Lynx LX-218S User Manual

Page 1
Lynx Pro Audio S.L.
Valencia, Spain - www.lynxproaudio.com - info@lynxproaudio.com
USER MANUAL
V.10.13
LX-218S
V.13.10
Page 2
Manufacturer
CB SCHEME, IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT
CE CERTIFICACTION, EUROPEAN PRODUCT
LX-218S powered cabinet
LYNX Pro Audio S.L. Calle 7 - Pol. Ind. Picassent E-46220 Picassent (Valencia)
RoHS Directive 2002/95/EC
Page 3
CONTENTS
- SAFETY PRECAUTIONS
- CABINET INTRO
SPECIFICATIONS 5 BACK PANEL 6 CONNECTORS AND CONNECTIONS 6
- CONFIGURING THE CABINET DSP OPTIONS
CONFIGURATION PANEL 8 SELECT INPUT DIGITAL / ANALOG 8 SELECT AND RUN PRESETS 9 PRESET LIST 10 CARDIOID CONFIGURATION 11 ONLINE CONTROL SYSTEM 19 ETHERNET CONFIGURATION 20
- SOFTWARE, RAINBOW 26
- ACCESSORIES 28
- GUARANTEE 29
- DECLARATION OF CONFORMITY CE 30
Page 4
Before starting to use this device, please read this instruction manual carefully. Keep these instructions in the place where the equipment will be used and with easy access to them.
- Electrical appliance.
The exclamation mark within a triangle identifies the presence of electricity. Use the system carefully without wet hands or feet. Avoid installing the speaker in wet or excesivelly humid places. Regularly check the condition of the cables and make sure these are not being walked on or pinched. Connect the speaker to bipolar, earthed mains. The mains plug must be connected to the appropriate protection (fuse or breaker). Connection to any other type of mains could result in an electrical shock and violate local electrical codes. DO NOT CONNECT OR DISCONNECT THE AC POWER CONNECTORS UNDER LOAD.
- Heavy equipment.
Apply back protection when using the system. Avoid loading and unloading at heights.
- Electrical shock risk.
The diagonal mark within a triangle identifies the presence of dangerous voltage. Do not open or handle the interior of the box. These parts are not to be adjusted by the user. For maintenance and/or repair please go to an authorized service centre. In order to reduce the risk of electric shock, disconnect from AC before plug in or unplugging Audio signal cables. Reconnect to AC only if all signal connections are made and secured. Never manipulate the ground type plug provided. The AC mains plugs should always remain accessible for operation. Unplug the loudspeaker during storms or when it’s being used for a long time.
- Hearing damage risk.
These systems can reproduce large quantities of sound pressure which can damage hearing. Take precautions if you are going to be near them for extended amounts of time and do not get too close.
- Hanging – Flying.
Do not hang the cabinets from the handles or from any other part other than the designated hanging point. When flying this system please observe the technical and “Rainbow” software data carefully. Never exceed the maximum safe working loads or ignore the instructions included within this manual. Use Only flying accessories provided by Lynx Pro Audio S.L. Rigging must be always carried out by professionals.
- Delicate Material.
Please ensure no foreign object or water enters the speaker. Do not place material that contains liquid on or near the unit. Only clean the unit with dry cloths. Do not use solvents.
-Overheating – Fire risk.
To reduce the risk of the speaker over heating, avoid direct contact with sunlight. Avoid placing the unit close to heat inducing objects such as radiators. Do not cover the equipment in use and do not block any ventilation openings. Do not put naked flame, such as lighted candles, close or on top of the unit.
- Electromagnetic and interferente emissions.
Avoid placing objects which through electromagnetic waves can damage the unit, such as mobile phones, lap tops, magnetic strip cards etc.
This system complies with normatives EN 55103-1 (1)
EN 55103-2 (2)
(1) This device may not cause harmful interferences. (2) This device may receive interference including interferences that may cause undesired working.
-IMPORTANT NOTE.
This Equipment must be used in accordance with these instructions and by trained professional personnel only. This equipment should not be used in places with extreme tropical climates. Don’t expose this apparatus to extreme humidity and or temperature values.
Page 5
LX-218S
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
SPECIFICATIONS:
FREQUENCY RANGE 30Hz -200Hz FREQUENCY RESPONSE 35Hz- 125Hz ± 3dB
HORIZONTAL COVERAGE 360º single unit MAX SPL 136 dB/ 139dB peak
TRANSDUCERS LF: 2 x 18" Custom
Nomex Cone and Neodimium magnet SHAPE Direct radiation POWER AMPLIFIER 3000W Class D with Switching Power supply
2 x 1500W DSP Internal LYNX digital processor DSPB-22® CABINET ADJUSTMENT Back panel LCD screen INTERNAL CONTROLS Temperature sensor / Fan Speed SIGNAL CONNECTION NEUTRIK connectors XLR Male Input
XLR Female Loop Thru CONTROL CONECTIONS USB (DSP programming),
ETHERNET* (Online Monitoring System OMS®) AC POWER 230v / 115v selectable. 50/60 Hz 3A AC CONECTIONS 16A NEUTRIK POWERCON with Looping Output CONSTRUCTION 21 mm Premium birch plywood FINISH High resistant water-based black paint FRONT DESIGN Black steel grille
DIMENSIONS (H x W x D) 532 x 1080 x 700 mm WEIGHT 72 Kg (158 lbs)
INTRODUCTION
To facilitate, correct and reliable use of the Lynx LX-218S we have designed this instruction manual. Please read the manual carefully before proceeding to install the system.
When flying this system please observe the technical and “Rainbow” software data carefully. Never exceed the maximum safe working loads or ignore the instructions included within this manual.
5
* Ethernet is optional
Page 6
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
LX-218S
LX-218S BACK PANEL.-
12 5
6 43
1.- SIGNAL INPUT.
2.- SIGNAL LINK.
3.- INPUT AC.
4.- AC LINK (máx. +1 cabinets).
5.- USB.
6.- DSP CONTROL.
CONNECTORS AND CONNECTIONS
XLR AEREAL CONNECTORS
Connect to output
Connect to input
2 Live(+)
3 Live(-)
1 Earth
3 Live(-)
1 Earth 2 Live(+)
OUTPUTS
1.- EARTH
2.- LIVE (+)
3.- LIVE (-)
1
3
2
INPUTS
1.- EARTH
2.- LIVE (+)
3.- LIVE (-)
2
3
1
XLR SOCKET CONNECTORS
6
Page 7
LX-218S
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
Connect to AC output (max.2 cabinets)
Connect to signal output
CONNECTION EXAMPLE: 4 LX-218S CABINETS
Connect to AC output (max.2 cabinets)
SOCKET POWERCON CONNECTORS
CAUTION: Do not connect or disconnect the AC Power connectors under load.
L - Line N - Neutral
- Earth
7
Page 8
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
LX-218S
CONFIGURING THE CABINETS DSP OPTIONS
From the buttons below the display on the Lynx cabinet’s back panel you are able to configure the Basic
adjustment functions of the internal DSP. Note:
You must apply the desired configuration in each cabinet. This is done via the buttons located on the back panel of the cabinet and requires electrical power to work.
CONFIGURATION PANEL
On the back panel you will see 3 buttons and an information screen, on which you can read the established parameters and information such as input mode (analog or digital), amplification module temperature, input signal level and name of the current preset (Fig1). If changes are not made the display will automatically dim to save energy and avoid unnecessary light in situations where light is not wanted. To re-activate the light simply press the OK button.
8
SELECT THE INPUT: DIGITAL OR ANALOG
There are four input options: Analog / Digital L / Digital R / Digital L+R To select the input mode just press the OK button (3) and keep pressing down whilst at the same time you press
the up button (1). One of the four options will appear on the screen. Then you can use the up button (1) to search the option required. To confirm your selection press OK (3) until the progress bar finishes. The display will show an inverted D (digital) or an inverted A (Analog) so you can always know if the input is digital or analog.
1
2
3
Fig 1
Page 9
LX-218S
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
Fig 3 Fig 4
Note: In case of a power cut, the DSP will save its last configuration when restarted.
9
SELECT AND RUN PRESETS
To change the preset configuration just press the up button (1) and down button (2) until you see the title and preset number required (Fig2). Once found, press OK (3) until the progress bar finishes (Fig3). The display will indicate “Loading DSP” (Fig4)
Fig 2
Page 10
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
LX-218S
PRESET LIST
From the buttons below the display on the cabinet’s back panel you are able to configure the Basic adjustment functions of the internal DSP. Depending on the model, you can find the following configurations:
Note: You must apply the desired configuration in each one cabinet. This is done via the buttons located on the back panel of the cabinet and requires electrical power to work.
10
Page 11
LX-218S
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
11
CARDIOID CONFIGURATIONS
Mode 1:
- For A cabinets use preset 10
- For B cabinets use preset 11
- With this configuration we obtain around 24 dB of attenuation between 30Hz and 100Hz, and between 1 and 1.5 dB more SPL up front.
A
A
B
20 30
40
50 60
70
80
90 100
(Hz)
0
-3
-6
-9
-12
-15
-18
-21
+3
+6
+9
(dBr)
Mode 1: Front
Mode 1: Rear Normal Mode: Front Normal Mode: Rear
Image 1: Polar response for Mode 1 at 60 Hz Image 2: Polar response at 60 Hz (2 cabinets)
Graphic 1: Mode 1 vs. Normal Mode
Page 12
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
LX-218S
12
CARDIOID CONFIGURATIONS
Mode 2:
- For A cabinets use preset 10
- For B cabinets use preset 12
- With this configuration we obtain around 24 dB of attenuation between 30Hz and 100Hz, and between 1 and 1.5 dB more SPL up front.
A
B
A
20 30
40
50 60
70 80 90 100
(Hz)
0
-3
-6
-9
-12
-15
-18
-21
+3
+6
+9
(dBr)
Mode 2: Front Mode 2: Rear Normal Mode: Front Normal Mode: Rear
Image 3: Polar response for Mode 2 at 60 Hz
Image 4: Polar response at 60 Hz (2 cabinets)
Graphic 2: Mode 2 vs. Normal Mode
Page 13
LX-218S
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
13
CARDIOID CONFIGURATIONS
Mode 3:
- For A cabinets use preset 10
- For B cabinets use preset 13
- With this configuration we obtain around 23 dB of attenuation between 30Hz and 100Hz, and between 1 and 1.5 dB more SPL up front.
B
A
A
20 30
40
50 60
70
80
90 100
(Hz)
0
-3
-6
-9
-12
-15
-18
-21
+3
+6
+9
(dBr)
Mode 3: Front
Mode 3: Rear Normal Mode: Front Normal Mode: Rear
Image 5: Polar response for Mode 3 at 60 Hz
Image 6: Polar response at 60 Hz (2 cabinets)
Graphic 3: Mode 3 vs. Normal Mode
Page 14
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
LX-218S
14
CARDIOID CONFIGURATIONS
Mode 4:
- For A cabinets use preset 10
- For B cabinets use preset 14
- With this configuration we obtain around 23 dB of attenuation between 30Hz and 100Hz, and between 1 and 1.5 dB more SPL up front.
A
B
20 30
40
50 60
70
80
90 100
(Hz)
0
-3
-6
-9
-12
-15
-18
-21
+3
+6
+9
(dBr)
Mode 4: Front
Mode 4: Rear Normal Mode: Front Normal Mode: Rear
Image 7: Polar response for Mode 4 at 60 Hz
Image 8: Polar response at 60 Hz (2 cabinets)
Graphic 4: Mode 4 vs. Normal Mode
Page 15
LX-218S
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
15
CARDIOID CONFIGURATIONS
Mode 5:
- For A cabinets use preset 10
- For B cabinets use preset 15
- With this configuration we obtain around 23 dB of attenuation between 30Hz and 100Hz, and between 1 and 1.5 dB more SPL up front.
B
A
20 30
40
50 60
70
80
90 100
(Hz)
0
-3
-6
-9
-12
-15
-18
-21
+3
+6
+9
(dBr)
Mode 5: Front
Mode 5: Rear Normal Mode: Front Normal Mode: Rear
Image 9: Polar response for Mode 5 at 60 Hz
Image 10: Polar response at 60 Hz (1 cabinet)
Graphic 5: Mode 5 vs. Normal Mode
Page 16
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
LX-218S
16
CARDIOID CONFIGURATIONS
Mode 6:
- For A cabinets use preset 10
- For B cabinets use preset 16
- With this configuration we obtain around 24 dB of attenuation between 30Hz and 100Hz, and between 1 and 1.5 dB more SPL up front.
A B A
20 30
40
50 60
70
80
90 100
(Hz)
0
-3
-6
-9
-12
-15
-18
-21
+3
+6
+9
(dBr)
Mode 6: Front Mode 6: Rear Normal Mode: Front Normal Mode: Rear
Image 11 Polar response for Mode 6 at 60 Hz
Image 12: Polar response at 60 Hz (2 cabinets)
Graphic 6: Mode 6 vs. Normal Mode
Page 17
LX-218S
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
17
CARDIOID CONFIGURATIONS
Mode 7:
- For A cabinets use preset 10
- For B cabinets use preset 17
- With this configuration we obtain between 15 and 28 dB of attenuation from 30Hz to 100Hz, and between 1 and 2 dB more SPL up front.
B A
20 30
40
50 60 70 80 90 100
(Hz)
0
-3
-6
-9
-12
-15
-18
-21
+3
+6
+9
(dBr)
Mode 7: Front
Mode 7: Rear Normal Mode: Front Normal Mode: Rear
Image 13: Polar response for Mode 7 at 60 Hz
Image 14: Polar response at 60 Hz (1 cabinets)
Graphic 7: Mode 7 vs. Normal Mode
Page 18
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
LX-218S
18
NOTES:
- All measurements have been taken in the open air.
- Measurements carried out in “Half Space”.
- In a closed room the response can vary depending on distance between walls, ceiling etc.
- The graphs are shown in relative dB measurements.
- The polar responses are shown in dB SPL obtained from acoustic prediction.
Page 19
LX-218S
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
19
ONLINE CONTROL SYSTEM
Who is it for?
Users of Self powered DSP incorporated Lynx Pro Audio Cabinets where the user has requested the cabinets be supplied with the Ethernet Module kit.
What is it for?
Obtain detailed information of cabinet behaviour and monitor the cabinet/s in real time. You can change the preset, gain, mute, polarity and phase. You can also activate the air absorption compensation and select the «SOLO» mode.
How does it work?
Via Ethernet (cable or wireless). Once installed, the O.C.S. software automatically detects all the cabinets connected to the network and displays them in the O.C.S. window on the users PC.
What does it show?
As well as displaying the cabinet model and IP address the O.C.S will be monitoring in real time and the user will be able to view RMS levels, Input clip, power module temperature, compression levels, air absorption compensation and cabinet angulation.
Page 20
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
LX-218S
CONFIGURING ETHERNET TO WORK WITH LX-218S
There are two possible ways to connect:
1.- Connecting through an ETHERNET SWITCH/HUB::
- You will need a normal CAT5 Cable.
2.- Connecting through a Wirless ETHERNET.
Let us now proceed to configure the Ethernet network, setting the IP address of the computer as static. To do this go to:
START > CONFIGURATION > NETWORK CONFIGURATION
We will launch the properties of "Local Area Connection" by clicking the right mouse but­ton and clicking on properties.
20
Page 21
LX-218S
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
Select "Internet Protocol (TCP / IP)" and click on properties.
Select: “Use next IP Address” And write as you wish, in order to configure your network.
Normally, Ip values will be something like this:
IP Address: 192.168.1.xxx Subnet Mask: 255.255.255.0
Where xxx will be a number between 1 and 254 Accept to quit the network settings and again to
apply them at the next screen. Depending on the Windows Version, you will be asked to reboot or not.
Once the Computer is configured with a static IP proceed to connect to the line array system through the O.M.S. (online monitoring system) software.
Open the OCS software and from the Initial Screen choose Ethernet device into the configuration menu.
It will open a different screen, as follows, there you can see your Network configuration, and the cabinets currently connected.
21
Page 22
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
LX-218S
If you want to change the IP select the cabinet and modify the assigned IP in order to be able to connect to it.
By default, the Cabinet will have this IP 192.168.2.100
The Network enviroment consists in the first 3 sets of three numbers separated by dots. In order to detect/communicate with the cabinets, the software and the cabinets must have the same Network settings.
If it is not in the same environment Windows Profesional (2000, XP, VISTA, Windows 7 and 8) will detect it, but is not going to be able to establish connection. In Windows Home, the processor is not going to be detected until the same enviroment is applied.
In order to change the IP settings to have the same configuration as the PC, we can change the IP address of the cabinets by clicking in the Assign IP to select Device button after writing in the box above the desired data. Remember there cannot be two devices with exactly the same IP address, the last set of three numbers has to be different and unique to each one of the devices.
22
Page 23
LX-218S
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
for example, write 192.168.1.100 and click "Change Device IP" button. The OCS software will send the new IP to the cabinet and it will scan the network again showing the same information
as before, plus more information such as Pc name, IP address and Port in which the communication is established.
When we have a lot of cabinets connected in the network we can use the button “Identify Device” to see which box is selected (two activity LEDS will blink for one second). With that information then we can Change device NAME assigned to this Cabinet by clicking in the Change device name” button after writing in the box above the desired Name.
Returning to the main screen, we can see each cabinet showing: Model, IP address and Name, as well as monitoring: RMS levels, Input clip, power module temperature, compression levels, air absorption compensation and cabinet angulation, as well as displaying the cabinet model and IP address.
23
Page 24
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
LX-218S
If you need to know the PC Network settings go to:
START > ALL PROGRAMS > ACCESSORIES > Command Prompt
It will open the cmd.exe from where you can type the IPCONFIG command ( ipconfig + Enter), which will show your actual IP settings.
Here we can see that this PC has IP set as 192.168.2.99.
24
Page 25
LX-218S
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
You can also use the command promt to know if an IP is already in use by another device. In this case type "ping IP" (ping 192.168.2.xxx) and press enter. If there is no device with this IP you will see the following information:
If the IP is in use, the device will respond to the Ping, and we will obtain this information:
You now have the Cabinets working in the ETHERNET Network Enviroment.
25
Page 26
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
LX-218S
RAINBOW – ACOUSTICAL PREDICTION SOFTWARE
Thanks to the RAINBOW software, you will be able to “virtually” determine the acoustical response of one or various cabinets at the same time.
Based on polar response measurements, taken meticulously with a 360º coverage both vertically and horizontally, the Rainbow software is able to calculate the SPL response including the interaction between them taking into account the magnitude and phase response, in order to enable the user to correct cancellations and even to create them if the acoustical design so requires.
Rainbow is very easy to use and offers a very intuitive design, multitool interface and on-line updatable data base.
The Rainbow software has been designed by and for sound technicians. Its aim is to help installers and users of Lynx pro audio products.
This software is able to import WMF Vector Files with technical drawings and insert them directly into the prediction window and thus enabling real measurement predictions.
This also helps to determine dead zones and obtain the maximum performance from each of the cabinets installed.
26
Page 27
LX-218S
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
Features
The RAINBOW acoustical prediction software allows among other things:
- Prediction up to 4 LINE ARRAYS of 24 cabinets each simultaneously, together with multiple points with cabinets
- Flying points information according to the inclination of the cabinets
- Weight calculation of the different systems
- Sub-bass simulation (for instance to achieve cardiod configurations)
- Orientation of cabinets (Horizontal/vertical)
- Throw Direction of cabinets (right/ left)
- Individual delay per cabinet/system
- Polarity selection for each cabinet
- Up to 40 process insertions with Equalization and CrossOver assignable per cabinet.
- Simulation of the Air absorption sound loss with the distance
- SPL Pressure information
- Distance measurement
- Import of CAD files
- Up to 4 audience or hearing zones
- Coverage curves on the hearing zones.
- Export of SPL Map and coverage curves on jpg or bmp format
- Print project report (SPL prediction, flying points, weights, cabinet inclination, polarities, process aplied, EQ Curves…)
27
Page 28
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
LX-218S
ACCESSORIES
The LX-218S sub unit has at its disposal some practical accessories to help use the system in a number of applications.
FD-2LX218S FD-3LX218S
Nylon protection cover for either 2 or 3 cabinets
FD-1LX218NL
Rain cover for the back pannel
CA-LXV8
Transport dolly for up to 3 LX-218S
STK-218
Adaptor to stack ADP-215 over vertical LX-218S
28
Page 29
LX-218S
LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
LYNX PRO AUDIO GUARANTEE
Lynx products are guaranteed against every kind of manufacturing fault 2 year after the date of sale. When products are under guarantee, the repairing and the free supplying of the device parts in order to correct any kind of defect are guaranteed by Lynx Pro Audio S.L. In the case that the product could not be returned to the factory for checking and repairing, Lynx Pro Audio S.L. would supply all the necessary parts.
Lynx Pro Audio S.L. is not responsible for any damage or defect caused during the transport or caused by an undue or improper handling y a non-authorized person during the life of this guarantee.
All our products undergo rigorous tests and quality controls. We guarantee the characteristics described here within and their quality against any fabrication defect.
The user loses all warranty rights if he incorporates or carries out any modification to the product, if he uses it outside of the stated safe working loads or does not secure the system properly using all the pins in their corresponding holes.
For any question regarding the product, the user must quote the model and serial number.
29
Page 30
DECLARATION OF CONFORMITY
LYNX Pro Audio S.L.
Calle 7 - Pol. Ind. Picassent
E-46220 Picassent (Valencia)
Lynx Pro Audio S.L. declares that LX-218S cabinets are in conformity with the following EC directives: Low Voltage Directive 2006/95/EC
Electromagnetic Compatibility EMC 2004/108/EC RoHS Directive 2002/95/EC
In accordance with Harmonized European Norms: EN 60065:2002 Audio, video and similar electronic apparatus. Safety requirements EN 55103-1:1996 Electromagnetic compatibility. Product family standard for audio, video, audiovisual
and entertainment lighting control apparatus for professional use. Part 1: Emission.
EN 55103-2:1996 Electromagnetic compatibility. Product family standard for audio, video, audiovisual
and entertainment lighting control apparatus for professional use. Part 2: Immunity.
WEEE Declaration: Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime. Please dispose of this product according to the respective national regulations or contractual agreements. If there are any further questions concerning the disposal of this product please contact Lynx Pro Audio S.L.