Lynx CardModule D VD 5010, CardModule D VD 5000 Reference Manual

Series 5000
© LYNX Technik AG
Brunnenweg 3
D-64331 Weiterstadt
www.lynx-technik.com
Reference Manual
D VD 5010
Reclocking SDI Distribution Amplifier
CardModul
e
Version 1.0
Reference Manual D VD 5010 Version 1.0
Page 2
Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical for any purpose, without express written permission of LYNX Technik AG.
LYNX Technik AG may have patents, patent applications, trademarks, copyrights or other intellectual property rights covering the subject matter in this document. Except as expressly written by LYNX Technik AG, the furnishing of this document does not give you any license to patents, trademarks, copyrights or other intellectual property of LYNX Technik AG or any of its affiliates.
© LYNX Technik AG 2006 all rights reserved
Reference Manual D VD 5010 Version 1.0
Page 3
Warranty
LYNX Technik AG warrants that the product will be free from defects in materials and workmanship for a period of two (2) years from the date of shipment. If this product proves defective during the warranty period, LYNX Technik AG at its option will either repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product.
In order to obtain service under this warranty, customer must notify LYNX Technik of the defect before expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by LYNX Technik, with shipping charges prepaid. LYNX Technik shall pay for the return of the product to the customer if the shipment is within the country which the LYNX Technik service center is located. Customer shall be responsible for payment of all shipping charges, duties, taxes and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure, or damage caused by improper use or improper or inadequate maintenance and care. LYNX Technik shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than LYNX Technik representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non LYNX Technik supplies; or d) to service a product which has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty servicing the product.
THIS WARRANTY IS GIVEN BY LYNX TECHNIK WITH RESPECT TO THIS PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. LYNX TECHNIK AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. LYNX TECHNIK`S RESPONISIBILITY TO REPAIR AND REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. LYNX TECHNIK AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER LYNX TECHNIK OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
Reference Manual D VD 5010 Version 1.0
Page 4
Regulatory information
Europe
Declaration of Conformity
USA
FCC 47 Part 15
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to the part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense
We LYNX Technik AG Brunneweg 3 D-64331 Weiterstadt Germany Declare under our sole responsibility that the product
TYPE: D VD 5010
To which this declaration relates is in conformity with the following standards (environments E1-E3): EN 55103-1 /1996
EN 55103-2 /1996 EN 60950 /2001 Following the provisions of 89/336/EEC and 73/23/EEC directives.
Winfried Deckelmann
Weiterstadt, February 2006
Place and date of issue Legal Signature
Reference Manual D VD 5010 Version 1.0
Page 5
Contents
Warranty .................................................................. 3
Regulatory information........................................... 4
Europe .............................................................................4
Declaration of Conformity.......................................... 4
USA.................................................................................4
FCC 47 Part 15............................................................4
Contents .................................................................. 5
Getting Started........................................................ 7
Packaging........................................................................7
Product Description ........................................................7
Functional Diagram ........................................................8
Module Layout................................................................ 8
Connections.......................................................... 10
Video Connections........................................................10
Installation ............................................................. 11
Settings and Control ............................................. 12
Alarm/LED Status Indicator .................................. 12
Locate Function ........................................................13
Specifications (D VD 5010) .................................. 14
Available Options................................................. 15
Parts List.................................................................. 15
Service ................................................................... 16
Contact Information ............................................. 17
Reference Manual D VD 5010 Version 1.0
Page 6
This page is intentionally left blank
Reference Manual D VD 5010 Version 1.0
Page 7
Getting Started
Packaging
The shipping carton and packaging materials provide protection for the module during transit. Please retain the shipping cartons in case subsequent shipping of the product becomes necessary.
Product Description
The D VD 5010 is a high quality reclocking digital video distribution amplifier designed primarily for broadcast and professional applications.
8 reclocked outputs are provided with auto detection of standard digital video bit rates (143Mbit/s, 177Mbit/s, 270Mbit/s, 360Mbit/s)
The D VD 5010 is part of the 5000 series of CardModules, which offer high quality, modularity and flexibility in a small form factor ideal for applications where space is at a premium.
CardModules are installed in the series 5000 card frame that can accommodate up to 10 CardModules. All modules are hot swappable and Options include full redundant power and a range of controller options.
Reference Manual D VD 5010 Version 1.0
Page 8
Functional Diagram
Figure 1 below is the basic functional diagram for the D VD 5010 CardModule.
Figure 1- D VD 5010 Functional Diagram
Module Layout
Figure 2 shows the layout of the D VD 5010 CardModule and the rear connection panel. Please refer the connections section of this manual for wiring details for the connectors.
Reference Manual D VD 5010 Version 1.0
Page 9
Figure 2 – Module Layout
Caution
Use static precautions when handling the PCB. Static discharge could result in serious damage to the module.
Reference Manual D VD 5010 Version 1.0
Page 10
Connections
Video Connections
The D VD 5010 CardModule is configured with standard 75 Ohm BNC connectors. Connection is self-explanatory. We recommend the use of high quality video cable for digital video connections to reduce the risk of interference or errors due to excessive cable attenuation. Some guidelines for max cable length are shown below.
250m (820 feet) Belden 8281 (270Mbits/s) 150m (492 feet) Belden 8281 (540Mbits/s)
Note. Due to the compact design of the connection plate it will be necessary to use a connection tool to secure the BNC video connectors.
Reference Manual D VD 5010 Version 1.0
Page 11
Installation
Caution
The CardModule is shipped in a protective anti-static bag. Please take suitable precautions to avoid static discharge onto any part of the PCB or components when handling module or serious damage could result.
Each Card Module is supplied with a rear connection panel and two mounting screws. Please follow the following procedure for installation of the card module into the Series 5000 Card Frame.
a) Select a slot in the card frame where the
CardModule will be located
b) Remove the blank connection panel from the
rear of the rack (if fitted)
c) Install the rear connection panel using the
screws supplied. Do not tighten the screws fully
d) Slide the card module into the card frame and
carefully check the CardModule easily connects to the rear connection plate. The card should fit easily and should not require excessive force to insert, if you feel any resistance, there could be something wrong with the rear connection panel location. Do not try and force the connection. Remove the rear connection panel and check alignment with the CardModule.
e) Insert and remove the CardModule a few times
to ensure correct alignment and then tighten the two screws to secure the rear connection plate
Reference Manual D VD 5010 Version 1.0
Page 12
Settings and Control
The D VD 5010 has an integrated micro-controller, which enables the module to be controlled locally or from remote when using one of the optional controllers and control software.
The D VD 5010 has a fixed configuration, signal presence detection is indicated via the Alarm LED on the front card edge or via the LYNX control system when using one of the optional controllers and control software.
Alarm/LED Status Indicator
The D VD 5010 module has an integral LED indicator, which serve as alarm indication for the module. This is visible through the card frame front cover and provides a general indication of the module status.
LED OFF indicates power is lost, or there is a power supply fault.
LED Color Indication
Green Signal Present (locked) Red Input signal lost
Reference Manual D VD 5010 Version 1.0
Page 13
Locate Function
For larger systems which may have multiple cards of the same type in a single rack, or multiple rack systems on a large central control system we have added a useful utility which will help to visually locate a suspect module quickly (When used in conjunction with the optional control system and software)
Once the specific module has been selected on the control system there is a locate button on the top of the GUI:
Locate Function in Control System
When Locate is selected the status indicator on the GUI and the alarm LED will flash yellow in the following continuous sequence.
3 short flashes…. Pause…. 3 short flashes …
Use of the locate function will not interfere with the normal operation of the module.
For more details on this feature please check the documentation supplied with the controller software.
Reference Manual D VD 5010 Version 1.0
Page 14
Specifications
(D VD 5010)
Inputs
Signal 1 Serial Digital Video. SMPTE 259M-C Input Impedance 75 Ohms Input level 0.8V p-p Return loss > 15dB (270MHz) Connection BNC
Outputs
Signal 8 Serial Digital Video. SMPTE 259M-C Output Impedance 75 Ohms Output Level 0.8V p-p nom. Return loss > 15dB (270 Mbit/s) Connection BNC
Performance
Cable Equalization Up to 250m using Belden 8281 (270Mbit/s) Jitter < 0.2 UI
Status Monitoring (LED) Signal presence
Electrical Specifications
Operating Voltage + 5VDC Power Consumption 2 W Safety IEC 60950/ EN 60950/VDE 0805
Mechanical
Size 283mm x 78mm Weight Card module 120g, connection panel 50g
Ambient
Temperature 5°C to 40°C Maintaining specifications Humidity Max 90% non condensing
Supplied Accessories
Documentation D VD 5010 Reference Manual
Reference Manual D VD 5010 Version 1.0
Page 15
Available Options
Below is a list of related products for the D VD 5010 CardModule. Please refer to product brochures or our web site for more detailed information.
Model Description
R FR 5010
Series 5000 Rack Frame (empty) with single power supply
R FR 5011
Series 5000 Rack Frame (empty) with single power supply and additional fans in the front cover
R PS 5010
Redundant power supply for the R FR 5010 Card Frame
R CT 5020
Rack controller for the R FR 5010 Card Frame
R CT 5030
Master controller with TCP/IP interface for the R FR 5010 Card Frame
R CT 5010
Rack Bus Extension for the R FR 5010 Card Frame. In combination with R CT 5020/5030
Parts List
Due to the very dense design and miniature surface mount technology the module is not field serviceable. The information for a replacement assembly is below.
D VD 5010 CardModule (complete)
Description Recl. SDI Distribution Amplifier Model Number D VD 5010 Part Number 6.155.005.010
Sub Assemblies: D VD 5010 Processing Board only. (BS 5033_A)
Part Number 6.155.004.391
Rear Connection Panel for D VD 5010 (MA5001_B)
Part Number 6.155.008.371
Reference Manual D VD 5010 Version 1.0
Page 16
Service
If you are experiencing problems, or have questions concerning your D VD 5010 CardModule please contact your local distributor for assistance.
We offer a fixed cost service exchange program for defective Series 5000 CardModules out of Warranty. Please contact your distributor or check our web site for details on this program.
More detailed information and product updates may be available on our web site:
www.lynx-technik.com
You will also find links to contact us directly for assistance.
Reference Manual D VD 5010 Version 1.0
Page 17
Contact Information
Please contact your local distributor; this is your local and fastest method for obtaining support and sales information.
LYNX Technik can be contacted directly using the information below.
Address LYNX Technik AG
Brunnenweg 3 D-64331 Weiterstadt Germany.
Website www.lynx-technik.com
E-Mail info@lynx-technik.com
LYNX Technik manufactures a complete range of high quality modular products for broadcast and Professional markets, please contact your local representative or visit our web site for more product information.
Reference Manual D VD 5010 Version 1.0
Page 18
Notes
Loading...