MacroAir AirVolution Specifications Sheet

Page 1
AirVolution
8 in / 203.2 mm
36 in / 914.4 mm
The MacroAir AirVolution uses a proven industrial
gearbox-driven power unit in combination with integrated network technology. Combine with one of our multi-fan network controllers, AirEffect temperature control, or AirLynk for Building Management Systems for advanced control. With a premium industrial gearmotor and advanced control platforms, you get more than fan, you get one of the most versatile cooling solutions available
STANDARD FEATURES
Integrated Gearmotor
Clearcoat anodized airfoil blades
Variable Frequency Drive – Forward, reverse, variable speed and capable of Building Automation Integration
(with AirLynk upgrade) and re alarm
Safety Components: safety cable, Universal Mount
with guy wires, blade retainer links
STEP 1: DIAMETERS
Item # Diameter Qty
MY08-0100-MA 8 ft Power Unit, 1.0 HP MY10-0100-MA 10 ft Power Unit, 1.0 HP MY12-0100-MA 12 ft Power Unit, 1.0 HP MY14-0100-MA 14 ft Power Unit, 1.0 HP MY16-0100-MA 16 ft Power Unit, 1.0 HP MY18-0100-MA 18 ft Power Unit, 1.0 HP MY20-0150-MA 20 ft Power Unit, 1.5 HP MY24-0200-MA 24 ft Power Unit, 2.0 HP
STEP 2: VOLTAGE
Item # Voltage Options Qty
2xx1-MA 208-240V Single Phase, 50/60 Hz 2xx3-MA 208-240V Three Phase, 50/60 Hz 4xx3-MA 480V Three Phase, 50/60 Hz
xx=horsepower
STEP 3: MOUNTING
Item # Mount Options Qty
60-90006-00 60-40041-00
AirVolution Universal Mount: I-beam Hardware Kit (Standard)
Glulam Hardware Kit (for Universal Mount)
STEP 4: CONTROLS
Item # Description Qty
30-90308-00 30-04006-00 30-04007-00 30-04030-00 30-10012-00 30-10011-00 30-90315-00 30-04030-02 10-04009-00
*Only compatible with Controller 30, pricing is per zone. Not compatible with Dual Control option.
Rev. Date 040218 © 2018 MacroAir Technologies Toll Free: 866 6 68 3247 Fax: 909 8 90 2313 ww w.macroairf ans.com 9
Local Override Remote (requires AirLynk-BacNet)
Dual Control Enabled Controller 30 (requires AirLynk-BacNet)
AirEffect (one per zone, up to 4 per Controller 30)*
© 2021 M acro Air Technolo gies Toll Free: 8 66 668 32 47 Fax: 9 09 89 0 2313 w ww.macr oair fans.com Rev. 210525
Digital Remote Assembly (Standard)
Controller 4
Controller 4 + Temperature Sensor
Controller 30
AirLynk - BacNet (per fan)
AirLynk - LonWorks (per fan)
Page 2
AirVolution
OPTIONAL: EXTENSIONS
Item # Length (ft/in) Length (m) Qty
51-80100-02 1 ft 0.30 m
51-80200-02 2 ft 0.61 m
51-80300-02 3 ft 0.91 m
51-80400-02 4 ft 1.22 m
51-80500-02 5 ft 1.52 m
51-80600-02 6 ft 1.82 m
51-80700-02 7 ft 2.13 m
51-80800-02 8 ft 2.44 m
51-80900-02 9 ft 2.74 m
(51-8ftin-02) Customization fee
ft = length in feet (i.e. 04 for 4 feet, 10 for 10 feet) in = length in inches (i.e. 05 for 5 inches, 10 for 10 inches)
To order Extension greater than 10 ft, please call MacroAir.
AirVolution EXTENSIONS are an
additional drop tube attached to the top of the frame. Without an
Extension, the total drop for an AirVolution fan is 3 ft (fan, frame,
and mount)
AirVolution fans can only be
connected with a single-piece of custom length extension.
Do you have a custom color in mind? Custom powder coating is available for all our blades, mounts and drop lengths.
OPTIONAL: POWDER COATING
Item # Diameter Estimated Lead Time Qty
60-10008-02 8 ft / 2.44 m 15 business days 60-10010-02 10 ft / 3.05 m 15 business days 60-10012-02 12 ft / 3.66 m 15 business days 60-10014-02 14 ft / 4.27 m 15 business days 60-10016-02 16 ft / 4.88 m 15 business days 60-10018-02 18 ft / 5.49 m 15 business days 60-10020-02 20 ft / 6.07 m 15 business days 60-10024-02 24 ft / 7.32 m 15 business days
Special Finishes
Mounting Hardware & Frame
Extension (when applicable)
All Diameters 15 business days
All Diameters 15 business days
For powder coating colors, please refer to Appendix A.
ADDITIONAL OPTIONS
Item # Description Qty
-FD
-EX
*Only available for 8ft-18ft
Explosion Proof Motor* -1.0 HP (Separate Motor and Gearbox)
Rev. Date 040218 © 2018 MacroAir Technologies Toll Free: 866 6 68 3247 Fax: 909 8 90 2313 ww w.macroairf ans.com 10
Food-Grade / Stainless Steel - 1.0 HP*
© 2021 M acro Air Technolo gies Toll Free: 8 66 668 32 47 Fax: 9 09 89 0 2313 w ww.macr oair fans.com Rev. 210525
Page 3
AirVolution
BASIC SPECIFICATIONS
AIRFOIL DIAMETER
Airfoil Style 7.375’’ Extruded Anodized Aluminum Airfoil
Number of Airfoils 6
8ft 10ft 12ft 14ft 16ft 18ft 20ft 24ft
PERFORMANCE
Max Speed 202 RPM 162 RPM 129 RPM 103 RPM 84 RPM 70 RPM 70 RPM 62 RPM
Recommended Spacing*
Max Affected Area
Sound Level dBA at Max Speed** 58 58 58 58 58 58 61 61
50 ft
[15.2 m]
3,600 ft [336 m2]
2
60 ft
[18.3 m]
6,000 ft [557 m2]
65 ft
[19.8 m]
2
8,000 ft [743 m2]
2
70 ft
[21.3 m]
10,000 ft
[929 m2]
2
85 ft
[25.9 m]
12,000 ft
[1,115 m2]
2
90 ft
[27.4 m]
14,000 ft
[1,301 m2]
2
100 ft
[30.5 m]
18,000 ft
[1,673 m2]
2
110 ft
[33.5 m]
20,000 ft
[1,858 m2]
HANGING REQUIREMENTS
Hanging Weight
Max Torque
Max Thrust in Reverse
171 lbs
[77.56 kg]
18 ft-lb
[24 Nm]
4 lbs
[1.8 kg]
178 lbs
[80.74 kg]
24 ft-lb
[33 Nm]
6 lbs
[2.7 kg]
189 lbs
[85.73 kg]
31 ft-lb
[42 Nm]
9 lbs
[4.1 kg]
195 lbs
[88.45 kg]
43 ft-lb
[58 Nm]
14 lbs
[6.4 kg]
202 lbs
[91.63 kg]
40 ft-lb
[54 Nm]
15 lbs
[6.8 kg]
208 lbs
[94.35 kg]
58 ft-lb
[79 Nm]
21 lbs
[9.5 kg]
217 lbs
[98.43 kg]
88 ft-lb
{119 Nm]
31 lbs
[14.1 kg]
270 lbs
[122.5 kg]
126 ft-lb
[171 Nm]
44 lbs
[20 kg]
MOTOR AND DRIVE TRAIN
Motor Type AC induction Motor with a sealed 2-stage helical gear box
Equivalent Horsepower Rating 1.0 HP (8-18ft) / 1.5 HP (20ft) / 2.0 HP (24ft)
Operating Temp Range 16°F [-10C°] - 104 F° [40C°]
MAX AMP DRAW
208-240V Single Phase
208-240V Three Phase
480V Three Phase
20.2A
10.8A
4.3A
POWER AND CONTROLS
2
Power Source Single Phase 208-240 VAC 50/60 Hz / Three Phase 208-240 VAC 50/60 Hz / Three Phase 480 VAC 50/60 Hz
Control Options Digital Touchpad, MacroAir Controller 4, Controller 30, AirLynk - BacNet / LonWorks
INSTALLATION
Mounting Hardware Universal Mount Hardware
Extension Optional extensions are available in 1ft increments; all drop lengths require guy wires
RATINGS AND COMPLIANCE
Fire and Sprinkler NFPA Compliant
Wash Down Duty Rating*** IP55
Certications UL 507
*For spacing between fan units based on the dimensions of a specic space please refer to https://macroairfans.com/airviz.
**Sound testing taken with the sensor 5 ft above the ground and 20 ft from the center of the fan at 20 ft high.
***Applicable to the fan unit only, does not include controller and control panel.
Rev. Date 040218 © 2018 MacroAir Technologies Toll Free: 866 6 68 3247 Fax: 909 8 90 2313 ww w.macroairf ans.com 11
© 2021 M acro Air Technolo gies Toll Free: 8 66 668 32 47 Fax: 9 09 89 0 2313 w ww.macr oair fans.com Rev. 210525
Page 4
MacroAir Controllers - Digital Remote
Standard on all MacroAir fan models (Except AirLegacy)
• Simple and intuitive control
Easy ground-level troubleshooting and diagnostics
Features Digital Touchpad Remote
Item # 30-90308-00
# Fans Controlled 1 fan
Display 2.8 TFT
Resolution 240x320x16 pixels
Backlight life time 20,000 hours
Backlight brightness 160 cd/m2
Shock IEC 60068-2-27
Vibration IEC 60068-2-6
Rating (front) IP 40 / NEMA 1
Weight (incl. enclosure) 375 g
Communication Protocol RS 485
Power Supply 24V from fan
Size (incl. enclosure) 91.2 x 135.5 x42.0
Operating Temperature -4
Storage Temperature -22
o
to 158oF / -20o to +70oC
o
to 176oF / -30o to +80oC
Note: Only one type of controller can be used when selecting Controller 4, Digital Remote Assembly or Analog Remote Assembly. AirLynk (BacNet) can be used as a stand alone, or paired with a Dual Control Enabled Controller 30 (see Dual Control page) or with Local Override Remotes for some fan models (see Local Override page)
Rev. Date 040218 © 2018 MacroAir Technologies Toll Free: 866 6 68 3247 Fax: 909 8 90 2313 ww w.macroairf ans.com 27
© 2021 M acro Air Technolo gies Toll Free: 8 66 668 32 47 Fax: 9 09 89 0 2313 w ww.macr oair fans.com Rev. 210525
Page 5
MacroAir Controllers - Controller 4
Available upgrade for all MacroAir fan models (Except
AirLegacy)
• Control up to 4 fans from a single point
Control fans individually, independent of speed &
direction
• Simple and intuitive control
Temperature sensor (optional upgrade) starts and stops
the fan(s)
Features Controller 4 Controller 4 with temperature sensor
Item # 30-04006-00 30-04007-00
# Fans Controlled Up to 4 fans, individually
Display 2.8 TFT
Resolution 240x320x16 pixels
Backlight life time 20,000 hours
Backlight brightness 160 cd/m2
Shock IEC 60068-2-27
Vibration IEC 60068-2-6
Rating (front) IP 40 / NEMA 1
Weight (incl. enclosure) 375 g
Communication Protocol RS 485
Power Supply 24V from fan
Size (incl. enclosure) 91.2 x 135.5 x42.0
Operating Temperature -4
Storage Temperature -22
o
to 158oF / -20o to +70oC
o
to 176oF / -30o to +80oC
Note: Only one type of controller can be used when selecting Controller 4, Digital Remote Assembly or Analog Remote Assembly. AirLynk (BacNet) can be used as a stand alone, or paired with a Dual Control Enabled Controller 30 (see Dual Control page) or with Local Override Remotes for some fan models (see Local Override page)
Rev. Date 040218 © 2018 MacroAir Technologies Toll Free: 866 6 68 3247 Fax: 909 8 90 2313 ww w.macroairf ans.com 28
© 2021 M acro Air Technolo gies Toll Free: 8 66 668 32 47 Fax: 9 09 89 0 2313 w ww.macr oair fans.com Rev. 210525
Page 6
MacroAir Controllers - Controller 30
STANDARD FEATURES
Available upgrade for all MacroAir fan models
(except AirLegacy)
Provides a single point for individual or group fan control
Enables run time, scheduling, grouping, and fan naming
Secure remote login to controller via smart device or computer
Optional auto mode available with AirEffect
Password protection capabilities for scheduling,
naming, and temperature/humidity (with upgrade to AirEffect)
Features Controller 30
Item # 30-04030-00
# Fans Controlled 30 fans
Display 10.1” (16:9), TFT-LCD with LED backlight
Resolution 1024x600 pixels
Backlight life time 50000 hours
Backlight brightness 500 cd/m2
Shock 15g, half-sine, 11ms according to IEC60068-2-27
Vibration 1g, according to IEC 60068-2-6, Test Fc
Sealing front IP65, NEMA 4X/ 12 and UL Type 4X/ 12
Sealing back (excl. enclosure) IP20
Weight (incl. enclosure) 10 lb / 4.5 kg
Communication Protocol MODBUS RS485
Ethernet Port 2x100 Mbit
USB Port 2
Power Supply 110-240 V
Size (incl. enclosure) 10.7 x 13.0 x 3.7 in (W x H x D) / 272 x 330 x 84 mm (W x H x D)
Operating Temperature 14
Storage Temperature -4
Languages English, Spanish, French, Malay
o
to 140oF / -10o to +60oC
o
to 158oF / -20o to +70oC
Note: Only one type of controller can be used when selecting Controller 4, Digital Remote Assembly or Analog Remote Assembly. AirLynk (BacNet) can be used as a stand alone, or paired with a Dual Control Enabled Controller 30 (see Dual Control page) or with Local Override Remotes for some fan models (see Local Override page)
Rev. Date 040218 © 2018 MacroAir Technologies Toll Free: 866 6 68 3247 Fax: 909 8 90 2313 ww w.macroairf ans.com 29
© 2021 M acro Air Technolo gies Toll Free: 8 66 668 32 47 Fax: 9 09 89 0 2313 w ww.macr oair fans.com Rev. 210525
Page 7
AirEffect Temperature Control
STANDARD FEATURES
AirEffect (only available with Controller 30) is an optional control system that senses and automatically maintains a desired room
temperature. AirEffect gages the heat index by measuring the temperature and humidity at the ceiling and oor. To achieve the desired temperature, AirEffect takes the heat index and calculates the fan’s ideal operating speed and direction and runs the fans accordingly. Simply setup AirEffect to the desired temperature range and enjoy a consistently comfortable environment.
Senses and maintains desired room temperature
Measurers temperature and humidity at two points (ceiling & oor)
Calculates heat index through temperature and humidity calculations
Runs fans in reverse or forward direction in response to heat index
Compatible with all fans (except AirLegacy)
Independent, external sensors allow the controllers to be mounted in a different room than the fans and sensors
Features AirEffect (up to 4 zones)
Item # 30-04009-00
Number of Sensors 2 (1 oor & 1 ceiling)
Measured temperatures -40 through +125 °C (±2 to ±4 %)
Measured humidity 0 through 100% RH (±2 to ±4 %)
Communication Protocol MODBUS RS485
*Controller not included
Rev. Date 040218 © 2018 MacroAir Technologies Toll Free: 866 6 68 3247 Fax: 909 8 90 2313 ww w.macroairf ans.com 30
© 2021 M acro Air Technolo gies Toll Free: 8 66 668 32 47 Fax: 9 09 89 0 2313 w ww.macr oair fans.com Rev. 210525
Page 8
AirLynk BMS Integration
AirLynk BMS Integration
Gives the ability to control your fans through BACnet® (MS/TP or IP) and LonWorks®.
BACnet and LonWorks are both protocols used to automate or manage buildings systems (commonly called a BMS or BAS). Our fans use MODBUS to communicate and the correct use of AirLynk, MacroAir’s interface, will allow the integration of our fans into a BMS/BAS. A BMS/BAS enables you to run the fans in conjunction with your HVAC system to help save energy costs.
Our proven solution is AirLynk, an external, high-performance building automation multi-protocol interface that is pre congured to communicate between any MacroAir fan and various building automation protocols including: BACnet®MS/TP, BACnet/IP, Modbus TCP/IP, and LonWorks®.
Successful integration of any MacroAir fan with a BMS/BAS is dependent upon following these guidelines:
Identify the BMS and its protocol before the purchase order is placed. This allows the fans to be pre programmed, dramatically
reducing installation errors and integration time.
Strictly adhere to the included installation manual to eliminate issues that will occur from wrong types of wire, improper wire terminations or wire routing.
We highly recommend engaging our Controls Engineers to visit the site for fan start-up to ensure a smooth and successful
integration. Our experience has found that many installers are unfamiliar with the subtle but critical differences between BMS systems, interfaces, fan models, connection methods and best practices. For a nominal fee plus travel expenses, one of our Controls Engineers can be on site to ensure a smooth and successful start-up. For more information about this service, please
inquire with our Technical Services Department.
To Order BMS enabled fans and AirLynk please do the following:
Identify the BMS network
Discuss your network with MacroAir’s Control Engineers
Order one AirLynk to connect up to 30 fans
Item # Description
30-10012-00 AirLynk - BACnet, (Works on all Fan Lines, except AirLegacy), Up to 30 Fans per AirLynk
30-10011-00 AirLynk - LonWorks, (Works on all Fan Lines, except AirLegacy), Up to 30 Fans per AirLynk
30-90315-00 Local Override Remote (each fan) for BMS (Works on all Fan Lines, except AirLegacy and AVD 370)
30-04030-02 Dual Control Enabled Controller 30 (Works on all Fan Lines, except AirLegacy) Up to 30 Fans per AirLynk
10-80632-00 Repeater (required for some older model fans; contact your sales rep for details)
Note: Only one type of controller can be used when selecting Controller 4, Digital Remote Assembly or Analog Remote Assembly. AirLynk (BacNet) can be used as a stand alone, or paired with a Dual Control Enabled Controller 30 (see Dual Control page) or with Local Override Remotes for some fan models (see Local Override page)
Rev. Date 040218 © 2018 MacroAir Technologies Toll Free: 866 6 68 3247 Fax: 909 8 90 2313 ww w.macroairf ans.com 31
© 2021 M acro Air Technolo gies Toll Free: 8 66 668 32 47 Fax: 9 09 89 0 2313 w ww.macr oair fans.com Rev. 210525
Page 9
Local Override Remote for BMS Integration
Works with AVDX and AirVolution fans when paired with AirLynk
Allows local user to control speed and direction when in FWD or
REV Mode
Allows Building Management System to control speed and
direction when in Auto Mode
Takes last known command from BMS when returned to Auto
Mode
• Simple and intuitive control
3-Year-Warranty
Features Local Override for BMS
Item # 30-90315-00
# Fans Controlled 1 to 1 fan control by Local Override Remote, up to 30 by BMS/AirLynk
Rating NEMA/EEMAC Type 1
Communication Protocol 0-10V Wall Mounted Override Remote, Modbus/BACnet AirLynk
Operating Temperature -4
o
to 140oF / -20o to +60oC
Rev. Date 040218 © 2018 MacroAir Technologies Toll Free: 866 6 68 3247 Fax: 909 8 90 2313 ww w.macroairf ans.com 32
© 2021 M acro Air Technolo gies Toll Free: 8 66 668 32 47 Fax: 9 09 89 0 2313 w ww.macr oair fans.com Rev. 210525
Page 10
Dual Control for BMS Integration
STANDARD FEATURES
Seemless integration of a building management system and local fan network
Fans take last known command, be it from the BMS, the Dual Control enabled Network Controller 30 screen(s), or VNC enabled smart
devices
Provides a single point of local control of up to 30 fans
Enables grouping and fan naming
Password protection capabilities for operation, naming, and grouping
Requires AirLynk (BacNet) and Dual Control
Enabled Controller 30*
*AirEffect is not compatible with Dual Control. Temperature monitoring by BMS can regulate fan operation.
Rev. Date 040218 © 2018 MacroAir Technologies Toll Free: 866 6 68 3247 Fax: 909 8 90 2313 ww w.macroairf ans.com 3 3
© 2021 M acro Air Technolo gies Toll Free: 8 66 668 32 47 Fax: 9 09 89 0 2313 w ww.macr oair fans.com Rev. 210525
Page 11
Fan Placement & Clearance
Fan Placement & Clearance
B
A
Fluorescent Light
Light
Ambient light
Light
General Notes:
Dimension "A": The smaller the distance between the light and the blade, the higher concentration and frequency of shuttering. So the greater distance "A" is from the fan blade, the less the shuttering effect.
Dimension "B": The closer the light is located to the center of the fan, the higher the frequency of shuttering.
Ambient light: Another variable increasing the shuttering effect is the amount of ambient light available. The more lights, the less the effect. As shown, the more overlapping patterns the less shuttering/strobing. The type of light can also influence the effect. For example, a domed light is more sensitive than a fluorescent tube.
Summary: Variables that affect strobing are (1) blade to light height, (2) the fan center to light dimension, and (3) the amount of ambient light within the space. To minimize the
Summary: Variables that affect strobing are (1) blade to light height, (2) the fan center to light dimension, and (3) the amount of ambient light within the space. To minimize the possible negative effects of strobing, follow all MacroAir installation instructions including clearance requirements.
LIGHT SHUTTERING/STROBING WITH HVLS FAN SYSTEMS
HVAC Diffuser
with airflow UNDER fan
at least 3 x diameter of the fans apart
spacing between fans
space from
wall
space from diffuser
at least 1.5 x diameter away from
intake/discharge
HVAC Diffuser
with airflow
ABOVE fan
at least 1.5 x
diameter away
from the wall
space from diffuser
at least 2 x diameter away from intake/discharge
Rev. Date 040218 © 2018 MacroAir Technologies Toll Free: 866 6 68 3247 Fax: 909 8 90 2313 ww w.macroairf ans.com 37
© 2021 M acro Air Technolo gies Toll Free: 8 66 668 32 47 Fax: 9 09 89 0 2313 w ww.macr oair fans.com Rev. 210525
Loading...