Indice
1 Avvertenze - Warning ................................................................................................................ 3
2 Guida all’acquisto - Guide to purchase .................................................................................... 4
3 Contenuto della confezione - Package contents ..................................................................... 4
4 Guida Rapida per messa in funzione - Start Up procedure .................................................... 5
4.1 Installazione Idraulica - Hydraulic Installation ......................................................................... 5
4.2 Installazione elettrica - Electrical Installation ........................................................................... 5
4.3 Installazione Software - Software Installation ......................................................................... 6
5 Generalità - General Remarks ................................................................................................... 9
5.1 Descrizione del Prodotto - Product Description ....................................................................... 9
5.2 Condizioni di Esercizio - Usage Condition ............................................................................ 10
5.3 Caratteristiche Tecniche - Technical Features ...................................................................... 11
5.4 Protezioni - Protections ................................................................ ........................................ 12
6 Funzionamento ed Impiego - Functioning and Use............................................................... 13
6.1 Collegamento idraulico - Hydraulic connection ..................................................................... 13
6.2 Collegamento elettrico - Electrical Connection...................................................................... 15
6.3 Suggerimenti - Tips .............................................................................................................. 19
7 Collegamenti aggiuntivi - Additional connections ................................................................ 19
7.1 Configurazione Galleggiante di minima - Dry running float Configuration.............................. 19
7.2 Configurazione Relè - Relay Configuration ........................................................................... 19
7.3 Configurazione Booster (pompa ON/OFF) - Booster Configuration (ON/OFF pump) ............ 20
7.4 Configurazione modalità Multipompa - Multipump Configuration .......................................... 23
8 Menu software - Software Menu ............................................................................................. 26
9 Ricerca Guasti e Manutenzione - Troubleshooting & Maintenance ..................................... 26
10 Menu Esteso - Extended Menu ............................................................................................... 30
10.1 Tabella Parametri - Parameter Table .................................................................................... 32
11 DICHIARAZIONE DI CONFORMITÀ- CONFORMITY DECLARATION .................................... 35

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
3
1 Avvertenze - Warning
PERICOLO
Rischio di danni alle persone, e alle cose se non
osservate quanto prescritto
SCOSSE ELETTRICHE
Rischio di scosse elettriche se non osservate
quanto prescritto
DANGER
Risk of personal injury and property if not
complied with the requirements
ELECTRIC SHOCK
Risk of electrical shock if not complied with the
requirements
AVVERTENZA
Rischio di danni alle cose o all'ambiente se non
osservate quanto prescritto.
WARNING
Risk of damage to property or the environment
if not complied with the requirements.
AVVERTENZA
Prima di installare e utilizzare il prodotto leggere
attentamente il presente manuale in tutte le sue
parti. L’installazione e la manutenzione devono
essere eseguite da personale qualificato nel
rispetto delle norme vigenti.
Mac3 non risponde di danni provocati da un uso
improprio o proibito di EPOWER e declina ogni
responsabilità per danni provocati da una non
corretta installazione e manutenzione di impianto.
L’uso di ricambi non originali, manomissioni o usi
impropri fanno decadere la garanzia.
WARNING
Before installing and using the product read
this book in all its parts. Installation and
maintenance must be performed by qualified
personnel in accordance with current
regulations.
MAC3 will not be held responsible for any
damage caused by improper or prohibited use
and is not responsible for any damages
caused by a not correct installation or
maintenance.
The use of non-original spare parts, tempering
or improper use, make the product warranty
null.
AVVERTENZE
EPOWER deve essere installato secondo il
paragrafo “Funzionamento ed impiego”
L’installazione dell’inverter EPOWER in un
impianto idraulico deve essere opportunamente
progettata in modo da evitare sovrapressioni
dovute a colpi di ariete. Gli ammortizzatori installati,
per proteggere da sovrapressioni, devono essere
correttamente mantenuti.
L’inverter è un dispositivo elettrico, se la struttura
meccanica dell’Epower viene danneggiata da
sovrapressioni, eventuali infiltrazioni di acqua
possono essere dannose a causa contatto dei
componenti elettrici e l’acqua in circolo.
WARNING
EPOWER must be installed as described in
the paragraph “Functioning and Use”
You must project correctly the hydraulic
connection of EPOWER to avoid pressure
shocks. The shock absorber, installed to avoid
pressure shocks, must be keep under a
correct maintenance.
Epower is an electric device, if the case will be
damage by pressure shocks a possible water
infiltration could be dangerous due to the
contact between electric components and the
water flow.
PERICOLO
EPOWER è marchiato CE ma in caso di non
corretta installazione può causare interferenze
elettromagnetiche.
Verificare il corretto funzionamento di altri
dispositivi con EPOWER acceso ed in funzione.
Il malfunzionamento di apparecchiature può essere
dannoso per cose e persone.
Nel caso di interferenze elettromagnetiche
contattare l'assistenza tecnica e spegnere
l'impianto.
Prima di ogni intervento accertarsi che EPOWER
sia scollegato dall’alimentazione elettrica.
Non effettuare manovre con EPOWER aperto.
L’allacciamento di EPOWER al quadro elettrico
deve essere eseguito da personale qualificato nel
rispetto delle norme vigenti.
EPOWER deve essere protetto da un interruttore
termico.
EPOWER deve essere collegato ad un efficiente
impianto di terra.
DANGER
EPOWER is CE labelled but in the case of
wrong installation can cause electromagnetic
interference.
Verify the correct operation of other electronic
devices with EPOWER on and running.
Malfunction of equipment can be harmful to
people and property.
In the case of electromagnetic interference
contact technical support and stop the plant.
Before any intervention censure that the
EPOWER is disconnected from the electricity
supply
Do not attempt operations with the EPOWER
open
The connection of the EPOWER to the electric
panel must be carried out by qualified
personnel in accordance with current norms
EPOWER must be protected by a thermal
switch.
EPOWER must be connected to an efficient
earthing system

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
4
2 Guida all’acquisto - Guide to purchase
I Ringraziando per la scelta accordata al nostro inverter
Epower. Segnaliamo alcune informazioni per l’uso e
l’installazione del prodotto e gli accessori disponibili.
1.Scelta della pompa: per poter sfruttare correttamente le
prestazioni di un inverter si deve porre attenzione nella scelta
della pompa.
Un inverter per sua natura pilota la pompa su frequenze
differenti con il variare della richiesta di portata ed è questa
la ragione per cui si ha un risparmio energetico ed una minor
usura del sistema di pressurizzazione. Per avere dei
comportamenti corretti si deve quindi scegliere pompe con
curva caratteristica accentuata (vedi fig.), solitamente
multigiranti, che permettano all’inverter di pilotare la pompa
con frequenza variabili. La portata e la prevalenza della
pompa devono essere adeguate alla esigenza dell’impianto.
EN Thanks to have bought Epower! We would like to
notice some useful information to correctly use and
install Epower and the available accessories.
1. How to choose pump: to take advantage of
performance of Epower it is essential to choose the
correct pump.
The inverter pilots the pump on several frequencies
depending on the variation of flow. This is why it is
possible to save energy and to increase life time of the
pump.
For having correct behaviours it is essential to choose a
pump with slope characteristic curve (see fig.), usually
multiimpeller pumps; this kind of pump permits the
Epower to pilots pump at variables speed.
The head and capacity of the pump must correct for
request of the plant.
2. Adattatore per connessioni lunghe (ACL): Per diminuire
le sovratensioni che si creano utilizzando cavi lunghi tra
inverter e pompa, si consiglia l’uso del filtro ACL per poter
prolungare la vita del motore.
Con lunghezze di cavo da 20 metri a 100 metri si consigli
l’uso del filtro, oltre i 100 metri di cavo l’uso del filtro diventa
obbligatorio.
3.Filtri EMI: Gli inverter Mac3 sono certificati EMI per uso
domestico.
In caso di installazione in ambienti particolarmente sensibili
ai disturbi elettromagnetici Mac3 rende disponibili dei filtri
EMI aggiuntivi, da installare fra l’alimentazione e l’inverter in
modo da annullare eventuali disturbi.
2. Long Connection Adapter (LCA): To reduce
overvoltages created by using long cables between the
inverter and the pump, we recommend using the ACL
filter to prolong the life of the motor.
We recommend to use the filter with cable lengths from
20 meters to 100 meters, the use of the filter over 100
meters of cable is obligatory.
3.EMC filter: Mac3 inverters have domestic use EMC
approval.
If inverter is installed in enviroments particularly sensitive
to electromagnetic interference Mac3 makes available
additional EMI filters, to be installed between the supply
and inverter, so as to eliminate.
3 Contenuto della confezione - Package contents
I Epower è fornito su tubo metallico da 1 ¼” e morsettiere
facilmente accessibili per cablaggio elettrico
EN Epower is provided on metal pipe 1 ¼ "and easily
accessible terminals for wiring.

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
5
4 Guida Rapida per messa in funzione - Start Up procedure
4.1 Installazione Idraulica - Hydraulic Installation
I di seguito uno schema a titolo di esempio, per maggiori
dettagli ed avvertenze vedi paragrafo “Funzionamento ed
Impiego” .
EN Hereafter a scheme, as example, for more details
and warnings see the section "Functioning and Use"
4.2 Installazione elettrica - Electrical Installation
I di seguito uno schema a titolo di esempio, per maggiori
dettagli ed avvertenze vedi paragrafo “Funzionamento ed
Impiego”
EN Hereafter a scheme, as example, for more details
and warnings see the section "Functioning and Use”.
Cavo Alimentazione
Power Supply Cable
Alimentazione
Power Supply
Valvola di ritegno
Check valve

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
6
4.3 Installazione Software - Software Installation
Uso della tastiera Keyboard use
Permette di mettere in stand by il dispositivo e
togliere l’alimentazione alla pompa.
- Tenere premuto per 5 secondi:
Luce accesa: dispositivo in funzione
Luce spenta: dispositivo in stand by
To set the device in stand by and switch off
the pump.
- Keep pressed for 5 seconds:
Light on: device is operating
Light off: device in stand by
Permette di passare da modo display a modo
modifica:
Premere 1 sec. per vedere il valore impostato
Premere per 5 sec. per andare in modifica
Premere una seconda volta per salvare il valore e
tornare in visualizzazione
It allows to switch from display mode to set
mode:
Press for 1 second to see the value set
Press for 5 sec. to enter into set mode
Press a second time to save the value and
return to display mode
+/Se led SAVE/DISPLAY verde: Permette di scorrere
fra i parametri
Se led SAVE/DISPLAY rosso: permette di
modificare il valore del parametro selezionato
If LED SAVE / DISPLAY green: it Allows to
scroll through the parameters
If LED SAVE / DISPLAY red: it allows to
change the selected parameter value.
+ e – scorre i parametri e varia
i valori impostati.
Keys + and – scroll the parameters
and change the set values
Bottone SAVE/DISPLAY: per modificare e
salvare il valore impostato
SAVE/DISPLAY Button: to change and to
save the set value
Bottone di ON / OFF: per mettere
in stand by l’inverter
ON/OFF button: to put on standby
the VFD
Led acceso rosso: segnala allarme
Led flashing red: indicates alarm
Pressione di impianto
System Pressure
Pressione di ripartenza.
Restart pressure
Frequenza Frequency
Corrente del motore
Motor Current
Led indicatori per il valore mostrato dal display.
Led indicators for the value shown on the display.

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
7
Procedura Procedure
I Alimentare l’apparecchio e dopo 2 secondi compare il
modello del dispositivo e la versione del software.
EN Power the EPOWER and in 2 seconds it will be
displayed the model of the device and the version of the
software.
Compare il valore della Corrente da impostare. Premere il
tasto + per aumentare il valore e – per diminuirlo.
Premere il tasto SAVE per salvare il valore e passare al
successivo.
Displayed the value of current to be set. Press the +
button to increase the value and - to decrease.
Press the SAVE key to save the value and move to the
next.
Compare il valore della Pressione di Impianto da
impostare. Premere il tasto + per aumentare il valore e – per
diminuirlo. Premere il tasto SAVE per salvare il valore e
passare al successivo.
Displayed the value of System Pressure to be set. Press
the + button to increase the value and - to decrease.
Press the SAVE key to save the value and move to the
next.
Compare il valore della Pressione di Ripartenza da
impostare. Premere il tasto + per aumentare il valore e – per
diminuirlo. Premere il tasto SAVE per salvare il valore. E’
terminata la procedura di installazione.
Displayed the value of Restart Pressure to be set. Press
the + button to increase the value and - to decrease.
Press the SAVE key to save the value. The installation
procedure is finished.
Il dispositivo salva i parametri e compare la scritta OF(off).
La pompa non è alimentata.
The device saves the parameters and displays OF (off).
the pump is not powered. activates the pump.
Per attivare la pompa premere il tasto ON/OFF fino a che sul
display non compare ON.
To activate the pump push the ON/OFF button till the led
display shows ON..
Sul display a led viene visualizzato il valore della pressione
misurata di impianto.
The LED display shows the value of the measured
pressure of system.
Durante il funzionamento è possibile leggere i valori misurati
dei parametri (pressione in impianto, pressione di ripartenza,
corrente assorbita dalla pompa e frequenza a cui sta girando
la pompa) semplicemente premendo i tasti +/-.
Per leggere i valori impostati dei parametri premere il tasto
SAVE/DISPLAY per 1 secondo. Il legame fra valore
visualizzato e il parametro è identificato dalla accensione del
led corrispondente.
During operation, you can read the measured values of
the parameters (pressure in the system, restart
pressure, current consumption of the pump and
frequency at which the pump is running) by pressing the
+ / - keys.
To read the values set of the parameters press the
SAVE / DISPLAY button for 1 second. The link between
the value displayed and the parameter is identified
accordingly by the LED flashing.

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
8
Senso di rotazione
Nel caso in cui sia necessario invertire il senso di rotazione
della pompa è possibile farlo via software entrando nel menu
esteso (vedi parametro “Senso di rotazion”)
NB:
Affinchè l’Epower sia configurato
correttamente, dopo la procedura
d’installazione, è necessario far lavorare la
pompa al massimo dei giri per almeno 60
secondi. In questo modo l’ePower
memorizzerà il massimo valore della
potenza assorbita dalla pompa.
Rotation sense
In case of need to reverse the rotation sense of the
pump is possible to do so via software, entering the
extended menu (Parameter “Rotation sense”)
NB:
In order for Epower is configured
properly after the installation, you need
to work the pump at full speed for 60
seconds. In this way the Epower will
store the maximum value of the power
absorbed by the pump

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
9
5 Generalità - General Remarks
I Col presente manuale intendiamo fornire le informazioni
indispensabili per l’installazione, l’uso e la manutenzione del
prodotto Epower.
E’ importante che l’utilizzatore e/o l’installatore legga questo
manuale prima di installare ed usare il prodotto. Un uso
improprio può provocare avarie e determinare la perdita della
garanzia.
Precisare sempre l’esatta sigla di identificazione del modello
qualora debbano essere richieste informazioni tecniche o
particolari di ricambio al nostro Servizio di vendita e
assistenza.
Per istruzioni, situazioni ed eventi non contemplati dal
presente manuale, contattare il Servizio di assistenza.
EN This manual intends to provide essential information
for the installation, use and maintenane of the Epower.
It is important that the user and/or installer carefully
reads the manual before installing and using the product.
Incorrect use may cause faults and result in the
annulment of the guarantee terms.
Always specify the exact identification of the model if
transit requests for technical information or spare parts
from our sales and service support.
In the event of instructions, situations and events not
contemplated in the present manual, please contact
technical customer support.
5.1 Descrizione del Prodotto - Product Description
I . L’Epower è un regolatore di velocità a frequenza variabile
(inverter) per gruppi di sollevamento a pressione costante.
Epower, in funzione della richiesta idrica, provvede alla
regolazione automatica del numero dei giri dell’elettropompa
mantenendo costante la pressione nell’impianto.
Epower è disponibile nelle seguenti versioni:
EPOWER-MM: inverter su condotta d’acqua con
alimentazione monofase per pompa monofase.
EPOWER-MT: inverter su condotta d’acqua con
alimentazione monofase per pompa trifase.
Gruppi di pressurizzazione
E’ possibile installare EPOWER per il pilotaggio di una
seconda pompa in ON/OFF a velocità fissa (pompa
booster). Per una corretta installazione seguire le
indicazioni dello schema elettrico e le istruzioni di
riferimento al paragrafo “Collegamenti aggiuntivi”. Mac3
propone sul proprio catalogo un quadretto di comando
pompa già predisposto per questa applicazione.
E’ possibile installare ePower in configurazione Multi
Pompe (modello ADVANCED) per il pilotaggio fino a 8
pompe. La configurazione ADVANCED è composta da
un inverter Master che pilota fino ad un massimo di 7
inverter Slave. L’inverter Master determina il
funzionamento degli inverter Slave.
N.B: L’installazione deve essere eseguita da
personale tecnico qualificato
IMPORTANTE: Le pompe utilizzate devono essere di
pari caratteristiche: potenza motore (hp), prevalenza
(Hmax).
Attraverso il dispositivo "Wifi Bridge" acquistabile
separatamente , è possibile connettere l’EPower alla rete
internet permettendo il controllo a distanza dell'inverter
tramite PC o smartphone.
EN The Epower is a variable frequency drive (inverter)
for lifting units under constant pressure.
Epower, according to the actual water requirements
undertakes the automatic regulations of the number of
revs of the electro-pump whilst maintaining the system
pressure constant.
The Epower is available in the following versions:
EPOWER-MM: inverter water coooled, single-
phase line for single-phase pump.
EPOWER-MT: inverter water coooled, single-
phase line for three-stage pump.
Pressurization groups
The Epower allows to drive a second pump ON/OFF
at a fixed rate (booster pump). For correct
installation, follow the wiring diagram and
instructions refer to paragraph “Additional
connections”. Mac3 has in the catalog a control
panel specifically design for this application.
A multipump configuration (ADVANCED model) is
available for running till 8 pumps.
The ADVANCED version is composed by a Master
that pilots till 7 Slaves.
The inverter Master determines the function of the
system.
NB: Installation must be performed by qualified
personnel
IMPORTANT: The pumps used must be of the same
characteristics: power engine (hp), head (Hmax).
You can connected the EPower on internet allowing
remote control of the inverter via PC or smartphone
with the device "Access Bridge", sold separately.

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
10
5.2 Condizioni di Esercizio - Usage Condition
I Temperatura ambiente: compresa tra 0°C e +40°C
Umidità relativa massima: 50% a +40°C (senza condensa)
Temperatura liquido pompato: compresa tra +1°C e +40°C
Natura del liquido pompato: Acqua priva di sostanze
chimicamente aggressive (ph 5÷9) e di solidi in sospensione.
AVVERTENZE
EPOWER deve essere installato in ambienti protetti dalle
intemperie e dal gelo.
L’installazione dell’inverter EPOWER in un impianto idraulico
deve essere opportunamente progettata in modo da evitare
che sull’inverter si abbiamo sovrapressioni dovute a colpi di
ariete. Gli ammortizzatori devono essere correttamente
mantenuti.
EPOWER non può essere utilizzato su condotti con liquidi
abrasivi, sostanze solide fibrose, liquidi infiammabili ed
esplosivi
EN Operational temperature:0°C ÷ +40°C
Max.humidity: 50% at 40°C (no condensate)
Temperature of fluid: +1°C +40°C
Nature of fluid: water with no chemical add (ph 5÷9)and
no debris.
WARNING
EPOWER must be installed in environments that are
protected from freezing and weather-proof.
You must project correctly the hydraulic connection of
EPOWER to avoid pressure shocks. The shock
absorber, installed to avoid pressure shocks, must be
keep under a correct maintenance.
EPOWER cannot be used on pipes containing abrasive
liquids, fibrous solid substances or inflammable liquids or
explosives.

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
11
5.3 Caratteristiche Tecniche - Technical Features
Sicurezza elettrica
Compatibilità
elettromagnetica
EN60730
EN61000-6-3
EN61000-6-4
Electrical safety
Electromagnetic
compatibility
EN60730
EN61000-6-3
EN61000-6-4
1x230 Vac 50/60 hz
(da 170 a 270 Vca)
1x230 Vac 50/60 hz
(170 ÷ 270 Vca)
Potenza max. Pompa (P2)
230 Vac monofase
Max Pump Power (P2)
230Vac single phase
1x230 Vac 50/60 hz
(da 170 a 270 Vca)
1x230 Vac 50/60 hz
(da 170 a 270 Vca)
Potenza max.Pompa (P2)
230Vac trifase
Max Pump Power (P2)
230Vac three-phase

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
12
5.4 Protezioni - Protections
I In caso di condizioni anomale Epower protegge l’autoclave
spengendosi, ma per salvaguardare la fornitura, effettua
tentativi di ripristino automatici o programmabili.
EN In the event of anomaly conditions Epower protects
the autoclave by switching off, but to ensure water,
attempts automatic or programmed reset operations.
Tensione alimentazione
troppo bassa
Automatico (vedi”Ricerca Guasti e
Manutenzione”)
Automatic (see “Troubleshooting
& Maintenance”)
Tensione alimentazione
troppo alta
Automatico (vedi”Ricerca Guasti e
Manutenzione”)
Automatic (see “Troubleshooting
& Maintenance”)
tentativi di riarmo automatici*.
Automatic attempts (n°
programmable - factory default 5);
on exhausting the reset attempts
you need to restart manually*
Corrente di uscita sovra
soglia oltre 1 min.
tentativi di riarmo automatici *.
Output current above
threshold for over 1 min.
Automatic attempts (n°
programmable - factory default 5);
on exhausting the reset attempts
you need to restart manually*
Temperatura acqua
oltre 75 °C
Automatico (vedi”Ricerca Guasti e
Manutenzione”)
Water temperature
above 75 °C
Automatic (see “Troubleshooting
& Maintenance”)
Pressione insufficiente
nell’impianto
tentativi di riarmo automatici *.
Insufficient pressure in
the system
Automatic restart attempts *
Mancanza di acqua
Aria nella pompa
tentativi di riarmo automatici *.
Lack of water or air in
the pump
n° programmable attempts**
Guasto del sensore di
pressione
tentativi di riarmo automatici *.
Antigrippaggio
(solo vers.MM)
Se la pompa si arresta per almeno
24 ore,l’inverter riavvia la pompa
innalzando la pressione di 0.5 bar
If the pump is stopped for more
than 24 hours, the device restarts
the pump raising the pressure of
0.5 bar
La pompa è rimasta accesa
continuamente per il tempo
impostato al parametro 40. Per
ripristinare il funzionamento
dell’inverter è necessario il riarmo
manuale*.
The pump has been in operation
continuously for the time set in
parameter 40. Manual reset is
required* to exit from the alarm.
* numero di tentativi di riarmo automatici programmabile default di fabbrica 5.
Esauriti i tentativi automatici è necessario:
1. togliere alimentazione
2. attendere lo spengimento del display
3. ridare alimentazione
* programmable number of automatic restart attempts factory default 5).
On exhausting the reset attempts you need to :
1. disconnect power
2. wait for display to switch off
3. re-power

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
13
6 Funzionamento ed Impiego - Functioning and Use
6.1 Collegamento idraulico - Hydraulic connection
I Epower può essere installato in qualunque posizione. Si
consiglia comunque il posizionamento verticale. In caso
fosse necessario avere il dispositivo in posizione orizzontale,
si raccomanda di installarlo con una lieve inclinazione,
poiché su tratti di tubazione orizzontale e
contemporaneamente con bassi prelievi d’acqua (3-5
litri/minuto), si potrebbe avere un aumento significativo della
temperatura, che manderebbe il dispositivo in protezione.
Avvertenze:
- Accertarsi del perfetto adescamento dell’elettropompa,
prima di installare EPOWER.
- Installare EPOWER nelle vicinanze della pompa; se
montato direttamente sulla pompa verificare che non
siano presenti vibrazioni nocive.
- Usare tubazioni di diametro non inferiore a quelle degli
attacchi di EPOWER.
- Evitare luoghi dove e’ possibile la formazione di
condensa
- Installare un vaso di espansione (capacità minima
consigliata 8lt) per proteggere il prodotto da eventuali
colpi di ariete e per evitare continui riavii
dell’elettropompa in presenza di piccole perdite.
Es. dimensionamento in base alla pressione di lavoro:
Pompa da 6 bar vaso d’espansione da 10bar
Es. di dimensionamenti in base ai litri minuto della pompa:
Pompa da 100lt/min vaso d’espansione da 10lt/min
(10% della portata massima della pompa)
Valore di precarica del vaso d’espansione deve essere circa
0,8 x valore di pressione di impianto.
Es.
Pressione di impianto = 3bar
Pressione di ripartenza = 2,6bar
valore di precarica del vaso = (0,8 x 3) = 2,4bar
Se per esigenze di impianto la pressione di ripartenza e’
almeno 1 bar inferiore alla pressione di impianto, allora il
valore di precarica del vaso d’espansione deve essere circa
0,8 x valore di pressione di ripartenza.
Es.
Pressione di impianto = 3bar
Pressione di ripartenza = 2bar
valore di precarica del vaso = (0,8 x 2) = 1,6bar
Note per l’installazione
- Consigliabile montare un rubinetto di prelievo.
- Inserire di un filtro a cartuccia per proteggere sia
l’impianto che il dispositivo da impurità sempre presenti
nell’acqua (Nota1)
- L’inserimento di una valvola di non ritorno esterna è
obbligatorio.
- Per una facile manutenzione montare l’inverter
utilizzando raccordi a 3 pezzi
- Montare una saracinesca di servizio in prossimità
dell’inverter per facilitare i controlli
- Montare una saracinesca in serie al vaso d’espansione
per facilitare la manutenzione
EN Epower can be installed in any position. However,
we recommend the vertical positioning. In case you need
to have the device in a horizontal position, it is
recommended to install it with a light inclination, because
in horizontal sections of pipe and simultaneously with
low water flow (3-5 liters / minute), you could have a
significant increase in temperature, which would bring
the device in protection.
Warnings:
- Make sure pump is perfectly primed, before installing
EPOWER.
- Install EPOWER near the pump; if installed directly
on the pump, verify that there are no harmful
vibrations.
- Use tube diameter not less than those of EPOWER
attacks.
- Avoid places where is possible precence of
condensation
- Install an expansion tank (minimum
recommended capacity 8lt) to protect the product
against water hammer and to avoid continuous
restarting in presence of small losses.
Eg. Size, according to pressure of work:
Pump 12 bar expansion tank 20 bar
Eg. Size, in liters per minute according to the pump:
Pump 100lt/min expansion tank from 10lt/min
(10% of the maximum flow of the pump)
Preload value of the expansion tank should be about 0.8
x value of system pressure.
Eg.
System pressure = 3 bar
Restart pressure = 2.6 bar
value of precharge = (0.8 x 3) = 2.4 bar
If the restart pressure is at least 1 bar lower than the
system pressure, then the precharge value of the
expansion tank should be about 0.8 x pressure value of
restart pressure.
Eg.
System pressure = 3 bar
Restart pressure = 2 bar
value of precharge = (0.8 x 2) = 1.6 bar
Installation Notes
- Recommended to install a tap sampling.
- Insert a cartridge filter to protect both the system that
the device from impurities, always present in the
water (Note1)
- The inclusion of an external check valve is
mandatory.
- For easy maintenance, mount the drive using a 3piece union fittings
- Install a tap near the drive to facilitate the control of
the drive
- Install a gate valve in series with the expansion tank
for easy maintenance

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
14
Nota1: l’acqua contiene sempre sabbia trucioli di ferro e corpi estranei
dette impurità non dovrebbero penetrare nell’impianto idraulico perché
provocano corrosioni nelle tubazioni danneggiando le apparecchiature
collegate alla rete idraulica. La filtrazione dell’acqua per uso domestico
è prescritta dalla normativa UNI-CTI 8065 nonché dal decreto del
ministero della salute del 21-12-1990. Installare un filtro non è un
optional ma una precisa disposizione.
Di seguito schema Impianto tipico con pompa di
superficie sotto battente
Note 1: The water always contains sand, iron, debris; such
impurities should not enter the hydraulic system because they
cause corrosion of pipes, damaging the equipment connected to
plumbing.
Water filtration for domestic use is required under the UNI-CTI
8065 and by decree of the Ministry of Health of 12.21.1990.
Installing a filter is not an option but a provision.
Hereafter a typical system diagram with surface
pump suction head

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
15
6.2 Collegamento elettrico - Electrical Connection
EPower MM
I Il dispositivo è fornito con due morsettiere (Linea/Pompa)
accessibili attraverso uno sportellino, con pressacavi
incorporato, che viene tenuto al dispositivo tramite viti.
Togliere lo sportello, mettere in luce le morsettiere e
passando i cavi nei rispettivi passacavi :
- Connettere il cavo di uscita (terra, linea monofase) alla
pompa. Utilizzare i morsetti indicati come “W e V”
per il collegamento alla pompa monofase.
EN The device is provided with two terminals (line /
pump) accessible through a door with built-in cable
glands, which is connected to the device with screws.
Remove the door, exposing the terminal and passing the
cables in their cable glands:
- Connect the output cable (ground, single phase)
to the pump. Use the terminals “V and W” for
the single-phase pump.
Utilizzare i morsetti “W e V” per il
collegamento alla pompa monofase.
Use the terminals “V and W” for the
single-phase pump.

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
16
I Connettere il cavo di ingresso (fase,neutro, terra) alla rete
monofase tramite un interruttore termico dimensionato in
funzione della targa della pompa.
Di seguito uno schema di collegamento a titolo di esempio.
EN Connect the input cable (phase, neutral, ground) to
the single-phase line through a circuit breaker sized
according to the pump rating.
Hereafter an electrical link schema just for example.
- Richiudere lo sportello facendo attenzione alla corretta
posizione dell’O-Ring. E’ necessario rispettare il verso
corretto di montaggio dell’O-Ring per evitare eventuali
infiltrazioni d’acqua.
- Dopo aver accostato in maniera uniforme lo sportello
all’O-ring, proseguire con il serraggio.
NB: Al fine di evitare possibili problemi di
condensa e per evitare eventuali infiltrazioni
d’acqua, è necessario avvitare a croce le viti di
chiusura utilizzando una coppia di serraggio
compresa tra 0.25÷0.35Nm, consigliato 0.30Nm.
(vedi la sequenza in figura).
-
- Close the door and ensure the correct position of
the O-Ring. To prevent any water infiltration is
necessary to respect the correct assembly of the
O-Ring.
- After having approached the door uniformly on the
O-ring, continue the tightening.
NB: To avoid condensation problems and to
prevent the possible water infiltration, you
need to tighten the screws using a torque
between 0.25 to 0.35Nm, recommended
0.30Nm.
(see the sequence in figure)
-

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
17
EPower MT
I Il dispositivo è fornito con due morsettiere (Linea/Pompa)
accessibili attraverso uno sportellino, con pressacavi
incorporato, che viene connesso al dispositivo tramite viti.
Togliere lo sportello, mettere in luce le morsettiere e
passando i cavi nei rispettivi passacavi :
- Connettere il cavo di uscita (terra, terna trifase)
all’elettropompa asincrona trifase configurata a
triangolo () 230Vac
- Connettere il cavo di ingresso ai tre fili (fase,neutro,
terra) alla rete monofase a 230Vac tramite un
interruttore termico dimensionato in funzione dei dati di
targa dell’elettropompa.
Di seguito uno schema a titolo di esempio.
EN The device is provided with two terminals (line /
pump) accessible through a door with built-in cable
glands, which is connected to the device with screws.
Remove the door, exposing the terminal and passing the
cables in their cable glands:
- Connect the output cable (ground, triple-phase,
screen) to the three-phase pump with () triangle
configuration 230 Vac.
- Connect the input cable with three wires (phase,
neutral and ground) to the power supply through a
single-phase 230Vac circuit breaker sized in
function of the pump rating.
Hereafter an electrical link schema just for
example.
- Richiudere lo sportello facendo attenzione alla corretta
posizione dell’O-Ring. E’ necessario rispettare il verso
corretto di montaggio dell’O-Ring per evitare eventuali
infiltrazioni d’acqua.
- Dopo aver accostato in maniera uniforme lo sportello
all’O-ring, proseguire con il serraggio.
NB: Al fine di evitare possibili problemi di
condensa e per evitare eventuali infiltrazioni
d’acqua, è necessario avvitare a croce le viti di
chiusura utilizzando una coppia di serraggio
compresa tra 0.25÷0.35Nm, consigliato 0.30Nm.
(vedi la sequenza in figura).
-
- Close the door and ensure the correct position of
the O-Ring. To prevent any water infiltration is
necessary to respect the correct assembly of the
O-Ring.
- After having approached the door uniformly on the
O-ring, continue the tightening.
NB: To avoid condensation problems and to
prevent the possible water infiltration, you
need to tighten the screws using a torque
between 0.25 to 0.35Nm, recommended
0.30Nm.
(see the sequence in figure)
-

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
18
I . EPOWER è certificato:
EN60730 sicurezza
EN61000-6-4 emissioni elettromagnetiche industriali
EN61000-6-3 emissioni elettromagnetiche residenziali, con
il seguente cavo di uscita:
EN EPOWER is certified:
EN60730 safety
EN61000-6-4 EMC industrial environment.
EN61000-6-3 EMC residential environment, with the
following output cable:
Sezione cavo uscita - Section Output Cable
(Schermo a terra - Screen to GND)
I Sezione cavo in funzione della lunghezza.
EN Section power supply cable linked to cable length.
Tutte le parti interne all’inverter sono sotto rete
elettrica. In caso di contatto puo’ esserci pericolo di morte
Tutti i lavori di installazione e manutenzione devono
essere eseguiti da personale qualificato con l’uso di
strumentazione idonea! Il personale deve utilizzare idonei
dispositivi di protezione. In caso di guasto, scollegare o
spegnere l’alimentazione elettrica.
Prima di effettuare interventi di riparazione attendere
almeno 5 minuti per consentire al condensatore di scaricarsi.
Se non viene osservata questa precauzione, sussiste il
pericolo di folgorazione, ustione o morte.
Dispositivi di protezione
Contattare la società fornitrice dell’alimentazione elettrica per
informazioni sui dispositivi di protezione necessari.
Applicabile:
- messa a terra di protezione;
- dispositivi di protezione funzionanti con corrente CA e CC
residua (RCD);
- sistemi TN.
Messa a terra di protezione
- Data la presenza di condensatori nel filtro in ingresso, può
aversi corrente verso massa.
- Scegliere un’unità di protezione idonea in base alle
regolamentazioni locali.
Dispositivo a corrente residua (RCD/RCCB)
- Quando si utilizza un dispositivo a corrente residua (RCD),
accertarsi che intervenga anche in caso di corto circuito nella
parte CC del collegamento a massa dell’inverter!
=> utilizzare RCD sensibili a corrente ad impulsi.
- Installare il dispositivo a corrente residua in conformità con
le regolamentazioni locali!
Interruttore automatico
- Utilizzare un interruttore di circuito automatico con curva
caratteristica di tipo C.
- Per il dimensionamento della protezione di rete si rimanda
al Capitolo Dati tecnici.
In caso di utilizzo dell’inverter con gruppi elettrogeni
e/o UPS contattare MAC3.
All internal parts of the drive are unde power
supply. In case of contact may sussit risk of death.
All installation and maintenance work ,must be
performed by qualified staff using suitable instruments!
Staff must use suitable protective equipment.
In the event of a fault, disconnect or switch off the power
supply.
Before performing repairs on the drive wait at
least 5 minutes to allow the capacitor to discharge.
Danger of electrocution, burning or death if this
precaution is not observed.
Safety devices
Contact the electricity provider for information
concerning safety devices.
Applicable:
- safety earthing;
- safety devices operating with residue alternating and
direct current (RCD);
- TN systems.
Safety earthing
- Given the presence of condensers in the inlet filter,
current to mass may occur.
- Choose a suitable safety device according to local
regulations.
Residual current circuit breaker (RCD/RCCB)
- When a residual current circuit breaker (RCD) is used,
make sure it trips even if a short circuit occurs in the DC
part of the earth connection of drive!
=> use RCD's that are sensitive to pulse currents.
- Install the residue current circuit breaker according to
local bylaws!
Automatic switch
- Use an automatic circuit switch with a type-C
characteristic curve.
- Consult the Technical Specifications for the size of the
mains protection system.
In case the inverter was used with generators
and/or UPS, contact MAC3.

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
19
6.3 Suggerimenti - Tips
I Pompe sommerse:
In caso di utilizzo dell’inverter con pompe sommerse, si
suggerisce di impostare il par.21 con un valore pari a 30hz.
ENSubmersible pumps:
In case of use the inverter with submersed pumps, we
suggest to set par.21 with a value equal to 30hz.
7 Collegamenti aggiuntivi - Additional connections
I Sulle morsettiere interne è disponibile:
- Un ingresso per galleggiante di minima o controllo
remoto (se attivato Epower entra in standby)
- Un’uscita a relè per:
1. Pilotare una seconda pompa a velocità fissa
2. Attivare un allarme esterno (per anomalie di tipo
elettrico ed idraulico)
- Collegamento con altri dispositivi ePower (modalità
multipompa)
Lo sportellino è predisposto per la foratura e l’inserimento dei
pressacavi per i collegamenti aggiuntivi.
Le opzioni per abilitare le varie funzionalità sono selezionabili
nel menu esteso (“vedi Tabella Parametri”)
EN The internal terminals are provided of:
- Input for dry running floating or remote control. If this
input is enable, Epower is set in standby.
- Output relay:
1. To pilot a second pump at fixed rate
2. To activate an external alarm (for electrical and
hydraulic anomalies).
- Connection with other ePower (multipumps mode)
The terminal cover is designed for drilling and insertion
of the cable for the additional links.
To set these options enter in extended menu (see
“Parameter Table”)
7.1 Configurazione Galleggiante di minima - Dry running float Configuration
I E’ possibile utilizzare un galleggiante di minima per
permettere l’attivazione dell’inverter in funzione della
posizione del galleggiante.
Per abilitare tale funzione occorre:
- Collegare il galleggiante sulla morsettiera J11 (vedi
figura sopra)
- Abilitare la funzione “Abilita Remoto” dal menu esteso.
(vedi parametro 55 nella sezione Menù Esteso)
EN It’s possible to use a floatswitch for activation of
inverter.
To enable this function:
- Connect the floatswitch on the terminals J11 (see
picture above)
- Enable “remote control” function on extended menu
(par.55 paragraph Extended Menu)
7.2 Configurazione Relè - Relay Configuration
I E’ possibile utlizzare il relè presente nella scheda madre
(J10) come relè d’allarme (per anomalie di tipo elettrico ed
idraulico), di marcia o per pilotare una seconda pompa in
ON/OFF. Le funzioni possono essere abilitate dal menu
esteso (par.50).
EN It’s possible to use the relay (J10 ) on the mother
board as a warning signal (for electrical and hydraulic
anomalies), run pump, or to build boosting system with a
second pump at fixed rate.The functions can be enabled
by the extended menu (par.50).

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
20
7.3 Configurazione Booster (pompa ON/OFF) - Booster Configuration (ON/OFF pump)
I
Collegare il comando booster sul morsetto J10 tra “C” ed
“NO”.
impostare il parametro 50 : “Configuration.Relay” = “BO”
Impostare al parametro 51 “Inc Pres Booster” il valore di
incremento della pressione (default = 0,2bar). Questo
valore determina l’aumento della pressione di impianto
richiesto dopo l’avviamento della pompa ON/OFF.
Funzionamento Booster:
Modalità di accensione seconda pompa ON/OFF:
Ogni volta che la pressione di impianto non viene raggiunta e
la frequenza dell’inverter ha invece raggiunto la frequenza
massima di lavoro della pompa (es.50Hz/60Hz), viene
azionato il comando di avvio della pompa ON/OFF.
Con l’avviamento della seconda pompa viene incrementata
la pressione impianto di un valore pari a quello impostato al
parametro 51 “Inc Pres Booster” (default 0,2 bar). Questo
parametro determina l’aumento della pressione di impianto
per evitare pendolamenti. In caso di necessità può essere
aumentato fino ad un massimo di 1,5bar (default = 0,2bar).
Modalità di spegnimento seconda pompa ON/OFF:
Il parametro che determina la disattivazione del comando
verso la seconda pompa è:
-parametro 64 “Soglia Minima”. (default = 50%)
Quando la percentuale di potenza erogata dall’inverter è
inferiore alla soglia minima (par.64) e la pressione misurata è
superiore alla pressione di impianto, allora viene disattivato il
comando booster.
Es.
parametro 47 “Potenza Motore” = 1000 watt
parametro 64 “Soglia Minima” = 50%
parametro 72 “Press.Impianto” = 2.5 bar
Considerando i dati sopra riportati, la potenza per la
disattivazione del comando e’ pari al 50% di 1000 watt
quindi: 500 watt.
Se la pressione misurata e’ maggiore o uguale a 2,5bar e la
potenza misurata è inferiore a 500 watt viene disattivato il
comando booster.
N.B. Il funzionamento Booster è attivo solamente
quando il modo operativo dell’inverter è
AUTOMATICO (vedi parametro 28 nella sezione
Menù Esteso)
EN
Connect the control of booster on J10 between “C” and
“NO”.
Set parameter 50 : ”Configuration Relay” = “BO”
Set the parameter 51 “Inc Pres Booster” the value of
pressure rise (default = 0.2 bar). This value determines
the increase of the system pressure required after the
starting of the pump ON / OFF.
Booster Operation:
How to start second pump ON / OFF:
If the first pump cannot reach pressure system and the
frequency is at the maximum working value
(es.50Hz/60Hz), the drive switch on the command to
start the second pump ON / OFF.
As soon the second pump is started, the drive increase
the system pressure value by an amount equal to the
parameter 51 “Inc Pres Booster” (default 0.2bar [2.9psi]).
This parameter determines the increase of the system
pressure to avoid oscillation. In case of need can be
increased up to a maximum of 1.5 bar [21.75 psi]
(default = 0.2 bar [2.9psi]).
How to stop the second pump ON / OFF:
The parameter that switches off the control for the
second pump is:
-parameter 64 “MinTresholdPar”. (Default = 50%)
When the percentage of power is lower than the
threshold and the measured pressure is higher than the
system pressure, then the drive switches off the second
pump.
Eg.
Parameter 47 “Motor Power” = 1000 watts
parameter 64 “MinTresholdPar” = 50%
parameter 72 “System Pressure” = 2.5 bar [36.26 psi]
The power value to switch off the second pump is equal
to 50% of 1000 watts then: 500 watts. So that if pressure
is greater or equal to 2.5 bar [36.26 psi] and power is
less than 500 watt the drive switch off the second pump
N.B. The Booster operation is only active
when the operating mode of the inverter is
AUTOMATIC (see parameter 28 in the
Extended Menu)

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
21
I Esempio di collegamento per Modalità Booster (pompa
ON/OFF – versione MM/MT)
EN Connection example for Mode Booster
(pump ON / OFF – MM/MT version)
IIn caso di manutenzione dell’inverter
può essere connesso un pressostato
ausiliario che permette di garantire
continuità di servizio all’impianto per
mezzo della pompa on-off.
Si consiglia di prevedere in tal caso
l’uso di un vaso d’espansione
correttamente dimensionato.
Attenzione il pressostato ausiliario
non deve essere connesso
quando si usa l’inverter.
ENIn case of maintenance of the
inverter, an auxiliary pressure
switch can be connected to
guarantee continuity of service to
the system with the on-off pump.
It is advisable to provide in this
case the use of an expansion
tank correctly dimensioned.
Beware the auxiliary switch
should not be connected when
the inverter.

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
22
IIn caso di manutenzione dell’inverter
può essere connesso un pressostato
ausiliario che permette di garantire
continuità di servizio all’impianto per
mezzo della pompa on-off.
Si consiglia di prevedere in tal caso
l’uso di un vaso d’espansione
correttamente dimensionato.
Attenzione il pressostato ausiliario
non deve essere connesso
quando si usa l’inverter.
EN In case of maintenance of
the inverter, an auxiliary
pressure switch can be
connected to guarantee
continuity of service to the
system with the on-off pump.
It is advisable to provide in this
case the use of an expansion
tank correctly dimensioned.
Beware the auxiliary switch
should not be connected when
the inverter.

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
23
7.4 Configurazione modalità Multipompa - Multipump Configuration
I E’ possibile installare ePower in configurazione multipompa
(solo modello ADVANCED) composta da un inverter Master
che pilota fino ad un massimo di 7 inverter Slave. L’inverter
Master determina il funzionamento degli inverter Slave.
Per abilitare la modalità multipumpa occorre:
- Togliere il coperchio ed aprire uno dei fori posizionati nella
zona di preforatura. Applicare un pressacavo di dimensioni
adeguate al tipo di cavo utilizzato per il collegamento tra le
varie unità ed effettuare il collegamento utilizzando la
morsettiera J20 come in ”Esempio di collegamento in
modalità Multipompa”
- Impostare dal menu esteso il parametro 28 “Prossimo
OpMode” con il valore “MP”: Multipompa.
- Impostare dal menu esteso il parametro 4 “Config. Rete
ID” con un numero compreso tra 0 e 7. L’inverter con il
valore numerico piu’ basso rappresenta il Master del
gruppo.
- Impostare il parametro 47 “Potenza Nominale“ con il valore
di potenza nominale della pompa (P1).
(vedi parametro 47 nella sezione Menù Esteso). Nel caso
in cui sulla targa della pompa venga riportato solamente la
potenza utile P2, inserire come potenza nominale il valore
dato da P2/0.7. Per entrambi i valori di potenza (P1 e P2)
l’unità di misura è espressa in Watt.
- Dopo essere usciti dal menu esteso il display visualizza
per l’unità Master “MA” mentre per le unità Slave
visualizza “Ux” (dove x è il numero attribuito all’inverter con
il parametro 4).
Esempio di collegamento in modalità Multipompa:
EN It’s possible to connect ePower in multipumps
configuration (ADVANCED model only) composed from
an inverter Master that can drive 7 inverter Slave.
To enable mutipump mode is needed:
- Remove the lid and open one of the holes located in
the area of pre-drilling. Apply a cable gland of
adequate size for the type of cable used for the
connection between Master and Slave and connect
them using the terminals J20 see “Connection
between Master/Slave”.
- Set the parameter 28 “Next OpMpde” with the value
“MP”: Multipump.
- Set the parameter 4 “Net Config ID” with a number
between 0 and 7. The inverter with lowest numerical
value is the Master of the group.
- Set the parameter N. 47 “Motor Power” with the
nominal power value of the pump (P1). (See
parameter 47 in Extended Menu section). If in the
pump is shown only the useful power P2, the
nominal power is given by P2/0.7. For both the
power values (P1 and P2), the unit of measurement
is expressed in watts.
- After exiting from extended menu, the Master unit
displays "MA", while the Slave unit displays "Ux"
(where x is the number assigned to the inverter with
parameter 4).
Connection between Master/Slave:

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
24

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
25
N.B. E’ possibile utilizzare un solo galleggiante di
minima per il controllo di un gruppo nella
modalità multipompe:
N.B. It’s possible to use only one floatswitch
to control the multipump group:

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
26
8 Menu software - Software Menu
I Con i tasti + e – è possibile selezionare il parametro
desiderato, fra quelli riportati in tabella, e leggerne il valore.
Per modificare il parametro selezionato premere per 5
secondi il tasto SAVE/DISPLAY, fino a che il led diventa
rosso. Modificare il valore del parametro con i tasti + e –.
Salvare il valore premendo, per 5 secondi, il tasto
SAVE/DISPLAY. Si consiglia di consultare anche il
paragrafo successivo per la ricerca guasti
EN Use the + and – to select the desired parameter,
among those listed in the table, and read its value.
To change the selected parameter, press the
SAVE/DISPLAY button for 5 seconds, until the LED
turns red. Change the value of the parameter using the +
and -.
Save the value by pressing for 5 seconds, the button
SAVE/DISPLAY. You should consult also the next
section for troubleshooting.
Visualizza la pressione presente in impianto.
Imposta la pressione d’impianto desiderata *
Displays the in pipe pressure.
Sets the required system pressure
Visualizza la pressione di ripartenza
Imposta la pressione di ripartenza desiderata
Displays the restart pressure.
Sets the required restart pressure
Visualizza la frequenza a cui gira la pompa
Valore massimo impostato per la frequenza (non
modificabile in questo menu)
Displays the instant pump frequency.
Max value set for the frequency (not
changeable in this menu)
Visualizza la corrente assorbita dalla pompa.
Imposta il massimo valore rms della corrente di fase
Displays the current absorbed by the
pump.
Set the max rms value of the phase current
* La pressione di ripartenza è calcolata da Epower.
Press. Restart = Press. Impianto x 0.8.
Per modificarla impostare il nuovo valore dopo avere
impostato la pressione d’impianto
The restart pressure is calculated from Epower.
Press. Restart = Press. System x 0.8.
To change it, please set the new value after setting the
system pressure.
9 Ricerca Guasti e Manutenzione - Troubleshooting & Maintenance
I IL’Epower garantisce la protezione della pompa da ogni
tipo di anomalia comune e per salvaguardare la fornitura
idrica effettua tentativi di ripristino automatici. Nella colonna
Code vengono riportati i messaggi sul tipo di funzionamento
ed i codici di errore che identificano il tipo di anomalia in
corso.
EN The Epower provides pump protection from any type of
common problems and to safeguard the water supply the
drive attempts automatic restarts.
The display shows messages and error code to identify the
type of fault .
Significato del
Messaggio
Rilevato un corto tra
fase e fase sulla
pompa.
5 tentativi di riarmo
e dopo blocco
permanente.
Rimuovere le cause del
corto.
Verificare il corretto
assorbimento del motore.
Togliere l’alimentazione
Attendere che il display si
spenga
Ripristinare
l’alimentazione
Phase-Phase or
Phase-Ground
short circuit
found.
5 Automatic
restarts and then
a permanent
locked status
Remove the short circuit.
Check the correct motor
absorption.
Disconnect the power
supply.
Wait for the display to
switch off.
Restore the power supply.
Rilevata corrente
eccessiva nella
pompa
Verificare la misura della
corrente al parametro 36
“Corrente di Uscita” e
impostare il valore
massimo di corrente al
param. 49
“MaxCorr.Motore”.
Verificare che la pompa
venga utilizzata nelle
condizioni prescritte dal
suo costruttore
Assicurarsi che non vi
siano condizioni di attrito
o di blocco della girante
Over current
detected in the
pump
Check current
measurement output at
parameter 36
“LoadCurrent “ and set the
proper value of max.
current at parameter 49.
Verify that the pump is
used under the conditions
prescribed by its
manufacturer
Make sure that there are
no conditions of friction or
locking of the impeller

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
27
Tensione
bassa..
Low Voltage
Rilevata tensione di
alimentazione
troppo bassa
(inferiore a 170 Vac)
Il riarmo è
automatico quando
la tensione di
alimentazione
ritorna ai valori
corretti.
Controllare l’impianto
elettrico e ripristinare i
valori nel range prescritto
per EPOWER
Power voltage
measured is too
low (less than
170 Vac).
The reset is
automatic when
the voltage
returns to the
correct values
Check the electric system
and reset the values to
within the range prescribed
for the EPOWER
Tensione alta
High voltage
E’ stata rilevata una
tensione di
alimentazione
troppo alta
(maggiore di
270Vac). Il riarmo è
automatico quando
la tensione di
alimentazione
ritorna ai valori
corretti.
Controllare l’impianto
elettrico e ripristinare i
valori nel range prescritto
per EPOWER.
Verificare eventuale
presenza aria in pompa e
in caso eliminarla.
Power voltage
measured is too
high (over 270
Vac).
The reset is
automatic when
the voltage
returns to the
correct value
Check the wiring system
and set the values in the
range prescribed for the
EPOWER.
Check for the presence of
air inside the pump and if
necessary eliminate it.
Temp. Interna >75
°C.
Riarmo automatico
se Temp.< 60 °C.
Verificare che la
temperatura dell’acqua in
ingresso rientri nelle
specifiche di prodotto.
Verificare e ripristinare il
corretto adescamento
della pompa
Water Temp>75
°C.
Automatic reset if
Temp.< 60 °C:
Check water temperature
is within the values
indicated in the product
specifications.
Check and restore the
correct pump priming
action.
Blocco
Cortoc.
Short
Circ.Block
L’inverter è in blocco
dopo aver effettuato
10 tentativi di riarmo
a seguito di
cortocircuito tra
fase-fase sulla
elettropompa.
Per rimuovere il blocco è
necessario portare a zero
il numero dei corti
accumulati al parametro
65 del menù esteso
“Tot.CortoC.Fatti”
Se il problema persiste
tentare il riarmo
scollegando la pomp..
The drive is in
lock status after
10 reset attempts
made following
short circuit
between phase
and phase and
phase-earth on
the electro-pump.
To remove lock status set
to zero the number of
shortcircuit parameter 65
“Tot.ShortC.Done “
If the problem persists try
to reset the drive
unplugging the pump .
Protetto per
I2t
I2t protected
L’inverter ha
misurato una
corrente eccessiva.
Verificare che la pompa
venga utilizzata nelle
condizioni prescritte dal
suo costruttore
Assicurarsi che non vi
siano condizioni di attrito
o di blocco della girante
The drive has
measured an
excessive
current.
Verify that the pump is
used under the conditions
prescribed by its
manufacturer
Make sure that there are
no conditions of friction or
locking of the impeller
Motore
Sconnesso
Motor
Unconnected
La pompa non è
collegata all’inverter
Controllare che il cavo di
uscita dall’inverter sia
collegata alla pompa
The pump isn’t
connected to the
inverter
Check that the
power output cable from
the inverter is connected to
the pump
Rilevata mancanza
acqua.
L’inverter tenta il
riarmo per 5 volte.
Se falliti, il sistema
rimane in blocco.
Il ripristino viene
tentato di nuovo
ogni 50 minuti per
24 volte. Dopodiché
il sistema rimane in
blocco permanente
Verificare presenza
acqua:
Ripristinare il corretto
adescamento della
pompa
Controllare che il filtro non
sia ostruito
Togliere l’alimentazione
Attendere che il display si
spenga
Ripristinare
l’alimentazione
Lack of water
found
Automatic reset
set in factory for
5 reset attempts
every 5 minutes;
if unsuccessful
the reset is again
attempted every
50 minutes for 24
times. After
which the system
remains in a
state of
permanent
blockage.
Check for water presence.
Reset the correct pump
priming function.
Check that the filter is not
blocked.
Disconnect the power
supply.
Wait for the display to
switch off
Re-connect power supply.

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
28
Press. Insuff
Insuff. Pres
La pressione
misurata e’ al di
sotto della pressione
minima impostata
(default 0.8bar).
L’inverter tenta il
riarmo per 5 volte.
Se falliti, il sistema
rimane in blocco.
Il ripristino viene
tentato di nuovo
ogni 50 minuti per
24 volte. Dopodiché
il sistema rimane in
blocco permanente.
Verificare che non ci sia
una grossa perdita
nell’impianto
Verificare il corretto
dimensionamento
dell’elettropompa
Eliminate le cause
togliere l’alimentazione
Attendere che il display si
spenga
Ripristinare
l’alimentazione
The pressure
measured is
under the minum
set value (default
0,8 bar).
Automatic reset
set in the factory
for 1 reset
attempt every 5
minutes if
unsuccessful the
reset operation is
attempted again
every 50 minutes
for 24 times.
After which the
system is
permanently
blocked
Check that there is no
major leakage on the
system
Check the correct
dimensions of the electropump
On eliminating the causes
disconnect the power
supply
Wait for the display to
switch off
Restore power supply.
Fault Sens.
Press
Press Sensor
Fault
Rilevato un guasto
nel sensore di
pressione
Detected a fault
in the pressure
sensor
Contact after selling
service
Colpo di
Ariete
Water
Hammer
Il sistema ha rilevato
un superamento di
oltre 2 volte la
pressione
impostata. Il riarmo
e’ automatico.
Il drive va in blocco
se si supera i 5
tentativi di riarmo.
Verificare il corretto
funzionamento del vaso
d’espansione.
The system
detected an
overrun of more
than 2 times the
pressure set. The
reset is
automatic.
The drive is
blocked if the
number of
automatic
restarts is over 5.
Verify the correct
functioning of expansion
tank.
Protezione
Pompa
Pump
Protection
La pompa è rimasta
accesa
continuamente per il
tempo impostato al
parametro 40
-Controllare eventuali
perdite nell’impianto
The pump has
been in operation
continuously for
the time set in
parameter 40
-Check the leaks of the
system
L’inverter è
configurato come
Master
Il messaggio “MA” è
visualizzato quando
l’inverter è utilizzato in
modalità Multipompe
The inverter is
configured like
Master
The message "MA" is
displayed when the
inverter is used in
multipump mode.
L’inverter è
configurato come
Slave
The inverter is
configured like
Slave
Nella modalità
Multipompa viene
utilizzato il
protocollo di
comunicazione
CANBUS. Il display
visualizza “CB”
quando è in corso lo
scambio dei dati tra
gli inverter che
compongono il
gruppo.
Multipump mode
uses CANBUS
communication
protocol . The
display shows
"CB" when a
data exchange is
present between
the inverters in a
group.

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
29
Errore di
Identificazione
ID Error
Nella modalità
Multipompa viene
assegnato
dall’utente un valore
numerico (ID) che
identifica l’inverter in
un gruppo. Il
messaggio indica
che nel gruppo sono
presenti inverter con
lo stesso
identificativo
numerico.
Per rimuovere l’errore è
necessario modificare dal
menu esteso, il parametro
4 “Config. Rete ID” ed
assegnare all’inverter un
nuovo valore numerico
compreso tra 0 e 7.
In Multipump
mode the user
assigns a
numerical value
(ID) that
identifies the
inverter in a
group. The
message
indicates that in
the group are
inverters with the
same numerical
identifier.
To remove the error you
need to change from
extended menu, parameter
4 "Net Config.ID" and
assign to inverter a new
numeric value between 0
and 7.
Identifica l’unità
slave nella modalità
multipompe. “x” è il
valore numerico
assegnato allo slave
dal parametro 4
“Config. Rete ID”
Identifies the
slave unit in
multipump mode.
"x" is the
numerical value
assigned to the
slave in
parameter 4 "Net
Config. ID "
Fuori servizio
Out of service
Il messaggio viene
visualizzato nella
modalità
Multipompe.
L’inverter del gruppo
che si trova in
questo stato ha
esaurito i riarmi
automatici da
anomalie
Individuare la causa
dell’anomalia e riavviare
l’inverter
The message is
displayed in
multipump mode.
The inverter
finished the
automatic
restarts.
Find the cause of the fault
and restart the inverter

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
30
10 Menu Esteso - Extended Menu
I Il menu esteso permette la visualizzazione di tutti i
parametri. Per accedere alla lista parametri tenere premuti
contemporaneamente i tasti: + e - per alcuni secondi
Compare la scritta EX alternata al numero del parametro.
EN The extended menu permits the visualization of all
parameters. To access to the parameter list keep the
keys: + and - , pressed simultaneously for a few
seconds. Displayed the initial EX and the parameter
number.
Con i tasti + e – si seleziona il parametro desiderato.
Per visualizzare il valore del parametro premere il tasto
SAVE/DISPLAY.
Es. scelta del parametro massima frequenza.
Use the key + and - to select the desired parameter.
To view the parameter value press the SAVE / DISPLAY
key.
Eg choice of the parameter maximum frequency.
Per la modifica del parametro premere il tasto
SAVE/DISPLAY fino a che non si illuminano tutti i led.
Con il tasto + e – variare il valore del parametro.
Es. portare a 60Hz il valore massimo.
To modify the parameter press the key SAVE / DISPLAY
until all the LEDs light up.
With the key + and - change the parameter value.
Eg lead to 60Hz, the maximum value.
Per salvare il nuovo valore premere di nuovo il tasto
SAVE/DISPLAY fino a che non compare EX e si spengono i
led; si ritorna all’elenco parametri.
To save the new value press the key SAVE / DISPLAY
until it appears EX and the leds are off; you are back to
the parameter list.
Per uscire dal menù esteso premere contemporaneamente:
+ , - fino a che la scritta EX è visualizzata sul per alcuni
secondi; le modifiche verranno salvate in memoria.
Per uscire senza salvare il nuovo valore premere il tasto
ON/OFF: le modifiche effettuate non saranno memorizzate
e saranno perse con lo spegnimento del dispositivo.
Visualizzazione del valore dei parametri a più di 2 cifre.
Valori a 4 cifre: si presentano alternativamente le due cifre
più significative (evidenziate dalla presenza del punto a
destra sul display) e le 2 cifre meno significative.
Es 1234
To exit the extended menu simultaneously press the
keys +and -, until the EX is written on the display for a
few seconds; so that the changes will be saved in
memory.
To exit without saving the new value press the ON / OFF:
the changes made will not be saved and will be lost with
the shutdown of the device.
Value display for parameters of over 2 digits.
4-digit values: displayed alternate of the two most
significant digits (indicated by the presence of the right
point on the display) and the 2 least significant digits.
Eg 1234
Valori a 3 cifre: si presentano alternativamente la cifra più
significativa (evidenziate dalla presenza del punto a destra
sul display) e le 2 cifre meno significative. Es 234
3-digit values: displayed alternate of the most significant
digit (indicated by the presence of the right point on the
display) and the 2 least significant digits. Eg 1234

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
31
Visualizzazione di numeri negativi: si presentano
alternativamente il segno – e il valore numerico.
Es -0.3
Display of negative numbers displayed alternate of the
sign - and the numeric value.
Eg -0.3
Per la modifica del valore dei parametri a più di 2 cifre si
agisce come nel caso di parametri a 2 cifre ma durante la
pressione del tasto + o del tasto – si visualizzano solo le 2
cifre meno significative.
To change the value for parameters over 2-digits act as
in the case of parameters to 2-digits, but when pressing
the + or - button will display only the 2 least significant
digits.

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
32
10.1 Tabella Parametri - Parameter Table
Frequenza massima di uscita del drive.
Maximum frequency of drive
output
Indica la frequenza alla quale si applica
la massima tensione sul motore
Sets the applicable frequency
on the motor to obtain Vmax
Imposta l’identificativo numerico agli
inverter che compongono un gruppo. La
configurazione del parametro è
necessaria solo nella modalità
Multipompa
Sets numerical identifier to the
inverters of the group. The
parameter is used only in
multipump mode.
Imposta il tempo di accelerazione per
passare da frequenza nulla a frequenza
massima applicata al motore
Sets the acceleration time to
move from null to maximum
frequency applied to the motor
Imposta il tempo di decelerazione per
passare da frequenza massima a
frequenza nulla applicata al motore
Sets the deceleration time to go
from maximum to null
frequency applied to the motor
Imposta la frequenza che si applica al
motore (Opmode=Manuale)
Sets the frequency applied to
the motor (OpMode=manual)
Imposta l’unita’ di misura
Visualizza il numero di restart fatti del
drive
Displays restarts number
undertaken
-Imposta la massima pressione per far
intervenire l’allarme “colpo d’ariete”
-Impostare “NO” per disabilitare la
protezione
-Sets the maximum pressure to
activate the alarm “Shock
Pressure”
-Sets “NO” to disable protection
Contatore del numero di riavvii eseguiti
per allarmi idraulici.(es. manca acqua,
pressione insufficiente).
Displays the number of restarts
undertaken for hydraulic alarms
(i.e. dry running, Insuff.
Pressure)
Durata della perturbazione
Time length for perturbation
Contatore del numero di volte in cui la
pressione misurata supera almeno del
doppio la pressione impostata
Counter events when the
measured pressure is found to
be double that of the pressure
setpoint
Frequenza minima di avvio e di stop del
motore
Minimal frequency applied to
the motor
Pressione minima di impianto, al di
sotto della quale viene segnalata
anomalia (“pressione insufficiente”.
Cod. errore 11).
Minimum system pressure,
under which an anomaly state
is indicated (“Insufficient
pressure”. Error code 11).
Abilita/Disabilita la funzione
antigrippaggio
Enable/Disable the anti-lock
function
Coefficiente proporzionale del
regolatore PID
Proportional coefficient of the
PID regulator
Coefficiente integrale del regolatore PID
Integral coefficient of the PID
regulator
Imposta il modo operativo dell’inverter
(MA: manuale, AU: automatico, MP:
multipompe)
Sets the operational mode of
the drive (MA: manual, AU:
automatic, MP: multipump)
Modo operativo attuale dell’inverter
Autoclave operational mode
Il parametro contiene 3 preset dei
parametri: PID KP,PID KI, Divisore
TPID, DurataPerturbazione, secondo la
tipologia di impianto:
“SL”=Lento,
”NO”=Normale,
”FA”=Veloce
The parameter contains 3
presets of the parameters: PID
KP, KI PID, Divisor T.PID,
Perturb. Length, according to
the type of plant:
“SL”=Slow,
”NO”= Normal,
”FA”= Fast
Lettura sensore di
pressione
Frequenza letta dal sensore di
pressione
Pressure sensor frequency
32
Offset del sensore di pressione (settare
Offset pressure sensor (to set

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
33
pressione ambiente =0 bar)
ambient pressure = 0 bar)
Taratura del fondo scala della lettura di
pressione.
Calibration of full-scale
pressure reading.
Pressione di impianto misurata
System pressure measured.
Tensione di alimentazione di EPOWER
Corrente di fase del motore
Temperatura misurata sul modulo di
potenza
Temperature measured on the
power module
Imposta il tempo massimo (in minuti)
continuo di accensione della pompa.
Trascorso il tempo impostato verrà
visualizzato l’allarme “Protezione
Pompa” E’possibile escludere la
protezione impostando “NO”
Sets the maximum time (in
minutes) of continuous power
of the pump. After the time
passed will be display the
message "Pump Protection".
It’s possible to disable the
protection setting “NO”.
Tempo per entrare in stato “pressione
insufficiente”.
Time for entry in
“insuff.pressure” state
Tempo per entrare in stato “Manca
acqua”
Time for entry into “No water”
state
Intervallo di perturbazione quando
pressione e frequenza sono costanti
Range and frequency of
disturbance when pressure is
constant
Rallenta la velocita’ di reazione del
sistema alle variazioni di pressione: da
utilizzare quando il sistema e’ instabile
(es. oscillazioni di pressione continue)
It slows down the speed of
system response to changes in
pressure: to use when the
system is unstable (eg,
continuous pressure
oscillations)
Frequenza applicata al motore
Frequency applied to the motor
Imposta la potenza nominale del
motore P1
Set the Power of the motor P1
Visualizza la potenza assorbita dalla
pompa (P1)
Power absorbed by the pump
(P1)
Massimo valore della corrente di fase
del motore.
Maximum rms value of motor
phase current
Scelta della funzionalità per il relay:
AL= Allarme (per anomalie di tipo
elettrico ed idraulico),
RU=Marcia,BO=Booster, RA=Remote
Alarm
Choosing the function for the
relay: AL=Alarm (for electrical
and hydraulic anomalies),
RU=Run,
BO=Booster, RA=Remote
Alarm
Incremento Pressione
Booster
Incremento della pressione impianto
quando il booster è attivo (default 0.2
bar)
Pressure Increment
Booster
Pressure increment when
booster is ON (default 0,2 bar)
Imposta la corrente massima di picco
rilevabile allo spunto, superata la quale
scatta la protezione: "Protetto per I2t"
Sets the maximum peak
current detected at start up,
after which the protection
snaps: "I2t protected"
Se ON il drive è in standby e aspetta un
comando esterno per partire
(galleggiante).
If ON,the inverter is in
STANDBY and wait external
command to start (float switch)
Active pumps in booster config.
Frequenza di stop del motore
Stop frequency of the pump
Variazione della curva di pilotaggio
della pompa da lineare (0) a quadratica
(1÷99)
Variation of the driving pump
curve from linear (0) to
quadratic (1÷99)
Soglia in % della potenza assorbita
sotto la quale viene spenta la seconda
pompa nella modalità multipompa
Deactivation threshold (%) of
the second pump in multipump
mode.
Contatore di cortocircuiti fase-fase.
Short circuit counter of either
phase-phase
Imposta la pressione d’impianto
desiderata
Sets the required system
pressure

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
34
Imposta la pressione di riavvio
dell’inverter.
Sets the drive restart pressure
Determina il senso di rotazione
dell’elettropompa (solo versione MT)
Determines the rotation sense
of the electro-pump (only MT
version)
Visualizza la versione software
utilizzata
Displays the software release
used
Ripristina la configurazione di fabbrica
Restore factory configuration
Massima potenza assorbita dalla
pompa in assenza di flusso
Max power absorbed without
flow
Parametro che permette di visualizzare
lo stato del modulo Wifi utilizzato con
l’inverter.
Selezionare il valore “Access Pnt” per
riavviare la procedura di configurazione
del modulo wifi.
Parameter that displays the
status of Wifi module used with
the inverter.
Select the value "Access Pnt"
to restart the configuration of
the module wifi.
Se la funzione “Abilita Remoto” è attiva,
il parametro permette di impostare un
tempo di ritardo dal momento in cui il
galleggiante remoto riattiva l’inverter
dallo stand-by. (Il tempo visualizzato è
espresso in secondi).
If "Remote Enable " is active,
the parameter allows to set a
delay time when the floatswitch activates the inverter
from the stand-by. (The time is
in seconds)
Se la pompa è ancora attiva dopo che è
trascorso il tempo impostato, l’inverter
forza lo scambio pompe (funzione
abilitata solo in modalità “Multipompe”).
(Il tempo visualizzato è espresso in
ore).
If the pump is still active after
the set time has elapsed, the
inverter force the exchange
pumps (function enabled only
in "multipumps mode"). (The
time is in hours)
Accende o spenge la pompa
Switches the pump on or off
* le cifre sono 3 nel caso si stia visualizzando la pressione in PSI
* The digit are 3 if the pressure is PSI

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
35
11 DICHIARAZIONE DI CONFORMITÀ- CONFORMITY DECLARATION
Apparato - Appliance: EPOWER
Costruttore - Manufacturer: MAC 3 S.p.A.
Via Maestri del lavoro, 25
50013 Campi Bisenzio (FI) Italia
Il costruttore dichiara sotto la propria responsabilità che il prodotto specificato è conforme alle normative sotto riportate e
soddisfa i requisiti essenziali richiesti dalle Direttive:
2014/35/UE (Materiale elettrico destinato ad essere utilizzato entro taluni limiti di tensione)
The manufacturer hereby declares under its own responsibility that the specified product is in compliance with the
standards indicated above and that it meets the essential requisites of Directive:
2014/35/EU (Electrical equipment designed for use within certain voltage limits)
Norma Applicata - APPLIED STANDARDS
Safety (General Requirements)
CEI EN 60335-1:2008+ /A13:2009 + /EC:2010 + /A14:2012 +
/A15:2012
2014/30/UE (Compatibilità elettromagnetica - EMC)
Norme Applicate - APPLIED STANDARDS
Radiated Emissions: Disturbance Power
CEI EN 55014-1:2008 + /A1:2010 + /A2:2012
CEI EN 61000-6-4:2007+ /A1:2013
CEI EN 55014-1:2008 + /A1:2010 + /A2:2012
CEI EN 61000-6-4:2007+ /A1:2013
Radio Frequency Electromagnetic Fields
CEI EN 55014-2:1998 + /A1:2002 + /IS1:2007 +/A2:2009
CEI EN 61000-6-2:2006
Radio Frequency common mode
CEI EN 55014-2:1998 + /A1:2002 + /IS1:2007 /A2:2009
CEI EN 61000-6-2:2006
Fast transients (EFT-Bursts)
CEI EN 55014-2:1998 + /A1:2002 + /IS1:2007 +/A2:2009
CEI EN 61000-6-2:2006
Electrostatic discharges (ESD)
CEI EN 55014-2:1998 + /A1:2002 + /IS1:2007 /A2:2009
CEI EN 61000-6-2:2006
CEI EN 55014-2:1998 + /A1:2002 + /IS1:2007 +/A2:2009
CEI EN 61000-6-2:2006
Voltage dips and interruptions
CEI EN 55014-2:1998 + /A1:2002 + /IS1:2007 /A2:2009
CEI EN 61000-6-2:2006
Campi Bisenzio, 14 novembre 2017
Responsible party: MIRIAN RONCHI (Chairman):

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
36

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
37

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
38

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
39

Istruzioni-epower-26072018 (Cod.620030200 Rev. 10) ItaEng.doc
40
Via Maestri del Lavoro 25/27
50013 - Campi Bisenzio (FI) ITALY
Tel. +39.055.88.77.672 - +39.055.88.77.372
+39.055.88.79.276 Fax. +39.055.88.77.068