![](/html/ad/adb0/adb088de2c27f3f456b84a3595cc597917cc619c1bd4ef6f98fac8aeeb3723b5/bg1.png)
MXL-INSTPR
REV 3
11/19
TYPE PR
DIGITAL REGISTER
INSTRUCTION MANUAL
- FLOWRATE INDICATOR
- TOTALIZER
To the Owner
Please read and retain this instruction manual to assist
you in the operation of this product.
This Instruction Manual provides instruction guide on the
operation and programming of the Type PR, 12mm LCD
Digital Register.
Should you require further assistance please contact you
local Macnaught representative.
Macnaught offer a comprehensive set of web based
support materials to compliment our product range.
Access the website by scanning the QR code.
WWW.MACNAUGHT.COM
![](/html/ad/adb0/adb088de2c27f3f456b84a3595cc597917cc619c1bd4ef6f98fac8aeeb3723b5/bg2.png)
INDEX
Introduction……………………………………………………………………………………………………………….………..
Functions and Features…………..……………..……………..……………..……………..……………..……………..…… 3
Configuration…………..……………..……………..……………..……………..……………..……………..……………..… 3
Display and mounting information………….……………..……………..…………..……………..…………….………….. 3
Installation………………………………..……………………………………..……………..……………..……………..…... 3
Warranty……………………………………..……………..……………..……………..……………..……………..………... 3
Technical Specifications…………….…………….…………………………………………………………………………….
General…………….…………….…………….…………………..…………..……………..……………..……………..…… 4
Display…………….…………….…………….…………….……..…………..……………..……………..……………..…… 4
Input…………….…………….…………….……………………..……………..……………..……………..……………..….. 4
Output…………….…………….…………….……………………..……………..……………..……………..………………. 4
Set-up functions…………….…………….…………….………………….…………….…………….…………….……….…..
Terminal connectors…………….…………….…………………….…………….…………….…………….……...…………
3
4
5
5
Explanation of Set-up functions…………….…………………………….…………….…………….…………….…………
Total/ Batch Total….…………….…………….………………….…………..……………..……………..……………..…… 6
Accumulated Total…………….…………….…………….……..…………..……………..……………..……………..……. 6
Flow Rate…….…………….…………….……………………..……………..……………..……………..……………..……. 6
Meter…………….…………….…………….……………………..……………..……………..……………..……………..… 6
Programming Set-up level…………….…………….……………………….…………….…………….…………….……….
Modes of operation…………….…………….………………………………..……………..……………..……………..…... 7
Function of buttons…………….…………….………………………………..……………..……………..……………..…... 7
Entering and Exiting Setup mode…….………………………………..……………..……………..……………..…………. 7
K-factor programming…………….…………….…………….………………….…………….…………….………………….
How to find a k-factor of your meter…………..……………..……………..……………..……………..……………..……. 8
Entering K-factor in the display…………..……………..……………..……………..……………..……………..…………. 8
Gallons to Litre conversion…………….…………….…………..…………..……………..……………..……………..…… 8
6
7
8
Dimensions…………….…………………………………….…………….…………….……………….…………….………….
Exploded view……………...…………………….…………….…………….…………….………………………….………….
Ordering code…………….…………….………………….…………….…………….…………….…………….……………..
Service kits…………….…………….………………….…………….…………….…………….…………….…………….…..
Troubleshooting…………….…………….…………….………….………….…………….…………….…………….……....
Replacing the battery…….…………….…………….…………..…………..……………..……………..……………..…… 10
Notes……………..…………….…………….…………….………….………….…………….…………….…………….……....
9
9
9
9
10
11
2
![](/html/ad/adb0/adb088de2c27f3f456b84a3595cc597917cc619c1bd4ef6f98fac8aeeb3723b5/bg3.png)
INTRODUCTION
FUNCTIONS AND FEATURES
The flow rate / totalizer model PR is a microprocessor driven instrument designed to display flow rate, total and
accumulated total.
This product has been designed with a focus on:
• Ultra-low power consumption to allow long-life battery powered applications.
• The glass reinforced polypropylene housing offers IP67 environmental protection.
CONFIGURATION OF THE UNIT
The PR has been designed to be implemented in many types of applications. For that reason, a SETUP-level is
available to configure your PR according to your specific requirements.
It includes several important features, such as K-factors, measurement units etc. All setting are stored in EEPROM
memory and will not be lost in the event of power failure.
DISPLAY INFORMATION
The unit has a large transflective LCD with various kinds of symbols and digits to display measuring units, status
information and key-word messages.
Flowrate and total are displayed on 12mm digits.
A backup of the total and accumulated total in EEPROM memory is made every minute.
MOUNTING EXAMPLES
Mounting on MX meter body
DISPLAY EXAMPLES
Flow rate example
Mounting on wall mount bracket
Total example
Display features Decimals and various units of measurement
INSTALLATION
The display has a unique M-lock mounting feature. It can be installed on
• MX meter body
• MX wall mount bracket
To install, secure the display on the cam and rotate quarter turn clock-wise (90 degrees)
To uninstall, hold the display and rotate quarter turn anti clock-wise (90 degrees)
There are no tools required to install/ remove the display
WARRANTY
For warranty terms & conditions, visit
https://au.macnaught.com/warranty
3
![](/html/ad/adb0/adb088de2c27f3f456b84a3595cc597917cc619c1bd4ef6f98fac8aeeb3723b5/bg4.png)
GENERAL
Display
Type High intensity reflective numeric and alphanumeric LCD, UV-resistant
Digits Seven 12mm (0.47") and seven 8mm (0.31"). Various symbols and measuring units
Refresh rate
Enclosure
General Polypropylene housing with Polycarbonate window, EPDM gaskets. UV stabilized
Control keys Two industrial micro-switch keys. UV-resistant keypad.
IP Classification IP67
Cable entry (2) x M12 * 1.5
Backlight No
Ex approvals No
Temperature
Operational -20°C to +80°C (-4°F to +176°F).
TECHNICAL SPECIFICATIONS
Flow Rate: Once per second
Total: 8 times/second after key press to one second
Power supply
Battery powered Lithium battery - life-time depends upon settings - up to 3 years @ 20°C
Battery specs 3.6 VDC, ‘A’ size, type: ER17505 (Ordering code: DR012S)
Terminal connections
2
Data protection
Environment
Electromagnetic
compatibility
Type Terminal strip. Wire max. 1mm
Type Backup of all settings and running totals in flash memory
Compliant ref: EN 61326-1:2006, EN61010-1:2001
DISPLAY
Flow rate / Total / Batch total / Accumulated total
Digits 7 digits
Units L - m3 - UKGAL - USGAL - UKbbl –USbbl - OILbbl
Decimals 0 - 1 - 2 or 3.
Flow Rate
Time units /sec - /min - /hr
Operator functions
Flow Rate.
Total (can be reset to zero by the operator).
Displayed functions
Batch total (can be reset to zero by the operator)
Accumulated total (non resettable)
(Note: Total and Batch total can be reset to zero)
INPUT & OUTPUT
Input
Input Reed switch (from flow meter)
Frequency
K-Factor 0000.001 - 9,999.999 pulses per Litre
Output
Output Nil
Total: minimum 0 Hz - maximum 120 Hz for total
Flow Rate: 0.01 Hz – maximum 120 Hz
4