Digital Attenuator, 15.5 dB, 5-Bit,
TTL Driver, DC - 2 GHz
AT-283
CR-12
V 5.00
Electrical Specifications1: TA = 25°C
Features
n Attenuation: 0.5 dB Steps to 15.5 dB
2
n Temperature Stability: ± 0.18 dB from –55°C
to +85°C Typical
n Low DC Power Consumption
n Hermetic Surface Mount Package
n Integral TTL Driver
n 50 O Nominal Impedance
Description
M/A-COM’s AT-283 is a GaAs FET 5-bit digital attenuator
with a 0.5 dB minimum step size and 15.5 dB total
attenuation. This attenuator and integral TTL driver is in a
hermetically sealed ceramic 16-lead surface mount package.
The AT-283 is ideally suited for use where accuracy, fast
switching, very low power consumption and low
intermodulation products are required. Typical applications
include dynamic range setting in precision receiver circuits
and other gain/leveling control circuits. Environmental
screening is available. Contact the factory for information.
Parameter Test Conditions Units Min Typical Max
Reference
Insertion Loss
DC-0.5 GHz
DC-1.0 GHz
DC-2.0 GHz
dB
dB
dB
—
—
—
—
—
—
2.2
2.5
2.9
Attenuation Accuracy 3 Any Single Bit DC-2.0 GHz
Any Combination of Bits DC-2.0 GHz
± (0.25 +3% of attenuation setting in dB) dB
± (0.25 +3% of attenuation setting in dB) dB
or ± 0.4 dB, whichever is greater
VSWR DC-1.0 GHz
DC-2.0 GHz
—
—
—
—
—
—
1.6:1
1.7:1
Trise, Tfall
Ton, Toff
Transients
10% to 90%
50% Control to 90/10% RF
In-band (peak—peak)
nS
nS
mV
—
—
—
10
27
22
—
—
—
1 dB Compression 4 Input Power 0.05 GHz
Input Power 0.5-2.0 GHz
dBm
dBm
—
—
+20
+28
—
—
Input IP3
4
For two-tone input power 0.05 GHz
up to +5 dBm 0.5-2.0 GHz
dBm
dBm
—
—
+40
+47
—
—
1. All specifications apply when operated with bias voltages of +5.0V for VCC and –5.0V to -8.0V for VEE, and 50 O impedance at
all ports unless otherwise specified.
2. Above reference insertion loss.
3. This attenuator is guaranteed monotonic.
4. VEE = -5.0V for the typical numbers given.