Digital Attenuator, 31.0 dB, 5-Bit,
TTL Driver, DC-6.0 GHz
V 5.00
AT90-0001
Features
n Attenuation: 1.0 dB Steps to 31 dB
n High Accuracy to 6 GHz
n Small Footprint, JEDEC Package
n Integral TTL driver
n 50 ohm impedance
n Test boards are available
n Tape and Reel Packaging Available
Description
M/A-COM’s AT90-0001 is a GaAs FET 5-bit digital attenuator with an integral TTL driver. Step size is 1.0 dB
providing 31 dB total attenuation range. This device is in a
32 lead FQFP-N surface mount package. Due to superior
grounding techniques this digital attenuator offers superior
performance to 6 GHz. The AT90-0001 is ideally suited for
use where accuracy, fast speed, very low power consumption and low costs are required.
CSP-1
Electrical Specifications TA = +25°C
Parameter Test Conditions Frequency Units Min Typical Max
Insertion Loss — DC - 2.0 GHz
Attenuation
Accuracy
VSWR Full Range DC - 2.0 GHz
1 dB Compression —
Input IP2 Two tone inputs to +5 dBm 50 MHz
Input IP3
Switching Speed 50% Cntl to 90%/10% RF
Logic "0"
Logic "1"
Vcc
-Vee
Icc Vcc min to max, Logic “0” or 1” — mA — 0.2 6
-Iee Vee min to max, Logic “0” or 1” — mA — -0.2 -1
1 to 24 dB Bits
25 to 31 dB Bits
—
Two-tone inputs up to +5 dBm 50 MHz
—
—
10% to 90% or 90% to 10%
Sink Current is 20 µA Max.
Source Current is 20 µA Max.
DC - 4.0 GHz
DC - 6.0 GHz
DC - 6.0 GHz
DC - 6.0 GHz
DC - 6.0 GHz
50 MHz
0.5 - 6.0 GHz
0.5 - 6.0 GHz
0.5-6.0 GHz
—
—
—
—
—
—
dB
dB
dB
dB
dB
Ratio
Ratio
dBm
dBm
dBm
dBm
dB
dB
V
V
nS
nS
V
V
—
—
—
—
—
—
—
—
—
—
—
—
—
4.75
-8.0
—
—
0.0
2.0
2.5
3.3
5.0
—
—
1.4:1
1.7:1
+22
+28
+43
+60
+37
+48
5.0
-5.0
25
15
-
-
±(0.3 +4% of atten.)
±(0.3 +5% of atten.)
3.1
3.8
5.8
1.7:1
2.4:1
—
—
—
—
—
—
5.25
-4.75
—
—
0.8
5.0
Digital Attenuator, 31.0 dB, 5-Bit, TTL Driver, DC - 6.0 GHz
AT90-0001
V 5.00
Absolute Maximum Ratings 1
Parameter Absolute Maximum
Max. Input Power
0.05 GHz
0.5 - 6.0 GHz
+Vcc +5.5V
-Vee -8.5V
Logic Voltages
Operating Temperature -40°C to +85°C
Storage Temperature -65°C to +125°C
1. Operation of this device above any one of these parameters
may cause permanent damange.
2. Standard CMOS TTL interface, latch-up will occur if logic
signal is applied prior to power supply.
2
-0.5 to Vcc + 0.5V
+27 dBm
+34 dBm
Pin Configuration
Pin # Function Pin # Function
1 NC 17 NC
2 C16 18 NC
3 C8 19 NC
4 C4 20 NC
5 C2 21 NC
6 C1 22 NC
7 GND 23 NC
8 NC 24 NC
9 NC 25 NC
10 NC 26 GND
11 GND 27 RF2
12 RF1 28 GND
13 GND 29 NC
14 NC 30 -Vee
15 NC 31 NC
16 NC 32 +Vcc
Truth Table
C16 C8 C4 C2 C1 Attenuation
0 0 0 0 0 Loss, Reference
0 0 0 0 1 1 dB
0 0 0 1 0 2 dB
0 0 1 0 0 4 dB
0 1 0 0 0 8 dB
1 0 0 0 0 16 dB
1 1 1 1 1 31 dB
0 = TTL Low; 1 = TTL High
Recommended PCB Layout 3
3. Application Note C2083 is available on line at
www.macom.com
NC = No Connection
Specifications subject to change without notice.
n North America: Tel. (800) 366-2266
n Asia/Pacific: Tel.+81-44-844-8296, Fax +81-44-844-8298
n Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
Visit www.macom.com for additional data sheets and product information.
2