Lynx C DA 5005 Reference Manual

Series 5000
Brunnenweg 3
D-64331 Weiterstadt
Germany
www.lynx-technik.com
Reference Manual
C DA 5005
5 Channel SDI to CVBS Converter
CardModule
Version 1.0
Reference Manual C DA 5005 Version1.0
Page 2
Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical for any purpose, without express written permission of LYNX Technik AG.
LYNX Technik AG may have patents, patent applications, trademarks, copyrights or other intellectual property rights covering the subject matter in this document. Except as expressly written by LYNX Technik AG, the furnishing of this document does not give you any license to patents, trademarks, copyrights or other intellectual property of LYNX Technik AG or any of its affiliates.
© LYNX Technik AG 2003 all rights reserved
Reference Manual C DA 5005 Version1.0
Page 3
Warranty
LYNX Technik AG warrants that the product will be free from defects in materials and workmanship for a period of two (2) year from the date of shipment. If this product proves defective during the warranty period, LYNX Technik AG at its option will either repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product.
In order to obtain service under this warranty, customer must notify LYNX Technik of the defect before expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by LYNX Technik, with shipping charges prepaid. LYNX Technik shall pay for the return of the product to the customer if the shipment is within the country which the LYNX Technik service center is located. Customer shall be responsible for payment of all shipping charges, duties, taxes and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure, or damage caused by improper use or improper or inadequate maintenance and care. LYNX Technik shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than LYNX Technik representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non LYNX Technik supplies; or d) to service a product which has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty servicing the product.
THIS WARRANTY IS GIVEN BY LYNX TECHNIK WITH RESPECT TO THIS PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. LYNX TECHNIK AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. LYNX TECHNIK`S RESPONISIBILITY TO REPAIR AND REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. LYNX TECHNIK AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTAL DAMAGES IRRESPECTIVE OF WHETHER LYNX TECHNIK OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
Reference Manual C DA 5005 Version1.0
Page 4
Regulatory information
Europe
Declaration of Conformity
USA
FCC 47 Part 15
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to the part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense
We LYNX Technik AG Brunnenweg 3 D-64331 Weiterstadt Germany Declare under our sole responsibility that the product
TYPE: C DA 5005
To which this declaration relates is in conformity with the following standards(environments E1-E3): EN 55103-1 /1996
EN 55103-2 /1996 EN 60950 /2001 Following the provisions of 89/336/EEC and 73/23/EEC directives.
Winfried Deckelmann
Weiterstadt, November 2003
Place and date of issue Legal Signature
Reference Manual C DA 5005 Version1.0
Page 5
Contents
Warranty .............................................................................................................. 3
Regulatory information.......................................................................................4
Europe................................................................................................................4
Declaration of Conformity ........................................................................4
USA .....................................................................................................................4
FCC 47 Part 15.............................................................................................4
Getting Started .................................................................................................... 7
Packaging .........................................................................................................7
Product Description .........................................................................................7
Functional Diagram .........................................................................................8
Module Layout .................................................................................................8
Connections ...................................................................................................... 10
Video Connections........................................................................................10
Installation .........................................................................................................11
Settings and Control .........................................................................................12
Control Modes ................................................................................................13
Switch Settings ................................................................................................14
Switch Function Detail .............................................................................15
Factory Preset Condition.........................................................................17
Auto Store ..................................................................................................17
Alarm/LED Status Indicators..........................................................................18
Status Indicators........................................................................................18
Alarm Indicator .........................................................................................18
Locate Function........................................................................................19
Specifications (C DA 5005).............................................................................. 20
Available Options .............................................................................................21
Parts List.............................................................................................................. 21
Service ............................................................................................................... 22
Contact Information ......................................................................................... 23
Reference Manual C DA 5005 Version1.0
Page 6
This page is intentionally left blank
Reference Manual C DA 5005 Version1.0
Page 7
Getting Started
Packaging
The shipping carton and packaging materials provide protection for the module during transit. Please retain the shipping cartons in case subsequent shipping of the product becomes necessary.
Product Description
The C DA 5005 is a 5 channel Monitoring 8 bit video D/A converter designed primarily for broadcast and professional applications.
The Module accepts 5 SDI input signals and provides one CVBS output per channel. The outputs can be switched to a test signal output (color bars).
The C DA 5005 has a variety of features, which includes:
PAL or NTSC operation, auto detect
Internal color bars
Internal 2x over sampling (27MHz)
Local DIP-switches and LED's for control and
status monitoring.
Microprocessor controlled.
Remote control interface.
The module has a built in micro-controller with local controls, status and alarm indicators and well as internal flash ram for storing setups. Any operational parameters configured and stored into the module are recalled when powered up. Remote control and remote status monitoring is possible when using the optional rack controller
CardModules are installed in the series 5000 card frame that can accommodate up to 10 CardModules. All modules are hot swappable and options include full redundant power and a range of controller options.
Reference Manual C DA 5005 Version1.0
Page 8
Functional Diagram
Figure 1 below is the basic functional diagram for the C DA 5005 CardModule.
Figure 1- C DA 5005 Functional Diagram
Module Layout
Figure 2 shows the physical layout of the C DA 5005 CardModule and also the connection panel which is fitted to the rear of the rack.
Reference Manual C DA 5005 Version1.0
Page 9
Figure 2 – Module Layout
Reference Manual C DA 5005 Version1.0
Page 10
Caution
Use static precautions when handling the PCB. Static discharge could result in serious damage to the module.
Connections
Video Connections
The C DA 5005 CardModule is configured with standard 75 Ohm BNC connectors. Connection is self-explanatory. We recommend the use of high quality video cables for digital video connections to reduce the risk of interference or errors due to excessive cable attenuation. Some guidelines for max cable length are shown below.
250m (820 feet) Belden 8281 (270Mbits/s)
Note. Due to the compact design of the connection plate it will be necessary to use a connection tool to secure the BNC video connectors.
Reference Manual C DA 5005 Version1.0
Page 11
Installation
Caution
The CardModule is shipped in a protective anti-static bag. Please take suitable precautions to avoid static discharge onto any part of the PCB or components when handling module or serious damage could result.
Each Card Module is supplied with a rear connection panel and two mounting screws. Please follow the following procedure for installation of the card module into the Series 5000 Card Frame.
a) Select a slot in the card frame where the
CardModule will be located
b) Remove the blank connection panel from the
rear of the rack (if fitted)
c) Install the rear connection panel using the
screws supplied. Do not tighten the screws fully
d) Slide the card module into the card frame and
carefully check the CardModule easily connects to the rear connection plate. The card should fit easily and should not require excessive force to insert, if you feel any resistance, there could be something wrong with the rear connection panel location. Do not try and force the connection. Remove the rear connection panel and check alignment with the CardModule.
e) Insert and remove the CardModule a few times
to ensure correct alignment and then tighten the two screws to secure the rear connection plate
Reference Manual C DA 5005 Version1.0
Page 12
Settings and Control
The C DA 5005 has an integrated micro-controller, which enables the module to be configured and controlled locally using integral 8 position dip switch and the multifunction switch or from remote when using one of the optional controllers and control software.
Once set, all settings are automatically saved in non-volatile internal memory. (Flash ram) The module will always recall the settings used prior to power down.
Figure 3 – Switch and LED locations
Reference Manual C DA 5005 Version1.0
Page 13
Control Modes
There are two modes for the use of the dip switches and the corresponding LEDs:
Channel Status Mode: In this mode the Dip Switches are used to switch the test signal (color bars) ON or OFF for the corresponding channel. The corresponding LED is then GREEN for “Signal Present”, YELLOW for “Test Signal ON” and RED for “Signal Lost”.
Alarm Enable Mode: This mode is used to define which channels are part of the combined alarm indication provided on the single Alarm LED.
Any channels (used or unused) can be configured to be part of the unified alarm reporting.
Example
. If only three of the five channels are being used, with the remaining two disconnected then these channels will report a continuous “input missing” alarm condition and the Alarm LED would be constantly red. Removing unused channels from the alarm reporting will prevent this.
Reference Manual C DA 5005 Version1.0
Page 14
Switch Settings
Below the switch settings for the 8-position dip­switch are defined. Please see the section following the table for more detail on the switch function.
There are two modes for the use of the dip switches and the corresponding LEDs:
1) Channel Status Mode: The Dip Switches switch the test signal (color bars) ON or OFF for the corresponding channel. The corresponding LED is GREEN for “Signal Present”, YELLOW for “Test Signal ON” and RED for “Signal Lost”.
2) Reference Configuration Mode: The Dip switches define which channels form part of the combined alarm reporting for the module. Any channel (used or unused) can be added or removed from the Alarm configuration
CHANNEL STATUS MODE
Switch Setting Function
1 Toggle on-off-on: Re-acquire local control
ON Alarm Enable Mode
2
OFF Channel Status Mode
ON Color bars if no input
3
OFF Black if no input
ON Test signal (color bars) ON for Channel 5
4
OFF Test Signal (color bars) OFF for Channel 5
ON Test signal (color bars) ON for Channel 4
5
OFF Test Signal (color bars) OFF for Channel 4
ON Test signal (color bars) ON for Channel 3
6
OFF Test Signal (color bars) OFF for Channel 3
ON Test signal (color bars) ON for Channel 2
7
OFF Test Signal (color bars) OFF for Channel 2
ON Test signal (color bars) ON for Channel 1
8
OFF Test Signal (color bars) OFF for Channel 1
Reference Manual C DA 5005 Version1.0
Page 15
ALARM ENABLE MODE
Switch Function Detail
All settings are stored in Flash Ram inside the module (see Auto Store section in this manual). Settings will be recalled on power up.
Dip Switch 1
This switch enables local control using the dip­switches. ON enables local control and makes selections on the dipswitch active, and OFF disables local control (locking out any local changes)
Note.
When Switch 1 is initially switched to ON, the static settings currently set on the dip-switches may not reflect the actual configuration stored in the module. This is because all settings can be changed from the remote control system. This overrides the local dip switches regardless of Switch 1 ON/OFF setting. To ensure the module reads the local dip switch settings it is recommended to toggle Switch 1 ON-OFF-ON before making any local changes to the dip switches
.
Switch Setting Function
1 Toggle on-off-on: Re-acquire local control
ON Alarm Enable Mode
2
OFF Channel Status Mode
ON Color bars if no input
3
OFF Black if no input
ON Channel 5 Alarm Enabled
4
OFF Channel 5 Alarm Disabled
ON Channel 4 Alarm Enabled
5
OFF Channel 4 Alarm Disabled
ON Channel 3 Alarm Enabled
6
OFF Channel 3 Alarm Disabled
ON Channel 2 Alarm Enabled
7
OFF Channel 2 Alarm Disabled
ON Channel 1 Alarm Enabled
8
OFF Channel 1 Alarm Disabled
Reference Manual C DA 5005 Version1.0
Page 16
Dip Switch 2
This switch selects either the Channel Status Mode or Reference Configuration Mode as described above. ON = Channel Status Mode, OFF = Alarm Enable Mode
Dip Switch 3
This is used to select what type signal is output for channels with input signal lost. ON selects Color Bars and OFF selects black as output.
Dip Switch 4-8 (CHANNEL STATUS MODE) Switch 4 = Channel 5 … Switch 8 = Channel 1: ON selects test signal color bars OFF selects normal
operation.
Dip Switch 4-8 (ALARM ENABLE MODE) Switch 4 = Channel 5 … Switch 8 = Channel 1: ON Channel alarm is enabled OFF Channel alarm
disabled
Reference Manual C DA 5005 Version1.0
Page 17
Factory Preset Condition
The C DA 5005 is delivered preset for the following mode of operation:
Local control ENABLED
Channel Status Mode
Test Signal Color Bars
Test Signal OFF – Normal operation for all
channels
All channels “Alarm Enabled”
If this is the mode of operation required, then no adjustments are necessary.
Auto Store
If no parameters are changed for 10 seconds then the current settings will be written into flash memory automatically, this can be seen by the alarm LED flashing yellow four times.
Reference Manual C DA 5005 Version1.0
Page 18
Alarm/LED Status Indicators
The C DA 5005 module has six LED indicators, which serve as alarm and status indication for the module (Figure 2 or 3). Function is described below.
Status Indicators
5 Status LEDs are provided on the module edge
Alarm Indicator
There is also a general alarm LED on the lower edge of the module, which can be seen when the rack front cover is fitted. The status of this LED is defined by the alarm enable settings as explained above.
LED OFF indicates power is lost, or there is a power supply fault.
LED 1 – 5 Channel Status Mode
Red Input signal missing
Yellow Test Signal ON
Green Input signal present
LED Color Indication
Green All input signals present
Yellow Test pattern selected (color bars)
Red One or more input signals missing
LED 1 – 5 Alarm Enable Mode
Green Channel Alarm Enabled
OFF Channel Alarm Disabled
Reference Manual C DA 5005 Version1.0
Page 19
Locate Function
For larger systems which may have multiple MiniModules of the same type in a single rack, or multiple rack systems on a large central control system we have added a useful utility which will help to visually locate a suspect module quickly (When used in conjunction with the optional control system and software)
Once the specific module has been selected on the control system there is a locate button on the top of the GUI:
Locate Function in Control System
When Locate is selected the status indicator on the GUI and the module LED`s will flash yellow in the following continuous sequence.
3 short flashes…. Pause…. 3 short flashes …
This uses the alarm LED located on the front of the module and in some cases any channel or status LED`s that may be used in the module.
Use of the locate function will not interfere with the normal operation of the module.
For more details on this feature please check the documentation supplied with the controller software.
Reference Manual C DA 5005 Version1.0
Page 20
Specifications (C DA 5005)
Inputs
Signal
Serial 4:2:2 SMPTE 259M-C (270 Mbit/s)
Standards NTSC-(M/N), PAL (B/D/G/H/I/N/60) Auto detection
Return Loss
>15dB (270MHz)
Cable Equalization 250 m (Belden 8281) Connection
BNC
Impedance 75 Ohms
Outputs
Signal (composite) CVBS Return Loss
>35dB (5,75MHz)
Signal to noise >56dB Connections BNC Impedance 75 Ohms
Operating Modes
Conversion
D/A conversion for SDI-Signals
TV Standard NTSC or PAL (Auto detect) Test Internal Color Bars
Performance
Quantization
8 Bits
Sampling 27 MHz (2x Over sampling)
Electrical Specifications
Operating Voltage + 5VDC Power Consumption 10 W Safety IEC 60950/ EN 60950/VDE 0805
Mechanical
Size 283mm x 78mm Weight Card module 120g, connection panel 50g
Ambient
Temperature 5°C to 40°C Maintaining specifications
-20°C to +70°C Storage
Humidity Max 90% non condensing
Supplied Accessories
Documentation C DA 5005 Reference Manual
Reference Manual C DA 5005 Version1.0
Page 21
Available Options
Below is a list of related products for the C DA 5005 CardModule. Please refer to product brochures or our web site for more detailed information.
Model Description
R FR 5010
Series 5000 Rack Frame (empty) with single power supply
R PS 5010
Redundant power supply for the R FR 5010 Card Frame
R CT 5020
Rack controller for the R FR 5010 Card Frame
R CT 5010
Rack Bus Extension for the R FR 5010 Card Frame. In combination with R CT 5020
Parts List
Due to the very dense design and miniature surface mount technology the module is not field serviceable. The information for a replacement assembly is below.
C DA 5005 CardModule (complete)
Description 5 x SDI to Ana. Video Conv. Model Number C DA 5005 Part Number 6.155.008.221
Sub Assemblies:
C DA 5005 Processing Board only (BS 5002)
Part Number 6.155.005.270
Rear Connection Panel for C DA 5005 (MA3001_B)
Part Number 6.155.001.250
Rear Connection Foil for C DA 5005
Part Number 6.155.008.721
Reference Manual C DA 5005 Version1.0
Page 22
Service
If you are experiencing problems, or have questions concerning your C DA 5005 CardModule please contact your local distributor for assistance.
We offer a fixed cost service exchange program for defective Series 5000 CardModules out of Warranty. Please contact your distributor or check our web site for details on this program.
More detailed information and product updates may be available on our web site:
www.lynx-technik.com
You will also find links to contact us directly for assistance.
Reference Manual C DA 5005 Version1.0
Page 23
Contact Information
Please contact your local distributor; this is your local and fastest method for obtaining support and sales information.
LYNX Technik can be contacted directly using the information below.
Address LYNX Technik AG
Brunnenweg 3 D-64331 Weiterstadt Germany.
Website www.lynx-technik.com
E-Mail info@lynx-technik.com
LYNX Technik manufactures a complete range of high quality modular products for broadcast and Professional markets, please contact your local representative or visit our web site for more product information.
Reference Manual C DA 5005 Version1.0
Page 24
This page is intentionally left blank
Reference Manual C DA 5005 Version1.0
Page 25
Notes
Loading...