Essential Reading
Section A: The XCi Device
Section B: Doppler Ultrasonic Velocity Sensors
- Only necessary if installing MACE Doppler ultrasonic velocity sensors
Section C: Flocom+ Software
Section D: FloSeries3 Cards
- Chapter 14.0 Introduction to FloSeries3 cards
- Chapter 15.0 Installing FloSeries3 cards
- The chapter/s relevant to the FloSeries3 card/s in your XCi device
MACE XCi Product Manual
Product Support
Should you experience diculty in using this product, please contact your local MACE vendor. We also welcome feedback from customers who feel that their experience may provide an improvement to the product or may be benecial to other users.
NOTE: MACE strongly recommends that users register for Software Updates on the “Support” page of the www.macemeters.com website. Releases of product enhancements occur periodically and we recommend that these are uploaded into your XCi device.
Please go to www.macemeters.com
Disclaimer
No warranties of any nature are extended by this document.
Measuring and Control Equipment Co. Pty. Ltd. (MACE) will not accept any nancial or other responsibility that may be the result of your use of this information, including direct, indirect, special or consequential damages.
You must be careful to ensure that the use of this information complies with the laws, rules and regulations of the jurisdictions with respect to which it is used. MACE assumes no responsibility for personal or property damage caused by the misuse of this equipment.
Copyright
Information in this document is subject to change without notice. The software described in this document is furnished under a license agreement or nondisclosure agreement. The software may be used or copied only in accordance with the terms of those agreements. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or any means electronic or mechanical, including photocopying and recording for any purpose other than the purchaser’s personal use without the written permission of Measuring & Control Equipment P/L.
Copyright © 1996-2011. MACE P/L. All rights reserved.
Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
WARNINGS
Water damage
MACE recommends that the XCi device be mounted above known ood peak levels. MACE will not be liable for damage caused by ooding. (The unit is weatherproof, but NOT waterproof and should NOT be submerged).
Sunlight
MACE recommends that the XCi device be mounted so that the LCD faces in a direction away from direct sunlight (ie South in the Southern Hemisphere and North in the Northern Hemisphere).
Cable damage
MACE recommends that all cables be appropriately routed through electrical conduit or other similar mechanism. MACE will not be liable for damage to cables, especially if it is caused by vehicles, digging implements, animals or debris in the pipe or channel.
Insects and moisture
After the XCi system has been installed and fully tested, MACE recommends the use of expanding “space ller” foam down the rst 5 to 10cm (2 to 4 “) of the conduit or mounting pole to prevent insect/moisture ingress.
Battery life
Care must be taken when a mains power supply is used to charge the internal battery instead of a solar panel. If the mains power remains disconnected for an extended period of time, the internal battery may be permanently damaged.
Electromagnetic compatibility (EMC)
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Intrinsic Safety
The XCi is NOT an intrinsically safe instrument and should not be installed in hazardous (explosive) environments. Should an intrinsically safe instrument be required, MACE can oer other instruments with this approval level.
MACE XCi PRODUCT MANUAL MACE XCi PRODUCT MANUAL
About Doppler ultrasonics
MACE XCi devices utilise the Doppler Eect to measure velocity of stream ows.
The Doppler Eect (after C. J. Doppler 1803-53) is dened as, “the apparent change in the frequency of sound or electromagnetic radiation due to relative motion between the source and the observer” (Uvarov & Isaacs (1986). Dictionary of Science).
The MACE Doppler ultrasonic velocity sensors transmit an ultrasonic (sound) wave into the ow. This sound wave is reected by acoustically reective particles (e.g. air bubbles, suspended solids) and the instrument detects the reected frequencies. The dierence between the transmitted frequency and the received frequencies is directly proportional to the velocity of the stream ow.
In full or partially full pipes, the velocity of the stream ow varies markedly across the cross-section of the pipe. Typically, velocity is zero along the wall of the pipe and increases to a maximum at or about the centre of the pipe. MACE Doppler ultrasonic velocity sensors receive reected frequencies from particles moving at these dierent velocities. The greater the area of ow moving at a particular velocity, the greater the number of reections with the respective frequency shift. The average velocity of the stream is therefore calculated by averaging those frequency reections received across the whole stream prole.
In laymans terms a simple analogy for the way MACE Doppler ultrasonics operate is that it’s similar to “switching on a ashlight in a fog”. Any reective particle that moves within the “beam” will be seen by the ultrasonic sensor. MACE Doppler ultrasonic velocity sensors provide a true average stream velocity.
About MACE
MACE is an family company founded in 1968 by electrical and mechanical engineer Lawrence Campbell who recognized the importance of ow measurement and ow monitoring in the global environment.
For 40 years MACE has designed and manufactured electronic monitoring instrumentation including ultrasonic ow meters, data loggers and controllers. Continued commitment to research and development over the past three decades has ensured MACE’s provision of the most advanced high technology equipment for the agricultural, industrial and environmental markets.
MACE has a core team of research and development engineers who are focused on providing customer driven products that are both easy to use and withstand the test of time in often remote and harsh environmental conditions.
MACE is committed to providing its clients with personalized service, training and technical back-up to ensure successful monitoring.
MACE continues to innovate with the introduction of the new XCi Multiple Card Interface found in all our new range of ow meters and data loggers. XCi enables the user to connect just about any environmental sensor quickly and easily. This oers the customer a highly exible, cost eective water monitoring solution.
With the addition of a new MACE WebComm card to any XCi device, customers are able to access their data remotely for free from the MACE website.
MACE XCi PRODUCT MANUAL MACE XCi PRODUCT MANUAL
Loading...
+ 9 hidden pages