Lynx 5000 Series, R FR 5018 Reference Manual

LYNXTechnik AG
®
Broadcast Television Equipment
R FR 5018
Series 5000 2RU 19” Rack Frame with Fan Front Cover
Revision 1.0 – July 2015
Information in this document is subject to change without notice. No part of this document may be reproduced or
transmitted in any form or by any means, electronic or mechanical for any purpose, without express written permission of
LYNX Technik AG may have patents, patent applications, trademarks, copyrights or other intellectual property rights covering the subject matter in this document. Except as expressly written by LYNX Technik AG, the furnishing of this
document does not give you any license to patents, trademarks, copyrights or other intellectual property of LYNX Technik
LYNX Technik AG.
AG or any of its affiliates.
LYNX Technik AG
Brunnenweg 3
D 64331 Weiterstadt
Germany
www.lynx-technik.com
© 2015 LYNX Technik AG all rights reserved
R FR 5018 Reference Manual. Rev 1.0
Contents
Contents ............................................................................................................... 2
Warranty ............................................................................................................... 4
Regulatory information ........................................................................................ 5
Europe ....................................................................................................................................... 5
Declaration of Conformity ............................................................................................. 5
USA ............................................................................................................................................ 5
FCC 47 Part 15 ................................................................................................................... 5
SAFETY WARNING ............................................................................................... 6
WARNING! CAUTION! ......................................................................................... 6
SICHERHEITS WARNUNG!.................................................................................... 7
WARNUNG!ESD Warning ...................................................................................... 7
Getting Started ..................................................................................................... 9
Packaging .................................................................................................................................. 9
Product Description .................................................................................................................. 9
Power Supply ........................................................................................................................... 10
Rear Termination Panel .......................................................................................................... 11
Rack Connections ................................................................................................................... 11
Power Connection ................................................................................................................. 11
Alarm Connection ................................................................................................................. 12
Alarm Function ...................................................................................................................... 12
GPI Control ........................................................................................................................... 13
LAN Connection .................................................................................................................... 15
External Sync Connection..................................................................................................... 15
Alarm/LED Status Indicators .............................................................................. 15
Power Supply LED Indicators ......................................................................................... 16
Fan Alarm LED ..................................................................................................................... 16
Rack Configuration ............................................................................................ 17
Assembly ................................................................................................................................. 17
Rack Layout Considerations ................................................................................................. 17
Rear Connection Plates ........................................................................................................ 17
Redundant Power Supply ..................................................................................................... 17
Remote Controller ................................................................................................................. 17
Hot Swapping ..................................................................................................... 18
Power Supplies ........................................................................................................................ 18
Power Supply Failure ............................................................................................................ 18
CardModules ............................................................................................................................ 18
Air Flow .............................................................................................................. 19
Page 2 of 24
R FR 5018 Reference Manual. Rev 1.0
Rack Installation ................................................................................................ 20
Location ................................................................................................................................. 20
Ventilation ............................................................................................................................. 20
Mechanical Installation .................................................................................................... 20
Electrical Installation ........................................................................................ 20
Front Cover Removal .......................................................................................... 21
Compatibility with R FR 5010, R FR 5011and R FR 5012 .................................. 22
Installation Instructions .................................................................................... 23
Installations-Anweisung..................................................................................... 23
Specifications .................................................................................................... 24
Service ............................................................................................................... 25
Parts List ............................................................................................................................... 25
Technical Support .............................................................................................................. 25
Contact Information ........................................................................................... 25
Page 3 of 24
R FR 5018 Reference Manual. Rev 1.0
Warranty
LYNX Technik AG warrants that the product will be free from defects in materials and workmanship for a period of three (3) years from the date of shipment. If this product proves defective during the warranty period, LYNX Technik AG at its option will either repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product.
In order to obtain service under this warranty, customer must notify LYNX Technik of the defect before expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by LYNX Technik, with shipping charges prepaid. LYNX Technik shall pay for the return of the product to the customer if the shipment is within the country which the LYNX Technik service center is located. Customer shall be responsible for payment of all shipping charges, duties, taxes and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure, or damage caused by improper use or improper or inadequate maintenance and care. LYNX Technik shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than LYNX Technik representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non LYNX Technik supplies; or d) to service a product which has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty servicing the product.
THIS WARRANTY IS GIVEN BY LYNX TECHNIK WITH RESPECT TO THIS PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. LYNX TECHNIK AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. LYNX TECHNIK`S RESPONISIBILITY TO REPAIR AND REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. LYNX TECHNIK AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTIAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER LYNX TECHNIK OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
Page 4 of 24
We LYNX Technik AG Brunnenweg 3 D-64331 Weiterstadt Germany Declare under our sole responsibility that the product
TYPE: R FR 5018
To which this declaration relates is in conformity with the following standards (environments E1-E3): EN 55103-1 /1996
EN 55103-2 /1996 EN 60950-1 /2006 Following the provisions of 2004/108/EC and 2006/95/EC directives.
Winfried Deckelmann
Weiterstadt, May 2015 Place and date of issue Legal Signature
Regulatory information
Europe
Declaration of Conformity
R FR 5018 Reference Manual. Rev 1.0
USA
FCC 47 Part 15
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to the part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Page 5 of 24
R FR 5018 Reference Manual. Rev 1.0
SAFETY WARNING
Electrical supplies in excess of 50 (fifty) volts peak value are potentially hazardous or lethal. AC supplies between 100 and 250 peak volts exist within the rack frame chassis when connected to AC power. Only qualified personnel should service the rack frame assembly.
Removal of technical earth may render the equipment dangerous and intentional removal is prohibited.
This unit has to be separated from mains by disconnecting the power supply cords.
This unit may have two power supplies and two power supply cords. Disconnect all power supply cords before servicing to avoid electric shock.
The power cords must meet the safety requirements of the country where the rack frame is used and has to be approved in this country.
DOUBLE POLE / NEUTRALE FUSING After operation of the fuse, parts of equipment that remain energized might represent a hazard during servicing.
For continued protection against risk of fire, replace only with same type and rating of fuse. F1 .. F4: T2AH250V
Replacement AC fuses must be of the specified type and rating: F1 .. F4: T2AH250V The use of repaired fuses or shorting links has to be avoided.
Power Sockets for connection of the power cords to the unit have to be in close proximity to the rack frame and have to be accessible easily.
The unit has to be mounted in upright position (see instructions on page 20) Ensure that all connections with information technology equipment comply with
IEC 60950-1: 2005 / EN 60950-1: 2006.
WARNING! CAUTION!
Page 6 of 24
R FR 5018 Reference Manual. Rev 1.0
SICHERHEITS WARNUNG!
Wenn das Gerät an das Wechselstromnetz angeschlossen ist, treten innerhalb des Gerätes Wechselspannungen zwischen 100 und 250 V auf, die potentiell gefährlich oder tödlich sein können. Deshalb darf eine Reparatur und Instandhaltung nur von qualifiziertem Personal durchgeführt werden.
Das Entfernen des Schutzleiters kann das Gerät in einen gefährlichen Zustand bringen, vorsätzliches Entfernen des Schutzleiters ist verboten.
Das Gerät ist durch Abziehen beider Netzstecker vom Netz zu trennen. Das Gerät kann 2 Netzgeräte mit 2 Netzkabeln haben. Vor Servicearbeiten
müssen alle Netzkabel abgezogen werden, um elektrischen Schlag zu vermeiden.
Die Netzzuführung ist 2-polig abgesichert. Nach Ausfall einer Sicherung können Teile der Schaltung weiter unter Spannung bleiben und bei Servicearbeiten zu Gefahren führen. Vor Servicearbeiten Stromversorgung unterbrechen und Teile vor Berührung prüfen.
Nur Netzkabel benutzen, die für das Land, in dem der Träger benutzt wird, zugelassen sind.
Um Schutz gegen Feuer aufrechtzuerhalten, sind bei Sicherungswechsel nur Sicherungen des gleichen Typs mit gleichen Daten zulässig. F1 .. F4: T2AH250V
Steckdosen für den Anschluss der Netzkabel müssen sich in unmittelbarer Nähe des Gerätes befinden und müssen frei zugänglich sein.
Das Gerät darf nur bestimmungsgemäß, d.h. mit der Geräteoberseite nach oben installiert werden (siehe auch Hinweise auf Seite 20).
Es muss sichergestellt sein, dass alle Verbindungen mit anderen Geräten der Informationstechnologie der Norm IEC 60950-1: 2005 / EN 60950-1: 2006 entsprechen.
WARNUNG!
Page 7 of 24
R FR 5018 Reference Manual. Rev 1.0
ESD Warning
The internal electronics parts of this product are static sensitive. Please use caution and use preventative measures to prevent static discharge or damage could result to modules.
Electrostatic discharge (ESD) damage occurs when electronic assemblies or the components are improperly handled and can result in complete or intermittent failure.
Do not handle the module unless using an ESD-preventative wrist strap and ensure that it makes good skin contact. Connect the strap to any solid grounding source such as any exposed metal on the rack chassis or any other unpainted metal surface.
Caution
Periodically check the resistance value of the antistatic strap. The measurement should be between 1 and 10 Megohms.
Page 8 of 24