LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
ADP-15M
Class D Powered (bi-amplified)
Integrated Digital Processing
Internal temperature control
Electronic protection
High quality components
Online monitoring available

Manufacturer
CB SCHEME, IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION
OF ELECTRICAL EQUIPMENT
CE CERTIFICACTION, EUROPEAN PRODUCT
ADP-15M stage monitor
LYNX Pro Audio S.L.
Calle 7 - Pol. Ind. Picassent
E-46220 Picassent (Valencia)
This user manual is property of Lynx Pro Audio S.L. Any reproduction of this manual, by any means is strictly prohibited.
Copyright 2012. All rights reserved.

LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
ADP-15M
CONTENTS
- SAFETY PRECAUTIONS 5
- CABINET INTRO
SPECIFICATIONS 6
BACK PANEL 7
CONNECTORS AND CONNECTIONS 7
- CONFIGURING THE CABINET DSP OPTIONS
PRESET LIST 9
FIR FILTERS 9
CONFIGURATION PANEL 10
SELECT AND RUN PRESET 10
- ONLINE CONTROL SYSTEM 11
- CONFIGURING ETHERNET 12
- GUARANTEE 18

LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
ADP-15M
Before starting to use this device, please read this instruction manual carefully.
Keep these instructions in the place where the equipment will be used and with easy access to them.
- Electrical appliance.
The exclamation mark within a triangle identifies the presence of electricity. Use the system carefully
without wet hands or feet. Avoid installing the speaker in wet or excesivelly humid places. Do not place
material that contains liquid on or near the unit. Avoid dripping or splashing water or any liquid over the
unit. Regularly check the condition of the cables and make sure these are not being walked on or
pinched. Connect the speaker to bipolar, earthed mains. The mains plug must be connected to the
appropriate protection (fuse or breaker). Connection to any other type of mains could result in an
electrical shock and violate local electrical codes. CAUTION: DO NOT CONNECT OR DISCONNECT
THE AC POWER CONNECTORS UNDER LOAD.
- Heavy equipment.
Apply back protection when using the system. Avoid loading and unloading at heights.
- Electrical shock risk.
The diagonal mark within a triangle identifies the presence of dangerous voltage.
Do not open or handle the interior of the box. These parts are not to be adjusted by the user. For
maintenance and/or repair please go to an authorized service centre.
In order to reduce the risk of electric shock, disconnect from AC before plug in or unplugging Audio
signal cables. Reconnect to AC only if all signal connections are made and secured.
Never manipulate the ground type plug provided.
The AC mains plugs should always remain accessible for operation.
Unplug the loudspeaker during storms or when it’s being used for a long time.
- Hearing damage risk.
These systems can reproduce large quantities of sound pressure which can damage hearing. Take
precautions if you are going to be near them for extended amounts of time and do not get too close.
- Hanging – Flying.
Do not hang the cabinets from the handles or from any other part other than the designated hanging
point. When flying this system please observe the technical and “Lynx On Stage” software data carefully.
Never exceed the maximum safe working loads or ignore the instructions included within this manual.
Use Only flying accessories provided by Lynx Pro Audio S.L.
Rigging must be always carried out by professionals.
- Delicate Material.
Please ensure no foreign object or water enters the speaker. Only clean the unit with dry cloths. Do not
use solvents.
-Overheating – Fire risk.
To reduce the risk of the speaker over heating, avoid direct contact with sunlight. Avoid placing the unit
close to heat inducing objects such as radiators. Do not cover the equipment in use and do not block
any ventilation openings. Do not put naked flame, such as lighted candles, close or on top of the unit.
- Electromagnetic and interferente emissions.
Avoid placing objects which through electromagnetic waves can damage the unit, such as mobile
phones, lap tops, magnetic strip cards etc.
This system complies with normatives EN 55103-1 (1)
EN 55103-2 (2)
(1) This device may not cause harmful interferences.
(2) This device may receive interference including interferences that may cause undesired working.
-IMPORTANT NOTE.
This Equipment must be used in accordance with these instructions and by trained professional
personnel only.
This equipment should not be used in places with extreme tropical climates. Don’t expose this apparatus
to extreme humidity and or temperature values.
5

LYNX Pro Audio S.L. - Valencia, Spain - www.lynxproaudio.com -info@lynxproaudio.com
ADP-15M
INTRODUCTION
To facilitate, correct and reliable use of the stage monitor ADP-15M we have designed this instruction manual. Please
read the manual carefully before proceeding to install the system.
Please observe the technical data carefully and do not ignore the instructions included within this manual.
SPECIFICATIONS:
FREQUENCY RANGE 60Hz -20KHz
FREQUENCY RESPONSE 70Hz- 18KHz ± 3dB
HORIZONTAL COVERAGE 90º
VERTICAL COVERAGE 90º
MAX SPL 130 dB/ 133dB peak 1w@ 1m
CROSSOVER 1500 Hz
TRANSDUCERS LF/MF: 15" Coaxial Custom Neod.+Nomex Cone
HF: 1.4" Neodimium driver + Titanium diaphragm
SHAPE Trapezoidal
POWER AMPLIFIER 1500W Class D with Switching Power supply
750W Low/Mid + 750W High
DSP Internal Lynxlprocessor DSPB-22® with FIR filters
CABINET ADJUSTMENT Back panel LCD screen
INTERNAL CONTROLS Temperature sensor / Fan Speed control
SIGNAL CONNECTION NEUTRIK connectors XLR Male Input
XLR Female Loop Thru
CONTROL CONNECTIONS USB (DSP programming),
ETHERNET* (Online Monitoring System OMS®)
AC POWER 230v / 115v selectable. 50/60 Hz 5A
AC CONNECTIONS 16A NEUTRIK POWERCON with Looping Output
CONSTRUCTION 15 mm Premium Birch plywood
FINISH High resistant water-based black paint
FRONT DESIGN Black antirust steel grille
DIMENSIONS (H x W x D) 434 x 620 x 618 mm
WEIGHT 26 Kg (57 lbs)
* Ethernet connection is optional.
6