EXTERIOR DIMENSIONS
INSTALLATION PREPARATION
INSTALLER: Read these instructions carefully before starting installation. Please leave these instructions with the homeowner.
HOMEOWNER: Please retain these instructions for future use
Cutout Dimensions Exterior Dimensions
Cut-out Dimension
Width A Height B Depth C Width D Depth E Depth F
Specifications
LCS30 29 10½ 22 31 251/
Counter top notch detail: a 1/2” width is required with a depth equal to the counter top overhang.
8
F
E
221/
D
8
Exterior DimensionsCutout Dimensions
The Lynx sinks are designed for outdoor use. It is recommended that the sink be installed by a qualied technician
in accordance with all local plumbing and building codes.
Prepare the counter top by cung the appropriate cutout dimensions from the table above. There must be a minimum of a 1/2” overlap on the sides and rear of the sink on the counter top to support the sink. Adequate
clearances below the sink must be maintained for maintenance, water, and drain lines.
LCS30 COCKTAIL STATION CARE & USE/INSTALLATION
3
|
INSTALLING THE DRAIN ASSEMBLY
INSTALLING THE DRAIN ASSEMBLY
2. Remove the drain plug strainer basket (a) and separate the upper drain ng (b) from the remainder of the drain assembly.
3. Place a bead of Plumbers Puy* around the underside lip of the upper drain ng. Drop the upper drain ng
(b) into the sink boom opening and press it rmly into place. From the boom of the sink posion the rubber gasket (c) and then the paper gasket (d) on the upper drain ng (b). The paper gasket (d) is used to prevent kinking of the rubber gasket (c) while ghtening the locknut (e).
4. Align the drain assembly so that it sits centered in the sink drain cut-out. Screw the locknut (e) on to the upper drain ng (b) threaded connecon unl it is hand ght. Now use a tool to ghten the locknut (e) another
quarter turn.
5. Remove any excess Plumber Puy with a damp cloth.
* Plumbers Puy is available at most home improvement centers. Plumbers puy is an easy-to-mold seng compound for use with stainless steel sealing applicaons. Do Not Omit This Step.
For ease of installaon we recommend that the drain assembly be installed before installing the sink into the counter
top.
1. Remove the drain assembly from the box and idenfy the following parts:
a. Drain Plug/Strainer Basket
Sink Boom
Sink Opening
b. Upper Drain Fing
c. Rubber Gasket
d. Paper Gasket
e. Locknut
f. Tailpiece
g. Threaded Coupling
LCS30 COCKTAIL STATION CARE & USE/INSTALLATION4
|
1. Install the faucet or the stainless steel plug (included) into the top faucet opening.
INSTALLING THE SINK
INSTALLING THE DRAIN PIPING (NOT SUPPLIED)
INSTALLING THE TRANSFORMER
2. Carefully lower the sink into the cut out on the counter top. Push the sink back unl there are no gaps in the back and the bullnose contacts the front face of the cabinet. The sink will be supported by its weight on the side and back.
3. If desired a small bead of silicone sealant could be put around the edges of the sink to prevent water seepage into the spaces below the sink.
Faucet installation instructions available in the faucet box.
Assemble all drain pipe connecons to the tailpiece and on through a pipe trap and proper drainage. The drain
must be installed in accordance with all local codes. In the absence of local codes, the requirements of the Uniform Plumbing Code should be followed.
The power supply transformer should be installed below the sink within the cabinet enclosure. Select a locaon
where the transformer is protected against water, heat and physical damage. It is recommended that fasteners are
used in at least two of the four mounng holes for secure aachment.
The power supply transformer must be plugged into a properly grounded GFI equipped outlet, installed by a
qualied technician. The outlet of the transformer is plugged into the white Molex connector at the rear of the sink. Please see the electrical diagram provided in this manual.
LCS30 COCKTAIL STATION CARE & USE/INSTALLATION
5
|
INSTALLING THE LCS30 FRONT COMPONENTS
1. Located the supplied hardware bag with 3 stainless shoulder screws and 2 stainless philips head screws.
2. Install the two stainless steel shoulder screws into the right hand side inserts of the front panel.
3. Carefully lower the bole holder on the newly aached shoulder screws.
4. When installing the bole opener you will need to Install the third shoulder screw directly below the far le
insert. Aach the top of the bole holder when you install the towel bar, as they share the screw.
5. Connue to install the towel bar using the second stainless steel phillips head screw provided.
Stainless Steel Screws
Stainless Steel Shoulder Screws
LCS30 COCKTAIL STATION CARE & USE/INSTALLATION6
|
INSTALLING THE LCS30 COMPONENTS
1. Set the bole cup holder into the sink opening. The sink has a recessed opening in which the support rests.
2. Lower the bole wells into each opening of the well support.
3. Insert the ice sink into the sink opening, resng on the recessed opening.
4. In this order, drop in the slide support, the strainer basket and the slide cover into the sink opening. You will
need to hook the back fold of the slide cover onto the ared back end of the slide support.
Ice Sink
Slide Cover
Flared back end of slide support
Strainer Basket
LCS30 COCKTAIL STATION CARE & USE/INSTALLATION
7
|
ASSEMBLING THE LCS30 PASS SHELF (OPTIONAL)
1. Aach the support legs to the pass shelf top with the four shorter provided stainless steel screws.
2. Feed the light harness through the far le rear opening.
3. Carefully match up all four support legs with their corresponding openings in the pass shelf base.
4. Using the four longer provided stainless steel screws, secure the base to the pass shelf support legs. There are
metal inserts with threaded openings within the support legs to ax the screw to.
5. Hook the condiment tray onto the top le rail of the pass shelf top.
LCS30 COCKTAIL STATION CARE & USE/INSTALLATION8
|
INSTALLING THE LCS30 PASS SHELF (OPTIONAL)
FREESTANDING ASSEMBLY
1. Remove the rear panel of the cart, and the two brackets (shown in detail F) holding in the rear ller plate.
2. With the panel removed, pull o the stainless steel rear ller.
3. Unscrew the large nut holding the faucet in place, and remove the faucet.
4. Set the pass shelf on top of the sink, carefully matching the opening of the sink with the opening of the pass shelf base.
5. Once all hoses have been fed through the holes assemble the faucet per the original instrucons (included).
6. Connect the molex connector from the light harness to the wiring harness from the sink.
7. Re-aach the rear panel.
Transformer Connection
Sink Wire Harness
LCS30 Pass Shelf Light Connection
F
LCS30 COCKTAIL STATION CARE & USE/INSTALLATION
DETAIL F
SCALE 1 : 5
9
|
INSTALLING THE LCS30 PASS SHELF (OPTIONAL)
BUILT IN ASSEMBLY
1. Access the faucet underneath the sink, and unscrew the large nut holding the faucet in place, and remove the faucet.
2. You will need to drill a 1” round hole in the back le corner to accommodate for the wiring harness to drop
down to aach to the wiring harness of the sink
3. Set the pass shelf on top of the sink, carefully matching the opening of the sink with the opening of the pass shelf base.
4. Once all hoses have been feed through the holes assemble the faucet per the original instrucons.
5. Connect the molex connector from the light harness to the wiring harness from the sink.
LCS30 COCKTAIL STATION CARE & USE/INSTALLATION10
|
CONTACTING LYNX CUSTOMER CARE
• TGI Fridays
• Applebee’s
• Houston’s
• Red Lobster
• Hard Rock Café
• Wolfgang Puck’s
• Cheesecake Factory
• Red Robin
• Planet Hollywood
• Hilton
• Hyatt
• Four Seasons Marriott Le Meridian
• Sheraton
• Conrad International
• Bellagio
• New York New York
• MGM Grand
• Treasure Island
• Mirage
• Paris
• Venetian
• Excalibur
• Mandalay Bay
• Riviera
• Desert Inn
• Hard Rock Hotel
• Disney World
Before calling Lynx Customer Care, please make sure you have the following information:
• Model number
• Date of purchase
• Proof of purchase by the original owner
• Serial number
The serial number can be located on the rating plate which is located on interior of the front panel.
(888) 289-5969
www.lynxgrills.com
Your satisfaction is of the utmost importance to us. If a problem cannot be resolved to your satisfaction, please write, fax or email us:
Lynx Professional Grills
7300 Flores Street
Downey, CA 90242
Service: (888) 289-5969
Tel: (562) 299-6900
Fax: (562) 299-6978
www.lynxgrills.com
Contact Lynx for replacement parts. Parts are shipped F.O.B. Downey, CA.
For warranty service, contact the Lynx Customer Care Department for an authorized service agent near you at:
THE LYNX STORY
Lynx began with a vision.
A small group of manufacturing engineers with over a century of collective experience had a dream. They dared to take their extensive commercial manufacturing know-how and create a line of outdoor cooking products that offer commercial elegance and performance to the consumer market.
Lynx has taken the quality, workmanship, service and innovation of the commercial market and incorporated it into the Lynx Professional Grills line of consumer and commercial products. The combination of creative design, superior materials and exceptional craftsmanship elevates Lynx products to a class of their own.
Lynx original commercial products are used every day in restaurants, hotels and theme parks across the USA:
LYNX SATISFIED CUSTOMERS
LCS30 COCKTAIL STATION CARE & USE/INSTALLATION
11
|
STAINLESS STEEL
LCS30 CARE
Lynx products are known for their attractive appearance. We achieve this by selecting only the finest grades of stainless steel and applying exacting workmanship.
In order to maintain this attractive appearance over the life of the grill it is important to take the following steps:
• Use a commercially available Stainless Steel cleaner* to
clean and polish the exterior surfaces.
Doing these things on a regular basis minimizes the amount of effort required.
Part of the appeal of your Lynx Accesory is the fine grain finish. When removing stubborn stains:
• Do not use metallic abrasives and always rub in the
direction of the grain.
• Some household cleaning products are not suitable for
stainless steel; be sure to read the label before using on your Lynx Accesory.
• Always use the mildest cleaning solution first, scrubbing
• Regularly wipe down the exterior surfaces with a damp cloth. (Micro fiber cloths such as Ecloth perform very well).
• Allow the surfaces to dry before installing the cover. Do not cover a damp sink.
• In extreme environments apply a rust inhibitor which leaves a microscopic protective layer on the stainless. Products that provide a layer of vapor corrosion inhibitors (VpCI™) protect the surface very well.
• For seasonal storage use the product referred to above, ensure the sink is dry and then cover and secure the cover to minimize the amount of damp air getting to the surfaces.
THE LYNX LIMITED LIFE TIME WARRANTY PROVIDES PROTECTION AGAINST RUST THROUGH OF PARTS THAT RENDER THE PRODUCT INOPERATIVE. IT DOES NOT COVER OCCASIONAL SURFACE RUST OR STAINING DUE TO ENVIRONMENTAL CONDITIONS.
For light and heavy food stains there are many different stainless steel cleaners available.
in the direction of the grain. Specks of grease may gather in the grain of the stainless steel and bake on to the surface, giving the appearance of rust.
To remove these baked-on foods use a fine to medium grit non-metallic abrasive pad (Scotch Brite is good) in conjunction with a stainless steel cleaner.
• Solutions used for cleaning concrete and masonry can be very corrosive and will ‘attack’ stainless steel. Ensure your Lynx products are well protected before you allow the use of such chemicals.
SPECIAL NOTE FOR LOCATIONS NEAR POOLS AND COASTAL AREAS:
The 304 stainless steel material used in the construction of a Lynx Grill is highly rust resistant, however, chlorine in the air from swimming pools or the salt from sea air may cause surface rust to appear and even create some pitting if left on the product.
Here are a few tips to avoid this:
*For optional pass shelf*
Replacement bulbs are halogen, 12 volt, 10W max, T3 type with a G4 bi-pin, and are readily available at most stores. The glass cover is held in place by two spring tension tabs. The bulbs are easily removable without the use of tools. Simply grasp the glass lens at the outer corners, near the front tension clips and push the lens back. Then, swing the lens down and pull it loose. You may have to loosen the screw to remove the lens.
Avoid touching the glass of a new bulb. Halogen bulbs are very sensitive to the oils found in human skin. Touching the bulbs may shorten their life.
Pull the bulb straight out from the socket without twisting.
Hold the bulb using a paper towel or other cloth and gently press it straight into the socket. The glass cover should be gently snapped back into place.
LCS30 COCKTAIL STATION CARE & USE/INSTALLATION12
|
EXPLODED VIEW/PARTS
10
3
4
2
1
17
14
7
9
12
8
13
6
11
5
8
COVER IS PART OF ITEM #1 AND ISTALLS ON TOP OF THE ASSEMBLY
15
16
18
17
ITEM
PART NO.
1 81103 2 36080 3 11004 4 36081 5 35754 6 35751 7
L10003 83 2222 9 70547
10 11 32767 12 36084 13 36082 14 36085 15 36086 16 31379 17 36101 18 36072
LPFK
DESCRIPTION
SINK ASSEMBLY, 30 CUP HOLDER BOTTLE WELL ICE SINK BOTTLE AND SPICE, LARGE TOWEL BAR, SHORT BOTTLE OPENER SCREW, SHLDR, #10-32 X 1/4, SLTD, SS, 1/4 DIA X 1/8 CAP CUP FAUCET, GOOSE NECK PULL-DOWN SCREW, #10-32 X 3/8, THP, SS SLIDE FRAME BASKET, STRAINER SLIDE BACK SLIDE FRONT HANDLE, 4" STAINLESS DART, NYLON SCREW, #10-24 X 1/2, THP, SS
LCS30 COCKTAIL STATION CARE & USE/INSTALLATION
Defa ult/Q
TY.
1 1 3 1 1 1 1 3 1 1 2 1 1 1 1 1 3 2
13
|
EXPLODED VIEW/PARTS
Optional Pass Shelf
4
5
4X
2
9
4X
6
3X
8
3
2X
1
7
3X
ITEM
1 70552
2 70553
3 70550
4 36094
5 11114
6 35139
7 14043
8 80353
9 14014
PARTNO.
DESCRIPTION QTY.
PASS SHELF BASE
PASS SHELF TOP WELDMENT
SUPPORT LEG P. SHELF WELDMENT
TRAY, CONDIMENT
TRAY, CONDIMENT CS30
RETAINER, 1/4-20 THREADED
SCREW, 1/4-20 X 1, FHP, SS
LIGHT ASSY CSPS 2008
SCREW, #8-32 X 3/8, THP, SS
1
1
2
1
4
3
3
1
4
LCS30 COCKTAIL STATION CARE & USE/INSTALLATION14
|
SCHEMATICS
LCS30
Light Switch
LCS30 COCKTAIL STATION CARE & USE/INSTALLATION
15
|
LCS30 COCKTAIL STATION CARE & USE/INSTALLATION16
PRODUCT DIMENSIONS/CUT OUT DIMENSIONS (IN BLUE)
|
LYNX LIMITED WARRANTY
I. Limited Lifeme Warranty
The stainless steel housing is warranted to be free from defects in material and workmanship when subjected to normal domesc use and service for the lifeme of the original purchaser. This warranty excludes surface corrosion, scratches, and discoloraon which may occur during regular use. This warranty is limited to the replacement of the defecve parts, with the owner paying all other cost
including labor.
II. Limited ONE-Year Warranty
All other components are warranted to be free from defects in material and workmanship for a period of one year from the original date of purchase. Lynx will replace or repair parts found to be defecve at no cost to the original purchaser.
III. Limitaons & Exclusions
1. This Warranty shall apply to products purchased and located in the United States and Canada. Products must be purchased in the
country where service is requested.
2. Warranty applies only to the original purchaser and may not be transferred.
3. Warranty is in lieu of all other warranes expressed or implied and all other obligaons or liabilies related to the sale or use of its products.
4. Warranty shall not apply and Lynx is not responsible for damage resulng from misuse, abuse, alteraon of or tampering with the
appliance, accident, hosle environment, improper installaon, or installaon not in accordance with the instrucons contained
in this manual, or the local codes.
5. Lynx shall not be liable for incidental, consequenal, special or conngent damages resulng from its breach of this wrien warranty or any implied warranty.
6. Some states do not allow limitaons on how long an implied warranty lasts, or the exclusions of or limitaons on consequenal
damages. This warranty gives you specic legal rights and you may have other rights which vary from state to state.
7. No one has the authority to add to or vary Lynx’s warranty, or to create for Lynx any other obligaon or liability in connecon with the sale or use of its products.
8. Limited to the replacement of defecve parts with the owner paying all other costs including labor.
IV. What is not covered: Lynx shall not be responsible for and shall not pay for the following
1. Damages or problems caused by improper installaon or use;
2. Service by an unauthorized service provider;
3. Damage or repair due to service by an unauthorized service provider or use of unauthorized parts;
4. Warranty does not apply to products installed in any commercial or non-residenal applicaon. Examples of excluded applicaons
include, but are not limited to day care centers, schools, bed and breakfast centers, churches, private clubs, re staons, club houses, common areas in mul-family dwellings, restaurants, hotels, nursing homes, food service locaons and instuonal food service locaons.
5. To correct normal adjustments or sengs, due to improper installaon, commissioning or local supply properes;
6. Shipping and handling costs, export dues, installaon, removal, or re-installaon cost.
7. Display models are generally sold “as is.” If you have purchased a display model, please be advised that it is sold “as is” and that
it is subject to the following warranty exclusions: any exterior or cosmec damage is non warrantable; any missing components will be re-placed at consumers expense; major handling damage will be serviced at consumer’s expense; all other warranty’s (standard warranty) will remain in eect.
8. The cost of a service call to diagnose trouble.
LCS30 COCKTAIL STATION CARE & USE/INSTALLATION
17
|
P/N 36110 Rev.A 2/2017
The best outdoor kitchen products come from:
Lynx Grills, Inc. 7300 Flores Street Downey, CA 90242
Service: (888)-289-5969 Fax: (562) 299-6789