Product Specifications
17
Name and Model Number MABIS SmartSpeed®Plus Automatic Digital
Blood Pressure Monitor, 04-186-001, 04-186-006
Display System Digital display/LCD
Measuring Method Oscillometric
Power Source 4 AA batteries
Measuring Range Pressure: 20 to 280 mmHg
Pulse: 40-180 beats/minute
Accuracy Pressure: ±3 mmHg
Pulse: ±5% of reading
Pressurization Automatic pressurization by pump
Deflation Automatic pressure release valve
Memory Two built-in memory banks enabling display of up to
50 measurements each plus average of three most
recent measurements
Automatic Power Off Approximately 1 minute after last button operation
Battery Life Approximately 150 measurements
Operation
Temperature 50°F – 104°F (10°C – 40°C)
Humidity 40% to 85% RH (non-condensing)
Storage
Temperature
14°F – 140°F (-10°C – 60°C)
Humidity 10% to 95% RH (non-condensing)
Weight 14.1 oz. (without batteries)
Dimensions 5-7/8” x 3-3/4” x 3”
Arm Circumference Range Adult size fits arm circumference:
8-5/8” – 12-5/8” (22-32 cm)
Large adult size fits arm circumference:
12-5/8” – 16-1/2” (32-42 cm)
Accessories Cuff, nylon storage case, detailed guidebook, four
AA batteries, Quick Start Guides
Options (sold separately) Adult size cuff, Large Adult size cuff, Wide-Range
TM
cuff fits arm circumference 8-5/8” – 18” (22-46 cm)
AC adapter
Specifications are subject to change without notice.
16
Troubleshooting
If any abnormality occurs during use, please check and correct the
following:
Condition Correction
Display is blank when power is on. Check and correct the polarity of
the installed batteries. Reinstall or
replace batteries.
Measurement incomplete or Review and follow ‘Applying Your
abnormally low or high values Blood Pressure Cuff’ and ‘Taking
displayed. Your Blood Pressure Reading’
sections. Replace the batteries.
Measurements are different from Remember, blood pressure
those typically measured by readings are influenced by physical
physician or every measurement and mental conditions and/or even
reading is different. the time of day. Daily measurement
recordings should be interpreted
by your physician.
Care and Maintenance
1. Disconnect the cuff tubing from the monitor prior to storing.
2. Only use a soft, dry cloth to clean your blood pressure monitor.
3. Avoid using any types of liquids on the monitor or cuff.
4. Do not store the unit where it will be exposed to direct sunlight, dust or
humidity.
5. Avoid extreme temperatures.
6. Never disassemble the monitor or cuff.
7. Dropping or subjecting your blood pressure monitor to strong shocks
should be avoided.