MIX TURBO – Cooker hood
OPERATION MANUAL
Specifications
Extraction rate 420m3/h
Rated voltage 230V-50Hz
Power consumption 160 W
Light bulbs 2x25W (MAX 2x25W)
Air outlet 90mmx90mm
General safety and installation conditions:
When installing the applianc e, follow the conditions and guidelines given in this op erating manual.
This appliance is intended f or domestic use only. In cas e of commercial use in f ood business, warranty
conditions change.
Do not remove the plug fr om the power socket by pulling t he cord.
The power cord must not touch any hot surface.
Do not turn the appliance on if the power cord is damag ed.
The cooker hood, if used to extract cooking fumes outsi de, should be connected to an appropriate
ventilation duct (do not c onnect it to flues, smoke or exhaus t ducts which are in us e).
The manufacturer assumes no responsibility for any d amage caused by the installation not conforming
to the operating manual.
Any changes made in th e structure of the hood by unauth orized persons will result in the exclusion
of the liability of the manuf acturer.
If the cooker hood is used simultaneously with devices burn ing gas or other fuels, the room should be
appropriately ventilated (n ot applicable in the case of clos ed circulating system).
Do not use naked flame directl y under the cooker hood,
If the non-detachable power c ord is damaged, it should be r eplaced with a special cord a vailable
from the manufacturer or a specializ ed repair shop.
The exhaust air from the hood must not be discharged int o a flue used for discharging exhaust fumes
from appliances burning g as or other fuels (not applic able in the case of closed circul ation system).
Before connecting the c ooker hood to the mains power su pply and checking its c orrect functioning,
always check if the power c ord is properly installed and h as not been pinched by th e hood during
installation.
Before cleaning, unplug the power cord.
Cleaning not carried out in acc ordance with the manual c onstitutes a fire hazard.
This appliance is not intend ed for use by persons (includi ng children) with reduc ed physical, sensory
or mental capabilities, or lack of experience and knowledg e of the appliance, unl ess they are given
supervision or instructions according to the operating m anual by persons responsibl e for their safety.
Purpose and operations
The hood is intended for operation in a suction mode, disc harging the fumes outside, or for operation
in a filter mode as a closed circ ulation system.
Installation
The minimum distance bet ween the surface on which dishes are placed on the heatin g appliance and
1the lowest part of the cooker hood should be no less than 45cm in the case of electric s toves and no
less than 65cm in the case of gas or dual electric/gas st oves. If the manual of the heatin g appliance
recommends a larger distanc e for installation of a cooker hood, you must comply with t hese instructions.
Installation of the hood and th e hood’s casing pipe is sh own in Figure S3. When inst alling the hood,
you should observe the gener al regulations on discharging air from the room. You sh ould take into
account the fact that the us e of spiral aluminium pipes red uces the efficiency of the h ood and increases
the noise level of the flowing air.