The minimum distance of a fan to a wall or similar obstruction should be no
less than 1.5 times the diameter of the fan. Reference Figure 1.
Introduction AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
7
General Information on Fan Placement and Spacing, cont.
Rapid Mount Commercial
Figure 2: Fan Clearance
Figure 3: Maximum Angle * Note: Greater than 5 drop requires Universal Mt with Guy Wires
Figure 4: Minimum Clearance (Horizontal/Vertical inches)
WARNING: FANS ARE NOT MEANT TO BE OPERATED IN WINDY CONDITIONS.
The goal of Figures 2 and 5 are to determine the proper extension length to maintain a minimum blade clearance of 3 feet for optimal performance. The extension lengths above are minimum recommendations only, based solely on roof pitch and fan diameter. Other factors must be evaluated when determining extension requirements.
ATTENTION: Minimum Height. MacroAir requires that the fan blades must be a minimum of
10 feet (3.05 meters) above the floor. Contact MacroAir for assistance with fan placement and extension selection.
Slope (in)
0
2/12
4/12
6/12
8/12
10/12
Roof Angle
0
9.5
18.4
26.6
33.7
39.8
Diameter
Recommended Total Drop (Mount to Airfoil) Length (ft)
6 feet
2 2 2 3 4 4 8 feet
2 2 3 3 4 5 10 feet
2 2 3 4 5
6*
12 feet
2 2 3 5 6*
8*
Airfoil / Drop Length (ft)
2 3 4 5 6 feet
7/7
7/7
8/8
9/8
8 feet
7/7
7/8
8/8
9/9
10 feet
7/8
7/8
8/9
9/10
12 feet
7/8
7/9
8/10
9/11
Introduction AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
8
General Information on Fan Placement and Spacing, cont.
Universal Mount (UMH)
Figure 5: Fan Clearance
Figure 6: Maximum Angle Note: Drop longer than 10ft not recommended
Figure 7: Minimum Clearance (Horizontal/Vertical inches)
ATTENTION: Minimum Height. MacroAir requires that the fan blades must be a minimum of
10 feet (3.05 meters) above the floor. Contact MacroAir for assistance with fan placement and extension selection.
Slope (in)
0
2/12
4/12
6/12
8/12
10/12
Roof Angle
0
9.5
18.4
26.6
33.7
39.8
Diameter
Recommended Total Drop (Mount to Airfoil) Length (ft)
6 feet
2 2 2 3 4 4 8 feet
2 2 3 3 4 5 10 feet
2 2 3 4 5 6 12 feet
2 2 3 5 6
8
Airfoil / Drop Length (ft)
2 3 4 5 6 7 8 9 10
6 feet
7/7
7/7
8/8
9/8
8/7
9/8
10/8
12/9
14/9
8 feet
7/7
7/8
8/8
9/9
8/8
9/8
10/9
12/10
14/10
10 feet
7/8
7/8
8/9
9/10
8/9
9/9
10/10
12/11
14/11
12 feet
7/8
7/9
8/10
9/11
8/10
9/10
10/11
12/12
14/13
Pre-Installation AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
9
Fan Dimensions
Dimensions listed above are applicable to all MacroAir AVD 370 fans.
I-Beam/Glulam Chart
I-Beam Min/Max
Glulam Min/Max
Minimum
Maximum
Minimum
Mid
Maximum
4.50
9.50
2.00
4.63
7.50
The Maximum Range dimension in these tables is determined by using the outside slots of the control panel. The Minimum Range dimension is determined by using the inside slots.
The Glulam mounting method (Referenced on pages 21-23) is recommended for Glulams or wood beams 5-1/8” or wider. For narrower beams, span across two or more beams using the Unistrut mounting method (Referenced on pages 25-26).
Pre-Installation AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
10
Max Amp Draw
Fuse Chart
MAX AMP DRAW / RECOMMENDED FUSE
VOLTAGE and PHASE
AVD 370 FAN
6FT
8FT
10FT
12FT
1.
100-120VAC / 1 PHASE
2.7A DRAW / FUSE N/A
2.
208-240VAC / 1 PHASE
1.4A DRAW / 2.5A FUSE
NOTE: 1. STEP-UP TRANSFORMER PANEL (REF PAGE 39).
2. FUSED DISCONNECT PANEL (REF PAGES 40-41).
Network Wiring Instructions
For clarification of approved networking principles and methods for installing MacroAir Fans, refer to the MacroAir control panel instructions included with your MacroAir Control Panel.
Pre-Installation AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
11
Fan Components
View of Assembled Fan
ATTENTION: Guy Wires are required when a Universal Mount is used to mount the fan.
Motor Unit
Images are not to scale
Pre-Installation AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
12
Mounts & Components
Rapid Commercial Mt (2-5 Drop) (shown w/mounting Bolt Kit) (4) Bolt, Soc HD Cap 1/4-20x1/2
UMH Mount (use w/2-10 Drop) (shown w/mounting Bolt Kit) (2) Guy Wire Bracket (4) Hex Bolts 3/8-16x3/4 (Used with UMH) (4) Washers, 3/8 Flat
Extension Tube (Aluminum used w/Rapid Commercial) (Steel used w/UMH Mount)
Extension Tube Bolt Kits (2) Hex Bolts 3/8-16x2-3/4 I-Beam Clamp & Bolt Kit (4) Washers, 3/8 (2) I-Beam Clamps (2) Nuts, 3/8 Nylon Lock (4) Hex Bolts 3/8-16x2 (8) Washers, 3/8 Flat Unistrut Mount Bolt Kit (optional) (4) Hex Nuts 3/8-16, Nylon Lock Hardware Required but Not Provided: Glulam Bolt Kit: (4) 3/8-16 x 1-1/2” Hex Bolts (4) Hex Bolts 3/8-16x1-1/4 (4) 3/8” Flat Washers (8) Washers, 3/8 Flat (4) 3/8” Unistrut Spring Nut (4) Hex Nuts 3/8-16, Nylon Lock Images are not to scale
Pre-Installation AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
13
Mounts & Components (cont.)
Glulam Brackets (optional) Safety Cable Kit Hardware Required but Not Provided: (1) Wire Rope 1/8 (4) 3/8-16 Grade 5 Hex Bolts (at least (2) Wire Rope Clamps 2-1/2” longer than Glulam) (8) 3/8” Flat Washers (4) 3/8” Nylon Lock Nuts
Guy Wire Assembly (4) Wire Rope, 19ft (A), 23ft (B*), 33ft (C*) Guy Wire Band Kit (4) Turn Buckles (1) Elastic Cord (4) 1/4” Quick Links (1) Cord Clip (8) Wire Rope Clamps * Kits B and C provided with longer drop lengths Images are not to scale
ATTENTION: Guy Wires are required when a UMH Mount is used to mount the fan.
Pre-Installation AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
14
Control Panel & Components
Control Panel (Mount using I-Beam Clamp or Glulam Brackets) Accepts Rapid Commercial or UMH Drop Mounts
CAT5E Stranded Shielded Cable
Digital Touchpad Remote
Blade Bolt Kit (16) Bolt, Soc Hd Cap #10-32x1-3/8 (1) Loctite 243
Images are not to scale
Pre-Installation AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
15
Tools Required
Note: A drill and drill bits will also be required when mounting brackets to Glulam
.
16 Installation Overview AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
I-Beam
1. Mount Fan Motor Unit using Rapid Commercial Mount or Universal Mount (UMH, not
shown) and drop extension onto the base of the control panel using hardware kit, combination wrench, and hex wrench.
2. The Control Panel must be secured to the I-Beam with I-Beam Clamps and hardware kit.
3. The Safety Cable exits top of Rapid Commercial Mount (or UMH) and needs to be fed around
I-Beam and secured with provided cable clamps.
Installation Overview AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
17
Glulam
1. The Safety Cable needs to be fed through a hole in the Glulam, preferably above the center
line of the Glulam.
2. The Control Panel must be secured to the Glulam with Glulam brackets and hardware kit. DO NOT discard the Glulam brackets and mount the control panel directly to the Glulam.
3. The Glulam brackets need to be through bolted to the Glulam as high as possible.
4. Mount Fan Motor Unit using Rapid Commercial Mount or Universal Mount (UMH, not
shown) and drop extension onto the base of the control panel using hardware kit, combination wrench, and/or Allen wrench.
18 Installing the Fan AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
I-Beam Mounting
1.) Assemble one side of I-Beam Mount with (1) Clamp, and Hardware.
I-Beam Clamps & I-Beam Bolt Kit (2) I-Beam Clamps (4) Hex Bolts 3/8-16x2
(8) Washers, 3/8Flat (4) Hex Nuts 3/8-16, Nylon Lock
Installing the Fan AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
19
I-Beam Mounting (cont.)
2.) Position the Control Panel under the I-Beam so that one side of the beam is between the clamp and the mount.
3.) Assemble other side of I-Beam Mount 4.) Hand tighten nuts to secure Clamp with (1) Clamp and Hardware. in place.
Installing the Fan AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
20
I-Beam Mounting (cont.)
5.) Center the Control Panel on the I-Beam.
6.) Using a 9/16combination wrench and a 9/16 socket and torque wrench tighten all hardware to 30 ft-lbs. [41 N-m]. Note: An extension may be required.
Installing the Fan AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
21
Glulam Mounting
This method is recommended for Glulams or wood beams 5-1/8” or wider. For narrower beams, span across two or more beams using the Unistrut mounting method. (Refer to page 24)
1. The Brackets can be located below the glulam if necessary but is not recommended.
Locate brackets even with bottom of glulam.
Installing the Fan AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
22
Glulam Mounting (cont.)
2. Drill maximum 1/2diameter clearance holes through the glulam for (4) 3/8-16 mounting
bolts (not provided by MacroAir) and (1) hole for the 3/16” diameter safety cable. The highest bolt hole should not be below the beam’s center line unless the glulam is too tall. The hole for the safety cable should be centered above the brackets (preferably above the center line of the glulam).
3. Secure the Glulam brackets to the Glulam via (4) 3/8-16 grade 5 bolts (long enough to go
through the entire beam with nylon lock nuts). Stack the Bolt, washer, washer, nut as shown above. Note: This hardware is not provided by MacroAir.
Installing the Fan AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
23
Glulam Mounting (cont.)
4. Using a 9/16combination wrench and 9/16” socket and torque wrench tighten all hardware to 30 ft-lbs.[41 N-m].
5. Mount the Control Panel to the glulam brackets using the Mount Bolt Kit which contains: (4) 3/8-16 x 2” Hex Bolts, (8) 3/8” Washers and (4) 3/8-16 Nylon Lock Nuts. Using a 9/16 combination wrench and a 9/16” socket and torque wrench tighten all hardware to 30 ft-lbs. [41 N-m].
Installing the Fan AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
24
Direct Mounting (Glulam or Wood Beam)
Glulam’s and wood beams must be at least 6 wide to use this mounting method.
1. A hole, all the way through the glulam,
needs to be drilled to accommodate 1/8Dia safety cable.
2. Position the mount so that the screws are as far away from the edge of the beam as possible.
3. Drill (4) pilot holes before installing screws.
4. Four (4) #10 x 2-1/2 Lag Screws are
provided if this method of mounting is indicated at time of fan purchase.
If mounting is to be into concrete, four (4) #10 x 1-3/4 concrete screws are provided.
Installing the Fan AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
25
Unistrut Mounting
This method is used to span components of a building structure. Attachment points to the building structure can vary greatly, so we recommend contacting Unistrut, so they can recommend the best method for attaching the Unistrut (www.unistrut.us).
1. Two (2) pieces of 1-5/8” x 1-5/8” 12-gauge Unistrut need to span the trusses. Distance apart
to be centered over the widest hole pattern in the Control Panel (see step 2). Maximum allowable distance between trusses is 8 feet. If the spanning distance is greater than 8 feet, please consult a Structural Engineer. Please refer to page 5 “Mounting Guidelines” for the maximum torque and weight values.
Hardware Required but Not Provided: (4) 3/8-16 x 1-1/2” Hex Bolts (4) 3/8” Flat Washer (4) 3/8” Unistrut Spring Nut (1) Loctite 243
Installing the Fan AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
26
Unistrut Mounting (cont.)
2. Attach the Control Panel in the most desired position between the trusses using hardware
indicated (not provided). Apply Loctite 243 to the 3/8-16 bolts prior to mounting. Unistrut clamps are not permitted in this mounting method.
3. Using a Torque wrench, tighten hardware to 30 ft-lbs (41 N-m).
NOTE: Mounting to C- and Z-purlins requires Unistrut span mounting. Mounting to trusses under three (3) inches in width requires two or more trusses to be linked with Unistrut. We recommend contacting Unistrut, so they can recommend the best method for attaching the Unistrut (www.unistrut.us).
Installing the Fan AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
27
Mounting the Mounts
Rapid Commercial Mount Universal (UMH) Mount
1. The Rapid Commercial Mount is 2. The UMH Mount is affixed to the bottom
affixed to the bottom of the mounted of the mounted Control Panel using the Control Panel using the provided Bolt provided Bolt Kit consisting of: Kit consisting of: (4) Hex Bolts 3/8-16x3/4L (4) Soc Hd Cap Bolts 1/4-20x1/5L (4) Washers, 3/8 Flat
3. Pass the motor power cable through the mounts as the mounts are installed. Continue the cable through the extension when installed (page 29) and through the motor when installed (page 31-32).
Installing the Fan AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
28
Mounting the Extension
1. Attach the extension to the bottom of the Rapid Commercial Mount (shown above) or the
Universal Mount UMH (shown below) and attach the top of the fan unit to the bottom of the extension with the provided hardware pack. Tighten hardware to 30 ft-lbs [41 N-m] using torque and combination wrenches.
Installing the Fan AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
29
Motor and Safety Cable Routing
1. The Safety Cable is fed up through the Drop Extension Tube and out through one of the
knock-outs on the Rapid Commercial mount, between the mount and the Control Panel or out the open UMH mount. The motor cable and the safety cable is to be routed through the mount and extension as shown above, after the mounts have been properly secured to the building.
2. When the motor is mounted to the
bottom of the extension, the motor cable and safety cable will be passed through the fan housing for connection inside the fan unit. This procedure is discussed in the following instructions.
Installing the Fan AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
30
Mounting the Motor Unit
1. Use a Phillips screwdriver to loosen the (3) #8-32
screws about the center of the cover. Do not remove the screws completely as they are captured on the cover with plastic lock washers.
2. Remove the bottom cover from the fan, ensure the
screws are still captured on the cover with the (3) nylon washers. Set the bottom cover to one side.
3. Remove the electrical cover and
the Safety Cable Retaining Bracket. Use a 9/64 Allen Wrench to remove the bracket. Momentarily set this hardware to one side.
4. Raise the fan and carefully guide
the motor shaft into the extension tube. Feed the safety cable and motor cable through the motor.
Installing the Fan AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
31
Mounting the Motor Unit, cont.
5. Bolt the fan motor shaft to the extension
tube. If Guy Wires are to be used (on UMH and steel extension), then fasten the Guy Wire mounting brackets at this location.
6. Be careful of the wires in the motor shaft
and extension tube.
7. Tighten the bolts to 30 ft-lbs [41 N-m]
using torque and combination wrenches.
8. The Safety Cable is fed up through the Drop Extension Tube and out through one of the
knock-outs on the Rapid Commercial mount, between the mount and the Control Panel or out the open UMH mount. Refer to the illustrations on page 29.
9. Attach the loop of the safety cable to the
retaining bracket, as shown. Pass the motor power cable through the hole provided in the bracket.
10. Reattach the retaining bracket to the
Motor with the hardware set aside in Step 3 (page 30). Use a 9/64 Allen Wrench.
Installing the Fan AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
32
Motor Cable Connection
1. The motor cable from the Control Panel is passed through the retaining bracket and
connected to the four-position terminal block.
2. Wiring to the terminal block:
Green wire chassis Gnd – motor control cable bare wire White wire – motor control cable black #1 wire Black wire – motor control cable black #2 wire Yellow wire – motor control cable black #3 wire
3. Replace the cover previously removed to access the
terminal block. Do not yet replace the MacroAir bottom cover as you still need access to install the blades.
Installing the Fan AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
33
Safety Cable Installation
I-Beam
1. Wrap 1/8 diameter safety cable from the mount,
around the I-beam multiple times.
2. Secure two (2) safety cable clamps around the wire.
Pull the cable taut and tighten both nuts using 3/8 combination wrench.
Glulam
1. Wrap 1/8 diameter safety cable from the mount,
through the hole drilled in the Glulam above brackets.
2. Secure two (2) safety cable clamps around the wire.
Pull the cable taut and tighten both nuts using 3/8 combination wrench.
34 Installing Guy Wires AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
Guy Wire Installation (use w/UMH Only)
Guy Wire Mounting Bracket
1. Attach the turnbuckle end of
the guy wires to the guy wire mounting brackets through the hole provided at each wing.
2. When laying out the locations
of the guy wire mounting points, attempt to maintain a 45-degree angle between the ceiling and the guy wires and 90-degree angle between each guy wire.
3. Avoid any sharp edges that may contact the guy wire. Guy wires need to be attached to the
building structure via 1/2” eye lags or bolts with the provided cable clamps. Eye Lags or bolts are not supplied by MacroAir.
WARNING: DO NOT wrap the guy wires around the building structure.
Installing Guy Wires AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
35
Guy Wire Tightening
4. Tighten down cable clamp nuts with a 11mm combination wrench (or socket wrench).
5. With the aid of a level placed against the drop extension, tighten the turnbuckles by hand in
a crisscross pattern while periodically checking to ensure that the fan is level.
6. Tighten the turnbuckles until the fan unit is stable in the level position.
WARNING: Make sure to not overtighten the turnbuckles.
7. Once all the guy wires are taut (stretched or pulled tight with no slack) and the fan unit is
stable and level, tighten the jam nuts on the turnbuckles with a 1/2” combination wrench.
WARNING: Do not use tools to tighten the turnbuckles; only use tools to tighten
the jam nuts.
Installing Guy Wires AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
36
Guy Wire Band Installation
1. Insert the elastic cord through the top eyelet of each of the 4 turnbuckles.
2. Pull one of the ends of the cord through one of the holes on the cable lock and then pull the
end into the groove to lock it. Use pliers to properly secure the cord in the groove of the cable lock.
3. Repeat the previous instruction for the second
end of the cord using the opposite hole and groove on the cable lock.
4. The safety cord should be pulled tight and
fastened as shown.
DO NOT EXCESSIVELY
STRETCH THE ELASTIC CORD.
37 Installing Fan Blades AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
Blade Assembly
1. Slide fan blade into a blade mounting block
until mounting holes line up. Insert three #10­32x1-3/8 Socket Head Cap Screws provided in Blade Bolt Kit. Tighten with 5/32 Allen wrench.
2. Install each blade in same manner.
3. Once all the blades are in place, reinstall the
MacroAir cover.
4. The three Screws to mount the cover should still
be attached to the cover with plastic lock washers.
38 Wiring the Fan AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
Electrical & Safety Cable Installation
WARNING: MOTOR CABLES AND INCOMING POWER MUST NEVER BE RUN IN THE SAME
CONDUIT. FAILURE TO INSTALL PER MACROAIR INSTRUCTIONS, INCLUDING WIRING, MAY BE HAZARDOUS, CAUSE PREMATURE FAILURE, AND VOID THE MANUFACTURE’S WARRANTY.
ATTENTION: Regulatory Notice, EMI (Electromagnetic Interference)
Electromagnetic Interference (EMI) is any signal or emission, radiated in free space or conducted along power or signal leads, that endangers the functioning of radio navigation or other safety services or seriously degrades, obstructs, or repeatedly interrupts a licensed radio communications service. Radio communications services include but are limited to AM/FM commercial broadcast, television, cellular services, radar, air-traffic control, pagers, and personal communications services (PCS). These licensed services, along with unintentional radiators such as digital devices, variable frequency drives (VFDs), and other equipment such as fans with VFDs, contribute to the electromagnetic environment.
Electromagnetic compatibility is the ability of items of electronic equipment to function properly together in the electronic environment. MacroAir Fans variable frequency drives, VFDs, are designed to be in compliance with regulatory agency limits for EMI. However, there is no
guarantee that interference will not occur in a particular installation. If MacroAir’s products
(fans) do cause interference with radio communications services, which can be determined by turning the fans off and on, please notify MacroAir technical support.
MacroAir Technologies’ products are designed, tested, and classified for their intended
electromagnetic environment. These electromagnetic environment classifications generally refer to the following harmonized definitions:
Class A is typically for business or industrial environment. Class B (MacroAir products are NOT designed for typical residential environments covered under
this classification).
CODE COMPLIANCE IS THE RESPONSIBILITY OF THE INSTALLER, AND ULTIMATELY, THE END USER. All wiring should conform to the National Electric Code (NEC) 2005, ANSI/NFPA 70-1999,
and all local codes. This fan control should only be installed by qualified technicians familiar with the requirements of the NEC and local codes.
Note: MacroAir Technologies has a policy of continuous product improvement and reserves the right to change design and specifications without notice.
If you have any questions, please contact MacroAir technical support.
Wiring the Fan AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
39
Control Panel Overview
Control Panels come pre-wired, as illustrated above.
1. Make sure the control wiring is CAT5e shielded, stranded or greater.
2. The Motor Cable and Cable Gland does come pre-installed.
3. Connect Stranded, Shielded CAT5e to RJ45 labeled “in” or controller for single touchpad
controller.
4. 25 feet of shielded power cable is provided exiting the control panel to be used to connect to
power source.
Step-Up Transformer Panel Overview
100-120VAC Option: A MacroAir Step-Up Transformer Panel is required for applications where the available line power is 100-120VAC. The Step-Up Transformer comes prewired as Illustrated here and is mounted using best industry methods.
A wiring diagram is shown below and a general wiring schematic for 100-120V is provided on page 40.
Wiring the Fan AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
40
Digital Control Panel Schematic (100-120V, 1PH)
Wiring the Fan AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
41
Digital Control Panel Schematic (208-240V, 1PH)
Mounting Wall Controller AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
42
Touchpad Remote User Interface
Buttons:
A – Forward / Reverse: Select fan rotational direction. B – Power Button: Turn the fan on or off (forward or reverse must be chosen to start the fan). C – Speed Up / Speed Down: Increase or decrease the speed of the fan. D – Speed Box: Real-time indication of fan speed. E – Navigation: Navigate to the next screen. F – Settings: Displays settings and information about the fan.
Mounting Wall Controller AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
43
Touchpad Remote Installation
Wall Mounting (Provided)
1. Gently remove the front bezel from the touch screen using a small flat tipped
screwdriver where the bezel notch meets the dismount tab located at the bottom of the touch screen.
2. Mount the base plate of the enclosure to the wall using the 4 provided wall anchors and
screws.
3. Snap the front of the enclosure to the base plate.
4. Plug in the pre-wired Stranded, Shielded CAT5e cable from the screen into the RJ45
coupler inside the enclosure.
5. Secure the touch screen to the enclosure using the 4 provided screws.
6. Lock the provided bezel into place via the plastic tabs.
7. Plug the provided Stranded, Shielded CAT5e cable from the fan into the RJ45 on the
outside of the enclosure.
Mounting Wall Controller AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
44
Touchpad Remote Installation (cont.)
Flush Mounting (Not Provided)
1. Gently remove the front bezel from the touch screen using a small flat tipped
screwdriver where the bezel notch meets the dismount tab located at the bottom of the touch screen.
2. Install the single gang electrical box (not provided).
3. Run the provided Stranded, Shielded CAT5e cable from the fan into the single gang
electrical box.
4. Plug the remote cable into the pre-wired Stranded, Shielded CAT5e cable from the
screen using the provided RJ45 coupler.
5. Secure the touch screen to the enclosure using the 2 provided screws.
6. Lock the provided bezel into place via the plastic tabs.
Mounting Wall Controller AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
45
Touchpad Remote LCD Display
Touchpad Remote Enclosure
46 Fan Settings AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
Touchpad Remote
1. Upon first power-up of the touchpad, the correct fan diameter will need to be selected.
2. After the blade size is selected, navigate to the next page using the arrow in the lower left to reach the Setting Blade Size page.
3. Once Setting Blade Size is done, press the lower left arrow to get to the Motor Type Screen. Then the lower left arrow again to get to the address screen. Change to the desired address and press the Reset button. If you do not need to change the address, press the arrow in the lower left until you are at the fan control screen.
4. If the fan stops operating unexpectedly, navigate to the fault code screen using the bottom right arrow and record any fault codes (if present). Click the reset button until the display reads ‘0’ or none. Then, attempt to run the fan again. If the fan is still not operating, navigate to the fault code screen via the navigation arrows at the bottom of the screen and document the code(s) displayed and call technical support at 866-668-3247. NOTE: Some faults can only be read from the VFD.
Home Screen Fault Code Screen
Fan Settings AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
47
Network Controller 30
1. Press the Settings button in the upper right corner.
2. Once on the Settings page, Press the Admin Login button and enter your credentials. The default Username and password are both "admin".
3. Once you are successfully logged in under Admin, go back to the fan control screen.
4. Once on the Fan screen, press the Configure button.
5. Once on the Configure screen, input the correct fan diameter and number of blades.
6. Press Done to return to the Fan Control Screen.
Note: For clarification of these and other procedures refer to the Manual included with your MacroAir Controller 30.
48 Information AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
Mounting Bracket Hole Patterns
Standard Mounting Pattern On Control Panel
Information AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
49
Mounting Bracket Hole Patterns, cont.
I-Beam Bracket
Glulam Bracket
Information AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
50
Maintenance
Guy Wire Check (if applicable): Checking a MacroAir fan’s guy wires for tension and inspecting
for frayed sections could mitigate a problem before it occurs. The guy wires should be under enough tension to prevent any movement in the motor unit or the extension tube. If the motor unit can be moved by pushing on it, the guy wires need to be tightened. Fan owners should confirm that the guy wires are not wrapped around any sharp edges. MacroAir recommends attaching guy wires to the building with eyebolts or eye lags. If they are not already installed with eye bolts or lags, we urge fan owners to install these to help keep the guy wires from fraying. If guy wires are installed with turnbuckles, jam nuts should periodically be checked to ensure tightness. If they are loose, the guy wire cables may need to be re-tensioned.
Blade Cleaning: Depending on the type of commercial application the MacroAir fan is in, there can be quite a bit of dust or other particulates that cling to the fan’s blades. While this may not affect fan performance, we recommend fan owners keep blades clean by having a maintenance person or skilled trade professional – who has experience using a lift – wipe the fan blades with a rag or sponge using hot water or mild cleaning solutions. Please do not use chlorine or any chemicals containing chlorine.
Safety Cable Check: Each MacroAir fan comes with a safety cable. Depending on the fan model, the safety cable either wraps around the building structure and the fan frame or comes out of the top of the fan and wraps around the building structure. The safety cable is an important part of the safety system and acts as a last resort should an earthquake, collision, or similar catastrophic event occur. As such, it is vital for fan owners to ensure that the safety cable is intact and properly secured.
Reverse Operation: The beauty of MacroAir HVLS fans is that they are built to run in forward and reverse mode. However, changing the direction of your fan can put initial stress on the fan if it has not been properly checked. It is a good idea to make sure guy wires, safety cables and all bolts and nuts are tight. Cleaning the fan before switching directions will prevent dust and other particles from falling off the fan airfoils when turning in the opposite direction.
Maintenance Plan: Things to look for include properly torqued fasteners, rust, cracked welds, unusual noise, hub migration/movement, guy wire loosing or movement.
Years 1-10: One inspection on lift per year. Year 11 and beyond: Annual inspections from a lift and seasonal inspections both before and
after the busy season from the ground.
NOTE: If there are issues or concern discovered during an inspection, please contact the service and technical support department at MacroAir for help.
CONTACT US: For installation assistance, application questions, technical sales support & any other inquiries, please contact us at (866) 668-3247.
Information AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
51
Troubleshooting
Please refer to the table below if you experience issues with the fan operation.
Symptoms
Possible Solution
The fan is not turning and the lights on the VFD are lit.
Flip disconnect switch to “OFF” for 30 seconds and then flip switch to “ON”. Ensure that the VFD is properly connected to the motor.
The fan is not turning and the lights on the VFD are NOT lit.
Confirm that there is power coming from the building.
The fan is spinning in reverse when forward is selected.
Confirm the motor is wired in the correct order per page #32.
The fan will rock and will not start.
Confirm that the correct fan diameter is set on the controller.
The fan is spinning too slow/fast.
The fan is shutting off at high speed.
The fan is operating noisily.
Confirm that there is nothing interfering with any moving parts. Confirm that the correct fan diameter is set on the controller.
The fan is wobbling.
Confirm that the fan is level, and the guy wires (if present) are properly installed and tightened. If the fan is installed on Unistrut, confirm with a structural engineer that the mounting is adequate for the fan weight and torque.
If your issue cannot be resolved using the table above, please contact MacroAir technical support at (866) 668-3247.
Information AVD 370 FAN
© 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370 INSTALLATION MANUAL 90-30071-00 Rev A-04 Date: 101521
52
Warranty
MacroAir warrants the Products listed in the table below will be free from defects in materials and workmanship under normal use and maintenance for the applicable Warranty Period. Other than the Warranty set forth in this document, no other written or oral warranties apply, and no employee, agent, dealer, or other person is authorized to give any other warranties on behalf of MacroAir.
START DATE OF WARRANTY COVERAGE
Warranty Period begins fifteen (15) days following shipment of the Product, or on the date the Product is installed (not to exceed sixty (60) days Customer receives the Product), whichever date is later. Customer should retain necessary documentation to verify the date of receipt and installation of the Product. Customer will be required to produce this documentation in order to obtain Warranty services from MacroAir. The Warranty specified herein applies only to Products purchased on or after April 15, 2021.
PRODUCTS AND SYSTEMS COVERED BY THIS WARRANTY AND APPLICABLE WARRANTY PERIODS:
Fan Type
Mechanical: Blades, Hub & Frame
Standard Electrical1: Motor,
Electrical Controls, Remote
Labor
AVDX
15 Years
10 Years
1 Year
AirVolution
15 Years
7 Years
1 Year
AirLegacy
15 Years
5 Years
1 Year
AVD3
10 Years
5 Years
1 Year
AVD 370
10 Years
5 Years
1 Year
WARRANTY COVERAGE:
Subject to the exclusions herein, the MacroAir Warranty covers any defects in workmanship or materials of the covered Products under normal operation and prescribed maintenance when those defects adversely affect the ability of the Product to operate properly.2 The Warranty only covers Products which have been installed in compliance with MacroAir's written installation instructions by a state-qualified or licensed electrical contractor and operated and maintained by the Customer in conformity with MacroAir's written instructions, and when the Product is purchased directly from MacroAir or a MacroAir Authorized Dealer.
This Warranty is subject to all provisions, conditions, limitations, and exclusions explained in this Warranty document.
*Scan QR code or visit macroairfans.com/warranty for full warranty information.
1 "Standard Electrical" means any common electrical component that is utilized across more than one fan line will assume the higher warranty period. 2 "Operate properly" applies only to mechanical, electrical, and structural systems of the Product.
794 South Allen Street San Bernardino, CA 92408 (866) 668-3247 Macroairfans.com