Lynx CardModule C AD 5131 Reference Manual

Series 5000
© LYNX Technik AG
Brunnenweg 3
D-64331 Weiterstadt
www.lynx-technik.com
Reference Manual
C AD 5131
Analog Video to SDI Conv. & Line Synchronizer
CardModule
Analog Video to SDI Conv.
C AD
5131
Analog Video to SDI Conv. & Line Synch
C AD 5131
REF in
REF loop
Y 1 in
Y 2 in
U/C 1 in
U/C2 in
V 1 in
V 2 in
SDI out 1
SDI out 2
LYNX Technik AG
5 1 3
1
Version 1.1
Reference Manual C AD 5131 Version1.1
Page 2
Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical for any purpose, without express written permission of LYNX Technik AG.
LYNX Technik AG may have patents, patent applications, trademarks, copyrights or other intellectual property rights covering the subject matter in this document. Except as expressly written by LYNX Technik AG, the furnishing of this document does not give you any license to patents, trademarks, copyrights or other intellectual property of LYNX Technik AG or any of its affiliates.
© LYNX Technik AG 2003 all rights reserved
Reference Manual C AD 5131 Version1.1
Page 3
Warranty
LYNX Technik AG warrants that the product will be free from defects in materials and workmanship for a period of two (2) year from the date of shipment. If this product proves defective during the warranty period, LYNX Technik AG at its option will either repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product.
In order to obtain service under this warranty, customer must notify LYNX Technik of the defect before expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by LYNX Technik, with shipping charges prepaid. LYNX Technik shall pay for the return of the product to the customer if the shipment is within the country which the LYNX Technik service center is located. Customer shall be responsible for payment of all shipping charges, duties, taxes and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure, or damage caused by improper use or improper or inadequate maintenance and care. LYNX Technik shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than LYNX Technik representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non LYNX Technik supplies; or d) to service a product which has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty servicing the product.
THIS WARRANTY IS GIVEN BY LYNX TECHNIK WITH RESPECT TO THIS PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. LYNX TECHNIK AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. LYNX TECHNIK`S RESPONISIBILITY TO REPAIR AND REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. LYNX TECHNIK AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTAL DAMAGES IRRESPECTIVE OF WHETHER LYNX TECHNIK OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
Reference Manual C AD 5131 Version1.1
Page 4
Regulatory information
Europe
Declaration of Conformity
USA
FCC 47 Part 15
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to the part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense
We LYNX Technik AG Brunnenweg 3 D-64331 Weiterstadt Germany Declare under our sole responsibility that the product
TYPE: C AD 5131
To which this declaration relates is in conformity with the following standards: EN 55103-1 /1996
EN 55103-2 /1996 EN 60950 /1997 Following the provisions of 89/336/EEC and 73/23/EEC directives.
Winfried Deckelmann
Weiterstadt, June 2003
Place and date of issue Legal Signature
Reference Manual C AD 5131 Version1.1
Page 5
Contents
Warranty .............................................................................................................. 3
Regulatory information.......................................................................................4
Europe................................................................................................................4
Declaration of Conformity ........................................................................4
USA .....................................................................................................................4
FCC 47 Part 15.............................................................................................4
Contents...............................................................................................................5
Getting Started .................................................................................................... 7
Packaging .........................................................................................................7
Product Description .........................................................................................7
Functional Diagram .........................................................................................8
Module Layout .................................................................................................8
Connections ...................................................................................................... 10
Video Connections........................................................................................10
Installation .........................................................................................................11
Settings and Control .........................................................................................12
Multi Function Switch .....................................................................................13
Using the Local Display Menus.....................................................................14
Navigation .................................................................................................14
Local Adjustments Available ..................................................................14
Menu Structure ...............................................................................................15
Factory Preset Condition.........................................................................20
Auto Store ..................................................................................................20
Alarm/LED Status Indicators............................................................................. 21
Status Indicators........................................................................................21
Alarm Indicator .........................................................................................21
Locate Function........................................................................................22
Specifications (C AD 5131)..............................................................................23
Available Options .............................................................................................24
Parts List.............................................................................................................. 24
Service ............................................................................................................... 25
Contact Information ......................................................................................... 26
Reference Manual C AD 5131 Version1.1
Page 6
This page is intentionally left blank
Reference Manual C AD 5131 Version1.1
Page 7
Getting Started
Packaging
The shipping carton and packaging materials provide protection for the module during transit. Please retain the shipping cartons in case subsequent shipping of the product becomes necessary.
Product Description
The C AD 5131 is a high performance 12 Bit Video A/D Converter for component analog YUV and S­video signals and is designed primarily for broadcast and professional applications.
One out of two sets of input signals can be selected. The input Architecture is differential to assure optimal resistance against distortion. 525/625 Input detection is automatic. Either an external loop-through reference or the internal rack reference (black burst signal) can be used to line­synchronize the two SDI outputs.
The C AD 5131 features a wide range of available adjustments (via optional Rack Controller) basic adjustments are possible using via the local multi­function switch and integrated display.
CardModules are installed in the series 5000 card frame that can accommodate up to 10 CardModules. All modules are hot swappable and Options include full redundant power and a range of controller options.
Reference Manual C AD 5131 Version1.1
Page 8
Functional Diagram
Figure 1 below is the basic functional diagram for the C AD 5131 CardModule.
Figure 1- C AD 5131 Functional Diagram
Module Layout
Figure 2 shows the physical layout of the C AD 5131 CardModule and also the connection panel which is fitted to the rear of the rack.
Multi Function
Switch
MUX
Genlock
A/D
Conversion
Decoder
(S-Video)
Selectable
Chroma / Luma
Filter
Line
Synchronizer
SDI out 1
SDI out 2
PAR
SER
Micro-Controller
Alarm / Staus LEDs
UP
DN
ENTER
Ref IN
REF Loop
Y 1 in
Control
Rack Reference
Test
Signal
U/C 1 in
V 1 in
Y 2 in
U/C 2 in
V 2 in
Reference Manual C AD 5131 Version1.1
Page 9
Figure 2 – Module Layout
PCB Layout
Rear Connection Panel
PCB Front View
LED 1
LED 2
LED 3 (Alarm)
UP
DN
Press
for
ENTER
5111
LED 4
CVBS to SDI Conv.
Matrix Display
Analog Video to SDI Conv. & Line Synch
C AD 5131
REF in
REF loop
Y 1 in
Y 2 in
U/C 1 in
U/C2 in
V 1 in
V 2 in
SDI out 1
SDI out 2
LYNX Technik AG
Analog Video to SDI Conv.
C AD
5131
5
1 3
1
Reference Manual C AD 5131 Version1.1
Page 10
Caution
Use static precautions when handling the PCB. Static discharge could result in serious damage to the module.
Connections
Video Connections
The C AD 5131 CardModule is configured with standard 75 Ohm BNC connectors. Connection is self-explanatory. We recommend the use of high quality video cable for digital video connections to reduce the risk of interference or errors due to excessive cable attenuation. Some guidelines for max cable length are shown below.
250m (820 feet) Belden 8281 (270Mbits/s)
Note. Due to the compact design of the connection plate it will be necessary to use a connection tool to secure the BNC video connectors.
Reference Manual C AD 5131 Version1.1
Page 11
Installation
Caution
The CardModule is shipped in a protective anti-static bag. Please take suitable precautions to avoid static discharge onto any part of the PCB or components when handling module or serious damage could result.
Each Card Module is supplied with a rear connection panel and two mounting screws. Please follow the following procedure for installation of the card module into the Series 5000 Card Frame.
a) Select a slot in the card frame where the
CardModule will be located
b) Remove the blank connection panel from the
rear of the rack (if fitted)
c) Install the rear connection panel using the
screws supplied. Do not tighten the screws fully
d) Slide the card module into the card frame and
carefully check the CardModule easily connects to the rear connection plate. The card should fit easily and should not require excessive force to insert, if you feel any resistance, there could be something wrong with the rear connection panel location. Do not try and force the connection. Remove the rear connection panel and check alignment with the CardModule.
e) Insert and remove the CardModule a few times
to ensure correct alignment and then tighten the two screws to secure the rear connection plate
Reference Manual C AD 5131 Version1.1
Page 12
Settings and Control
The C AD 5131 has an integrated micro-controller, which enables the module to be configured and controlled locally using the multifunction switch and 4 character dot matrix display, or from remote when using one of the optional controllers and control software.
Once set, all settings are automatically saved in non-volatile internal memory. (Flash ram) The module will always recall the settings used prior to power down.
Figure 3 – Switch and Display Location
Analog Video to SDI Conv.
C AD
5131
Multifunction
Switch
Matrix Display
5
1 3
1
Reference Manual C AD 5131 Version1.1
Page 13
Multi Function Switch
The CardModule is equipped with a multi-function switch located on the front bottom edge of the card (refer to figure 3)
Figure 4 – Switch Operation
Up Down
Enter
Switch Operations
Multi-function Switch
Side Front
Reference Manual C AD 5131 Version1.1
Page 14
Using the Local Display Menus
Making local adjustments to the module is done using the multifunction switch and the integrated 4­character dot matrix display (figure 3). The menu system is layered, and navigation through the system is done using the UP and DOWN functions of the switch. ENTER is used to move between menu levels and also enter a selection.
Navigation
Local Adjustments Available
All of the critical adjustments to the module are accessible using the local display and multi ­function switch, these include:
Input Signal A/B select
Input YCrCb – YC mode select
External / Rack Internal line sync reference
select
Analog input filter on/off
Genlock mode
Luma-/ chroma filter settings
Auto-/ manual gain control
Test signal select
A set of extended adjustments is possible when using a controller option and LYNX control software. Adjustments (in addition to the basic adjustments above) include:
Switch Function Operation
UP Move UP within a level DOWN Move down within a level ENTER Change levels / Make selection
Reference Manual C AD 5131 Version1.1
Page 15
Adjustable Luma / chroma peaking filters
Adjustable Coring function
Adjustable Contrast, Saturation, Brightness and
Hue
Analog / digital clamp disable
Automatic Gain Control mode reference select
Luma / Chroma shaping filter for YC (S-Video)
mode
Maximum IRE adjust
Menu Structure
The Menu structure is defined in the next table, and should be used when navigating through the system.
Notes / Tips.
ENTER moves between Levels
UP/DOWN moves between items within the level
When you enter a new setting the system will jump back one level in the menu system.
The “back” selection in the menu structure will take you back one level when selected.
When an item is selected which has several setting possibilities the first value displayed will be the value currently stored in the system. The order of the available settings for any menu item in the table supplied does not represent the order he settings will actually be displayed.
If left unattended, the menu will default to the root display after a preset timeout.
Reference Manual C AD 5131 Version1.1
Page 16
5 5
1 1
ROOT LEVEL 1 LEVEL 2 LEVEL 3 COMMENTSLEVEL 4
"Normal" Root display on module = Module type
Input signal select
Analog filter selection
Video standard selection
a c kb
N I
1 G S
N AIN BIa c k
b
1 L TF
1 3 1 5
F FO
L A TFN HEa c k
b
T DS
2 55
U T O A
2 56
a c k b
O M PCCYa c k
b
Mode Select
COMP = Y,Pr,Pb Component Analog
YC = Y / C seperated (S-Video)
O D E M
NOTE. For automatic mode if input video and
the reference signal are different standards
then the reference input will be ignored.
Reference Manual C AD 5131 Version1.1
Page 17
Clamp time constant selection
L M P C
L O WSa c kb
A S T F
EXT = set reference to external input
INT = set reference to rack reference
OFF = set reference to video input with minimum
delay (3.6us)
Enter line delay
Enter pixel delay
0 ..... 1715 for 525
0 ......1727 for 625
automatic wrap to next lne when limit reached
Select luminance filter. (1...18) default 18
O Q L
QM
a c k
b
S N C
L
X TEN TIF FOa c k
b
L A Y
D
I N E
L
I X L P
a c k b
a c kb
0 0 0
0
0 0 0
0
E N L G
I D V
I L T F
U M L
0 0 0 0
I QH
LO Q = "Video Tracking Mode" for inputs with
poor signal quality. No line synch function.
M Q = For poor input signal quality with
timebase and line synch functions.
HI Q = VCXO mode, for inputs with high quality
signals.
Reference Manual C AD 5131 Version1.1
Page 18
Select chroma bandwidth. Default = 3.0M
0 LC
. 7 M0
. 3 M1
. 5 M1. 8 M1
. 2 M 2
a c k b
Set luminance gain:
AUTO = based on sync tip amplitude
MAN = Enter required gain value
Set Chroma gain:
AUTO = based on Luma gain
MAN = Enter required gain value
A I NG
U T OAA NM
a c kbU T OAA NMa c k
b
a c k b
0 0 0 0
0 0 0 0
a c k b
U M L
0 L
C
. 0 M
3
Reference Manual C AD 5131 Version1.1
Page 19
Select test signal
BAR = Color Bars
BLK = Black
EQ = Equaliser pathological test signal
PLL = PLL pathological test signal
Select test signal standard
Restore factory defaults
T D
S
a c kb
a c k b
2 56
2 5 5
A RB
L KBQE
L LPF FO
a c k b
O N
E S
Y
a c k b
E S TT
S E T R
L C TS
Reference Manual C AD 5131 Version1.1
Page 20
Factory Preset Condition
The C AD 5131 is delivered programmed and preset for the following mode of operation:
Input Input A Analog Filter OFF Standard Auto Clamp Fast Genlock HI Q Reference External Line delay 0000 Pixel delay 0000 Lum filter 18 Chroma filter 3.0M Lum gain Auto Chroma gain Auto Test Signal Bars
If this is the mode of operation required, then no adjustments are necessary.
These settings can be recalled at any time by selecting reset from the menu system.
Auto Store
If no parameters are changed for 10 seconds then the current settings will be written into flash memory automatically, this can be seen by the alarm LED flashing yellow four times.
Reference Manual C AD 5131 Version1.1
Page 21
Alarm/LED Status Indicators
The C AD 5131 module has integral LED indicators, which serve as alarm and status indication for the module. Function is described below.
Status Indicators
3 status LED`s are provided on the front edge of the module, LED 1, LED 2. LED 4 (figure 2)
Alarm Indicator
There is also a single alarm LED on the lower edge of the module LED 3. This is visible through the card frame front cover and provides a general indication of the module status.
LED OFF indicates power is lost, or there is a power supply fault.
LED Color Indication
Green Input Present
1
Red No Input Green PLL locked
2
Red PLL unlocked Green 525 Mode
4
Yellow 625 mode
LED Color Indication
Green Signal present and PLL locked Yellow Test Signal Selected Red No input signal, PLL unlocked
Reference Manual C AD 5131 Version1.1
Page 22
Locate Function
For larger systems which may have multiple cards of the same type in a single rack, or multiple rack systems on a large central control system we have added a useful utility which will help to visually locate a suspect module quickly (When used in conjunction with the optional control system and software)
Once the specific module has been selected on the control system there is a locate button on the top of the GUI:
Locate Function in Control System
When Locate is selected the status indicator on the GUI and the alarm LED will flash yellow in the following continuous sequence.
3 short flashes…. Pause…. 3 short flashes …
Use of the locate function will not interfere with the normal operation of the module.
For more details on this feature please check the documentation supplied with the controller software.
Reference Manual C AD 5131 Version1.1
Page 23
Specifications (C AD 5131)
Inputs (video)
Signal Y Cr Cb or Y C (S-Video), one out of two inputs
selectable. AC coupled, differential inputs. Sync on Y Input Impedance 75 Ohms Connection BNC
Inputs (ext reference)
Signal
Composite sync (black burst) Input Impedance 75 Ohms Connection BNC
Outputs
Signal 2 x serial 4:2:2 SMPTE 259M-C (270 Mbps) with EDH Output Level 0.8V p-p Jitter < 0.2UI Return loss > 15dB Connection BNC Output Impedance 75 Ohms
Operating Modes
Y Cr Cb
A/ D conversion for component Signals
Y/ C A/ D conversion for Chroma/ Luma separated signals Test Built in Color Bar, PLL pathological, EQ pathological,
black flat field
Performance
Quantization 12 Bits for Luma and Chroma Frequency Response ± 0,15 dB ...5,5 MHz for Luma Sampling 27 MHz (2 x over sampling) Filters Selectable Chroma filters (3 line, adaptive), various
Luma / Chroma filters Processing Delay Adjustable 1..3 line delay, or minimum 3,6 us. S/N Ratio < -61 dB (unweighted to 5,75 MHz)
Electrical Specifications
Operating Voltage + 12 VDC Power Consumption 7 W Safety IEC 950/ EN 60950/VDE 0805
Mechanical
Size 283mm x 78mm Weight Card module 120g, connection panel 50g
Ambient
Temperature 5°C to 35°C Maintaining specifications Humidity Max 80% non condensing
Supplied Accessories
Documentation C AD 5131 Reference Manual
Reference Manual C AD 5131 Version1.1
Page 24
Available Options
Below is a list of related products for the C AD 5131 CardModule. Please refer to product brochures or our web site for more detailed information.
Model Description
R FR 5010
Series 5000 Rack Frame (empty) with single power supply
R PS 5010
Redundant power supply for the R FR 5010 Card Frame
R CT 5020
Rack controller for the R FR 5010 Card Frame
R CT 5010
Rack Bus Extension for the R FR 5010 Card Frame. In combination with R CT 5020
Parts List
Due to the very dense design and miniature surface mount technology the module is not field serviceable. The information for a replacement assembly is below.
C AD 5131 CardModule (complete)
Description Ana. Vid. to SDI Converter Model Number C AD 5131 Part Number 6.155.008.210
Sub Assemblies:
C AD 5131 Processing Board only (BS5018 C)
Part Number 6.155.007.320
Rear Connection Panel for C AD 5131 (MA5019)
Part Number 6.155.007.215
Reference Manual C AD 5131 Version1.1
Page 25
Service
If you are experiencing problems, or have questions concerning your C AD 5131 CardModule please contact your local distributor for assistance.
We offer a fixed cost service exchange program for defective Series 5000 CardModules out of Warranty. Please contact your distributor or check our web site for details on this program.
More detailed information and product updates may be available on our web site:
www.lynx-technik.com
You will also find links to contact us directly for assistance.
Reference Manual C AD 5131 Version1.1
Page 26
Contact Information
Please contact your local distributor; this is your local and fastest method for obtaining support and sales information.
LYNX Technik can be contacted directly using the information below.
Address LYNX Technik AG
Brunnenweg 3 D-64331 Weiterstadt Germany.
Phone + 49 (0) 6150 1817 0
Fax + 49 (0) 6150 1817 10
Website www.lynx-technik.com
E-Mail info@lynx-technik.com
LYNX Technik manufactures a complete range of high quality modular products for broadcast and Professional markets, please contact your local representative or visit our web site for more product information.
Reference Manual C AD 5131 Version1.1
Page 27
Notes
Loading...