Macnaught RETRACTA Series 2 OA100 Instruction Manual

Thank you for purchasing a Retracta Auto Rewind Hose Reel.
The Retracta range of hose reels are a breakthrough in industrial quality hose reel design, performance, durability, versatility and cost. The efficiency, safety and convenience benefits of auto rewind hose reels are now available for most situations where a hose is required
Manufactured from the highest quality weather resistant materials, the tough high impact polypropylene is U.V. stabilised , designed for all purpose corr osion free durability. The rewind mechanism is lubricated and sealed for trouble free operation.
This retractable hose reel promotes a neat and tidy good-looking work area, reducing the possibility of accidents, and improves the work environment. Safety is enhanced by low recoil tension even with the hose fully extended.
With your appropriate care, combined with the Macnaught guarantee of dependable after sales service, you will be assured of cont inu ous safe, eff ici ent and reliable product operation.
GENERAL INFORMATION
This manual assists you in operating and maintaining your new retractable hose reel. The information contained wi ll help y ou e nsu r e ma ny y ear s of depe nda b le performance and trouble free operation.
Please take a few moments to read through this manual before installing and operating your new retractable hose reel. If you experience problems with the product, refer to the procedures contained within this instruction manual. If you require further assistance please contact your local Macnaught distributor, or local Macnaught service centre.
IMPORTANT INFORMATION
This hose reel contains a pre-tensioned spring inside the drum assembly. For safety reasons the drum assembly is a non-repairable item. DO NOT under any circumstances try to open the drum assembly. A new drum assembl y will be required if the spring is damaged.
1
RETRACTA (Series 2)
OA100 OXY-ACETYLENE HOSE REEL
0003
RP123
0107
INSTRUCTION MANUAL
Your safety is important to us. Please read, understand and follow all safety instructions listed below. Some of these instructions alert you to the potential for personal injury. “Cautions” listed throughout the manual advise of potential practices or procedures which may cause damage to your equipment.
PLEASE READ THIS IMPORTANT SAFETY INFORMATION CAREFULLY BEFORE USE.
The following additional safety information applies to the Retracta Oxy-Acetylene Reel. For your safety please read and follow the safety instructions detailed below.
Oxygen Acetylene Gas is hazardous material that can cause serio us accide nts and injur ies if proper precautions and safe practices are not followed.
Op erat ion and ma inte nanc e of Ox y Acet y len e Gasequipment should conform to the provisions of the American National Standard Z49-1 “Safety in Welding and Cutting”.
Make sure all operators have access to adequate instructions about safe operating and maintenance procedures.
1
This reel contains a positive latching mechanism, which enables the reel to be mounted in any position.
Please read and retain this instruction manual to assist you in the operation and maintenance of this quality product.
INTRODUCTION
The maximum weight of hose end tools is 2kg (4lb).
The maximum installation height is 4.5 meters (15ft) above the ground.
DO NOT exceed the maximum working pressure stated on the product label.
2
DO examine the hose, reel swivel and other equipment for damage (includ in g leaks) should a “Flashback” occur. Replacement of swivel seals is recommended. The use of “Flashback” check valves to reduce the risk of backflow and “Flashback” is also recommended.
DO use only Retracta replacement swivel components and seals as supplied by Macnaught. Obtain replacemant parts from your local Authorised Macnaught Service Centre or from Macnaught.
DO NOT allow grease and oil to come into contact with any Oxy-Acetylene equipment, components or hose. These materials ignite easily and burn violently in the presence of Oxygen.
DO NOT use pipe fitting compounds or thread lubricants in making connections.
DO NOT direct the gas flame at the hose or hose reel.
DO NOT exceed the recommended maximum Acetylene
draw off rate from the cylinder and only operate when the cylinder is upright. Liquid acetone solvent contained in the cylinder can escape and damage the hose, hose reel seals and other equipment.
DO NOT work with damaged or faulty equipment or hoses.
INSTALLATION
1) Attach the carry handle to the reel casing above the reel hose mouth, using the screws provided.
2) The reel can only be mounted in one of the following positions shown. (Refer Fig 1, 2, 3, 4 )
Fig.1 Wall / BU100 Fig.2 Overhead / BU100
If you choose the most popular positions (1) and (2) you should use the standard (BU100) bracket. If using position (3) and (4) you will need the optional bracket (BB100).
Make all connections dry. DO NOT use pipe fitting compounds, thread lubricants, oil or grease. Tighten hose connections with a spanner. Oxygen hoses use only right hand threaded connections. Note Acetylene hoses use left hand threaded connections.
CAUTION
Test the system and all connections for leaks prior to use. Re-test the system frequently (once per month approx) and on each change of gas cylinder or after maintenance.
Leak test all connections and hose reel swivels prior to initial use (refer “Gas Leak Test Procedure”) and repeat at frequent intervals. It is recommended that leak tests on all equipment be carried out at least monthly and on the replacement of cylinders and after maintenance or replacement of any equipment, component part or hose.
For O-Ring seal lubrication use only ‘Tranz’ 1434 or an equivalent inert lubricant when required. DO NOT allow oil or grease to come in contact with the swivel or Oxy-Fuel gas equipment.
SAFETY PRECAUTIONS
ONLY use this Retracta reel for the Oxy Acetylene gas
combination.
DO locate equipment in well ventilated areas.
DO run leak tests on your total system including the Hose
Re el Sw ivel freq uent ly. ( R efe r to t h e Re t rac ta Operating and Service Instructions).
DO repair or replace equipment and hoses immediately any gas leak is detected. Leaking Oxygen or Acetylene can cause serious fire and personal injury.
Up to 6ft above ground Up to 15ft above ground
Fig.3 Floor/Bench/BB100 Fig.4 High Wall/BB100
Between 1.8m (6ft) and
4.5m (15ft) above ground
3) Fix mounting bracket in required location and position reel onto bracket. (Brackets can be padlocked for additional security). Oxy Acetylene reels should only be used in well ventilated areas.
4) Connect supply hose to reel inlet allowing sufficient space for reel to swivel 180° on bracket. Swivel rotation can be avoided (in the overhead position only) by adding the locking bracket (RB9) supplied.
POSITIVE LATCH OPERATION
Pull out the hose to the required length.
Note: A clicking noise can be heard every half revolution of the drum.
To latch the reel, allow the reel to slowly retract after hearing the 1st, 2nd or 3rd click.
To unlatch the reel, slowly pull out the hose until the clicking noise stops, then let the hose slowly retract until the hose stopper rests against the reel mouth.
CAUTION
To prevent injury or damage occurring, do not let go of the hose during rewinding.
3
3) Rem ove the inl e t side plat e (R efe r Re m ova l/ Replacement Inlet Connection Side Plate).
4) Re mov e circl ip (5) fro m e nd o f s wive l s haft assembly (1) and slide the inlet shaft from the swivel body (4).
5) Carefully remove the existing O-Rings by lifting O-Rings out from grooves using a small screwdriver. With o-rings extended, cut through the O-Ring onto the screwdriver face. Be careful you do not score o-ring grooves.
Do not damage or score inlet shaft surface when removing or cutting o-ring.
CAUTION
5) Before fitting the new o-rings ensure that both the inlet shaft and swivel are thoroughly wiped clean. Apply ‘Tranz’ 1434 lubricant (supplied in kit) or equivalent to the o’ring grooves of the inlet shaft.
6) Slide the o-ring applicator sleeve (supplied in kit) over the inlet shaft to expose only the furthermost o-ring groove. Put the first o-ring onto the sleeve and slide up to the exposed groove. Withdraw the sleeve, stopping at each groove, and fit the o’rings one at a time following the same procedure.
SWIVEL RE-ASSEMBLY
7) Slide the inlet shaft back into the swivel body and replace the circlip. Note that if the circlip groove is not exposed after fitting, the swivel body is back to front.
GAS LEAK TEST PROCEDURE
Test Oxygen /Acetylene hose lines seperately. Ensure that all connections from the cylinder through to the torch are tight.
1) Close both torch valves.
2) Open the Oxygen cylinder valve and adjust the delivery pressure to 25psi or more.
3) Close the Oxygen valve and observe the delivery pres sure gaug e. If a drop in pres sur e occ urs, re-pressure the hose and test all the connections includi ng the ho se, swiv el and sw ive l bod y by brushing with warm soapy water solution looking for the presence of any bubbles.
4) Open the Oxygen valve at the torch and re-close to vent the Oxygen line. Repeat steps 1, 2 and 3 with the Acetylene, with the delivery pressure set at 10 psi. Vent the Acetylene line.
5) Replace or repair any faulty items immediately and repeat ‘Leak test’ procedure.
MAINTENANCE
This section details the step-by-step procedures that you may require for the general use and maintenance of your ree l. Please keep this instruction manual for future reference.
REMOVAL / REPLACEMENT OF INLET CONNECTION SIDE PLATE
2) Place reel on a clean bench with the inlet side plate (3) face up. Remove screw located at the edge of the inlet plate. Rotate plate clockwise.
4) To replace inlet side plate, suspend reel between your body and edge of bench. Reposition the plate and turn counter-clockwise. Relocate side screw.
3) Swivel assembly and hose will come away attached to the inlet side plate.
SWIVEL SEAL REPLACEMENT
CAUTION
Use only genuine Retracta O-Ring replacement kits. The use of any other seals can be dangerous. Ensure that the replacement procedure is carried out in an oil and grease free, clean environment.
2) Place reel on a clean bench with the inlet side plate (3) face up. Remove screw located at the edge of the inlet plate. Rotate plate clockwise.
1) Pull the hose out until it is fully extended and allow the hose to latch after hearing the 1st, 2nd or 3rd click.
1) Pull the hose out until it is fully extended and allow the hose to latch after hearing the 1st, 2nd or 3rd click.
8) Slide the inlet shaft back into the drum assembly (6), pushing the complete unit home.
9) Replace the inlet side plate. (Refer to ‘Removal / Replacement of Inlet Connection Side Plate’).
HOSE REPLACEMENT
1) Pull the hose out until it is fully extended and allow the hose to latch after hearing the 1st, 2nd or 3rd click.
2) Remove the inlet side plate (3) (Refer “Removal/ Replacement of Inlet Connection Side Plate”). The swivel shaft assembly (1) will come away attached to the inlet side plate.
3) R emo ve ho s e fro m swi vel b ody ( 4). R emov e remaining old hose from the mouth of the reel.
4) U s e onl y r eco m men ded le ngth a nd typ e o f replacement hose.
5) Feed the new hose through top of reel mouth and into opening on reel drum which gives access to the swivel compartment. Replace and secure the internal hose stopper 5” (13cm) from the end of hose assembly. Reconnect hose.
6) Re pla ce inl e t sid e plate (3) (Re fer “R emov al/ Replacement Inlet Connection Side Plate”).